background image

OPERATION

2

NOTE: 

Do not attempt to operate this appliance until you have read and thoroughly understand all safety 

information in this manual and all assembly is complete and leak tests are routinely performed. 

BEFORE LIGHTING THE HEATER

1. 

Heater should be thoroughly inspected before each use by a qualified technician, When re-lighting the 

heater, always wait at least 5 minutes.  

 

 

 

 

  

 

 

 

 

 

2.

 Inspect the hose assembly for evidence of excessive abrasion, cuts or wear. Suspected areas should be 

leak tested. If the hose leaks it must be replaced prior to operation. Use only replacement hoses specified 

by 

the 

manufacturer. 

    

LIGHTING THE HEATER:    

 

 

NOTE: 

For initial start or after any cylinder change, 

hold the knob in for two minutes to purge air from 

the gas lines before proceeding.  

 

 

1. Turn the control knob to the OFF position. 

2. Fully open the LPG tank valve.  

 

 

3.  Push  in  and  turn  the  control  knob  to  the  HI 

location     

 

 

 

 

 

4. Keep the control knob depressed and push the 

RED  igniter  button  simultaneously.  Push  several 

times to ignite the main burner. Repeat  until the 

burner  ignites  and  keep  the  control  knob  fully 

depressed for an additional 30 seconds after the 

burner ignites, then release the knob.  

 

5.  To  increase  the  flame,  turn  the  control  knob 

clockwise towards HI. To decrease the flame turn 

the  control  knob  counter-clockwise  towards  LO 

position.     

 

 

 

 

6.  To 

turn  the  appliance  off,  depress  the  control  knob 

and turn clockwise to the OFF position.      

7. Wait at least 5 minuted for attempting to re-light 

the  heater.  8.  Turn  the  LPG  tank  valve  to  OFF  or 

closed. If you experience any ignition problems, see 

the TROUBLESHOOTING section of this manual.  

       

CAUTION: 

Avoid  inhaling  fumes  emitted  from 

the heater’s first use. Both smoke and odor from 

burning  of  oils  used  in  the  manufacturing  will 

appear.  Both  smoke  and  odor  will  dissipate  after 

approximately 30 minutes, The heater should not 

product thick black smoke. 

Summary of Contents for 96053C

Page 1: ...ONS ASSEMBLY OPERATION INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL OR THE MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO SERIAL NUMBER FOR...

Page 2: ...Minimum heater clearances from combustibles is three feet from the sides and two feet from the top of the heater NEVER operate this device with the protected heating element opening blocked Keep this...

Page 3: ...device WARNING This product is fueled by propane gas Propane gas is invisible odorless and flammable An odorant is normally added to help detect leaks and can be described as a rotten egg smell The od...

Page 4: ...PACKAGE CONTENTS 1...

Page 5: ...insert 2 medium bolts through the holes and finger tighten Confirm that the wheel assembly is parallel to the base J and tighten with a wrench Hardware used 2 x medium bolts STEP 2 Attach the post sup...

Page 6: ...d through 1 large flat washer and into the hole on top of the head assembly C Tighten stud securely Repeat with the other 2 reflector studs Hardware used 4 x small bolts with lock washers STEP 7 Attac...

Page 7: ...ly C and slide 3 large flat washers over the reflector studs Place the reflector assembly onto the reflector studs and onto the reflector assembly Secure with 3 wing nuts Once you have tightened the w...

Page 8: ...3oz of test solution One part dish soap and three parts water 2 Apply several drops of solution where hose attaches to the regulator 3 Apply several drops of solution where the regulator connects to t...

Page 9: ...valve 3 Push in and turn the control knob to the HI location 4 Keep the control knob depressed and push the RED igniter button simultaneously Push several times to ignite the main burner Repeat until...

Page 10: ...tating to OFF 1 Turn the control knob to the OFF position 2 Wait at least 5 minutes to allow gas to dissipate before re lighting 3 Repeat the lighting steps listed above OPERATION CHECKLIST I am famil...

Page 11: ...r is stored upright in a secure location MAINTENANCE 1 Use soapy water for cleaning Never use flammable or corrosive cleaning agents 2 While cleaning your unit be sure to keep the area around the burn...

Page 12: ...he heater upright in an area sheltered from direct sun and inclement weather You can also cover the heater to protect the heater from build up in air passages Never leave an LPG tank exposed to direct...

Page 13: ...INSTALLATION 4...

Page 14: ...MAINTENANCE TROUBLESHOOTING 5 OPERATION AND MAINTENANCE...

Page 15: ...UFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIA...

Reviews: