Installation
POLARIS SMART HMI
- for Zone 1/21
POLARIS Smart HMI 7” W
EN 20/54
Technical data subject to change.
04/2018
-
Choose the optimum height for operating the POLARIS.
-
Ensure good lighting conditions for a perfectly legible display
(no direct exposure to the sun’s rays).
-
Do not mount in direct proximity to switching or current changing devices.
-
Only install the POLARIS in conjunction with the reinforcement frame in an IP65
enclosure. Failure to comply with this can lead to water penetrating and damaging
the device.
Outdoor Installation
ATTENTION
Damage from condensation or overheating!
Avoid direct sunlight!
Remedy: e.g. shelter with sufficient air circulation.
Remove condensation on the POLARIS immediately.
A POLARIS built into an enclosure must be heated and not removed
from the mains.
Equip the protective housing with breather.
6.2
Mechanical Installation
COUTION
This device is heavy (approx. 4,8 kg).
There is a risk of injury if it is lifted or moved incorrectly.
Only qualified personnel, i.e. trained skilled specialists will have the necessary
specialised know-how to be able to perform all the mechanical work. Familiarity with
and the technically perfect implementation of the safety instructions described in this
manual are preconditions for safe installation and commissioning.