16
Rev. 3.1 (08.2020)
If lower flow rates are required, it is advisable to use a restrictor for throttling and to operate the pump at the
recommended parameters.
As a general experimental approach, we recommend a high amplitude at varying frequencies. The performance
depends on the environmental conditions.
Combination of micropumps
The micropumps can be combined to achieve higher flow rates or pressure than the single unit can generate.
With
series connection,
the pressures add up.
With
parallel connection,
the volume flows add up.
All values are approximate and no guarantee of specific technical properties.
Changes in the course of technical progress are possible without notice.