Installation and operation
24 / 32
610842
EN
5.4.3
Settings Changes
The microwave unit's setting may be, if needed, adjusted/changed. In order not to
switch accidentally to programming mode during regular operation, it may be called
up only when the door is open.
Programming Mode Selection
1. Press STOP key once and hold.
The 'Code---' will be shown in the digital display (mode option).
Function Selection
1. Press one of the numpad keys (1
–0).
The digital display will display the selected number.
2. Press the numpad key again to change the setting.
Saving
1. After selecting the program press START key to save settings.
Key
Function
Message
User option
(Default factory settings in bold)
1
End of
thermal
processing
signal
Code 1-0
3 long acoustic signals for 3 seconds
Code 1-1
1 short and 1 long acoustic signal for 3
seconds
Code 1-2
3-second acoustic signal
Code 1-3
3 fast acoustic signals for 3 seconds
Code 1-4
5 fast acoustic signals for 3 seconds
2
Acoustic
signal ON /
OFF
Code 2-1
Block acoustic signal, when a numpad key
is pressed
Code 2-0
Allows acoustic signal, when a numpad key is
pressed