6.2 CONNECTION / COMMISSIONING
• Following the mechanical installation of the AQUALUC C:URVE mini it may now be connected and put into ope-
ration.
• Only a qualified electrician, who is familiar with the applicable standards and guidelines, is permitted to per-
form the electrical connection. Ensure that none of the devices are energized during the initial operation!
• To operate the AQUALUC C:URVE mini, a power supply unit suitable for the specifications of the light line is requi-
red. If applicable, a control unit (for dimming of single colours or colour change/dimming of RGB/RGBW), may be
required. We recommend, for example, the controller CHROMOFLEX Casambi.
• The AQUALUC C:URVE mini is designed for 24 V DC operation. Non-observance or operation with a different
voltage can damage the light line. In this case we do not assume any liability.
• Connect both output terminals of the power supply with the input terminal of the controller (if you do not use
the white tone dimming function, connect the output terminals directly to the connection cable of the light line).
• Now connect the cable of the AQUALUC C:URVE mini to the terminals on the marked output side of the controller
(see also the controller manual).
Wire allocation single colour: white: +24 V DC / grey: 0 V
• The product is ready for operation once the power supply unit has been connected to 230 V AC.
• If you connect more than one AQUALUC C:URVE mini to a power supply/controller, make sure that the power
supply unit and the controller can provide sufficient power.
• Please pay attention to the polarity! With an incorrect polarity, there will be no light emission and the light line
may be damaged!
• Operate the product only if it functions properly. In case of malfunction, switch the product off immediately and
operate it again only after a qualified electrician has verified the functionality.
A malfunction can be deemed when:
» damage to the product is visible
» the product does not function properly or it flickers
» overheating is visible or the light line smells burnt
• Avoid mechanical pressure on the LED light lines!
• Only a parallel connection provides a safe operating state. We explicitly advise against a series connection of the
LED modules. Asymmetric voltage drops may cause a severe overloading and destruction of single modules.
• Please pay attention to the dimensioning of the power supply! Dimming is only possible with the PWM method.
• Do not install the light line on or next to hot items/surfaces.
7. CLEANING
Clean the LED light line with a soft, slightly damp cloth. To remove more severe stains use a standard cleansing
material
without
abrasive elements