13
ENGLISH
GB
8.6.
Installation of the appliance in a line
To fix the appliance in a line (neighbouring) follow
the steps:
Dismantle the control panel, and remove the cast
iron frame from the chimney if necessary.
Apply the sealing tape (
A
) onto the joining sides.
Place the appliances next to each other and in a
horizontal position (by adjusting the feet).
Connect the appliances with the joining elements.
8.7.
Gas supply (service technician)
The appliance has been checked by the
manufacturer for the type of gas shown on the
rating plate. If a different type of gas is used,
follow these guidelines.
1.
Close the gas valve (A)
2.
Replace the burner nozzle (see relevant
chapter)
3.
Replace the nozzle of the ignition flame (see
relevant chapter)
4.
Set a minimum value on the burner gas valve
(see relevant chapter)
5.
If necessary, check the air supply.
6.
Remove the sticker from the rating plate and
apply a new sticker which includes the used
gas type (item 4 of the rating plate).
8.8.
Inspection (service technician)
Before starting the appliance the installation
check-up should be run to evaluate the working
conditions of every single component and
recognize any errors.
It is recommended to run the following check-ups:
1.
Open the gas valve and check the tightness of
connections;
2.
Check whether the igniter starts and burns
properly.
3.
Check and adjust, if necessary, the gas
pressure and flow rate in Max and Min
positions (see chapter)
4.
Check
whether
the
safety
thermostat
operates properly.
5.
Check gas connection for gas leaks.
A
A
B
C
C
ID 12