5
Rev. 3.1 (08.2020)
Technical specifications
Technical Data of the mp6-hyb
1
mp6-hyb
Order code: mp6-hyb
Pump type
piezoelectric diaphragm pump
Number of actuators
2
Dimensions without connectors
30 x 15 x 3,8 mm
1.1811 x 0.5906 x 0.1498 in.
Weight
2 g
Fluidic connectors
barbed tube clip,
(outer diameter 1.9 mm, length 3.5 mm)
2
Electric connector
flex connector 1.25 mm pitch
Power consumption
~ 50 mW
6
Self-priming
yes
3
Pumping media
Liquids and gases
Operating temperature
0
–
70°C
Life time
5000 h
6
IP code
IP33
7
Material in contact with media
polyphenylsulfone (PPSU)
8
Suitable pump driver
mp-x, mp6-EVA, mp6-OEM, mp6-QuadOEM and mp6-
QuadKEY
Typical values of flow and back pressure for selected media
(values measured with mp-x: 100 Hz, 250 V, SRS):
Liquids
–
water
Controllable flow range
9
𝑄
8 µl/min
–
10000 µl/min
typ. flow rate
𝑄
(p=0)
8 ml/min
4
typ. back pressure p (
𝑄
=0)
500 mbar (7,25 psi)
4
Gases - air
typ.
volume flow
𝑄
(p=0)
20 ml/min
5
typ.
back pressure p (
𝑄
=0)
80 mbar (1,16 psi)
5
1
Typical values. Values can vary under application conditions. Content is subject to changes without notice.
2
Recommended tubing: Tygon tubing 1.3 mm inner diameter.
3
Conditions: Suction pressure > 10 mbar, DI water, settings mp-x: 100 Hz, 250 V, SRS, the volume flow will be reached after a few
minutes of operation time.
4
Conditions: DI water (25°C), room temperature 23°C, settings mp-x: 100 Hz, 250 V, SRS
5
Conditions: air, room temperature 23°C, mp-x: 300 Hz, 250 V, SRS
6
Conditions: settings mp-x: 100 Hz, 250 V, SRS
7
Can be changed to IP44.
8
For media compatibility details please find more information in the corresponding media compatibility sheets.
9
Controllable with frequency, voltage, signal form and more. Please contact us for more information.
Please find more information concerning the controller and the equipment in the corresponding manuals.
30
1
5