7.
TROUBLESHOOTING
The information below is provided to recognize
and repair any failures that may occur when
operating the appliance.
Some of the failures can be repaired by the user,
others require thorough specialist knowledge.
Such problems may be solved exclusively by the
qualified personnel.
Problem
Cause
Solution
Gas smell.
The smell is sometimes
released when extinguishing
the flame.
Close the gas cut-off valve and
ventilate the room.
The ignition flame does not start.
The spark ignition does not
work.
Check operation of ignition
appliances. Ignite the flame
manually.
Contact the service company.
Air in the pipes in connection
with the long downtime.
The igniting flame continuously
goes out.
The thermal element is not
sufficiently hot.
Extend the ignition process.
Yellow flame.
The burner is contaminated or
moist.
Clean the burner and leave for
drying.
When problem persists contact
the service company.
It is difficult to rotate the burner
control knob.
Damaged valve.
Contact the service company.
8.
INSTALLATION
8.1.
Packaging and unpacking
During unloading and when installing the
appliance follow the information from the
manufacturer placed directly on the packaging
and in this manual.
To lift and transport the product plan to use a fork
lift or stacker, and pay attention to even weight
distribution to avoid a risk of tilting of the
packaging (avoid excessive incline!).
While using the elevator pay
attention to the gas supply hoses and
position of feet.
The packaging consists of the carton packaging
and wooden pallet. There are symbols printed on
the carton packaging that according to the
international
agreements
inform
about
the
regulations to follow when loading and unloading,
transporting and storing the appliance.
When collecting the goods check if the packaging
is complete and has not been damaged during
transport.
Any damage should be immediately reported to
the shipping company.
THIS
SIDE UP
CAUTION
GLASS
KEEP DRY