Appendix 

20 

MAK 3003 EASI Ultrasampler Controller Type 6970-31, Configuration, Software version EASI 1.00, SAK 200311 

Appendix 

5.1 

Overview of the Configuration menu 

The following overview should help you to locate individual parameters within 
the Configuration menus. 
 
The software configuration is protected by a password. 
 
 
 

Language

 

 

german 

english

 

french 

Display 

 

Contrast 

 

 

 

dark 

 

 

middle 

 

 

light 

 

Standby time 

 

Time/Date 

 

 

Time 

 

 

Date 

 

Demomode 

 

 

Demomode off 

 

 

Demomode on 

Outputs 

 

Output 1 

 

Output 2 

Inputs 

 

Input 1 

 

Resting state 

 

 

high: negative switching 

 

 

low: positive switching 

 

Input 2 

 

Resting state 

 

 

high: negative switching 

 

 

low: positive switching 

Basic Settings 

 

Filling control mode 

 

 

Flow level meter 

 

 

Milk sensor 

 

Flow FLM at 4-20 mA 

 

Pump capacity 

 

 

small amount 

 

 

middle amount 

 

 

high amount 

 

 

post sucking 

 

 

Sucking time 

 

 

Switching Threshold 

 

 

 

small/medium quantity 

 

 

 

medium/high quantity 

 

Exp. Tour Vol 

 

Motor CIP-Frequency 

 

Correction Factors 

Summary of Contents for MAK 3003

Page 1: ...4239 Gotteszell Deutschland Phone 49 0 9929 301 0 Telefax 49 0 9929 301 112 E Mail gotteszell bartec benke de Internet www bartec benke de MAK 3003 EASI Ultrasampler Controller Type 6970 31 Configurat...

Page 2: ......

Page 3: ...00 SAK 200311 All rights reserved Subject to change without prior notice No part of this document may be reproduced processed or distributed in any form or by any means without the prior written perm...

Page 4: ......

Page 5: ...______________________ 9 4 Menu____________________________________________ 10 4 1 System Info _______________________________________ 10 4 2 Diagnostic ________________________________________ 11 4 3...

Page 6: ...BENKE accepts no liability for any damage resulting from non ob servance of the safety regulations or from non compliance with the operating instructions or operating conditions Secondary damage is ex...

Page 7: ...er slightly from the actual design of the device BARTEC GmbH reserves the right to make technical changes at any time BARTEC GmbH is under no circumstances responsible or liable for any indi rect or c...

Page 8: ...ians Make sure that the information and operating conditions listed by the man ufacturer are followed Follow the instructions on operating and servicing the devices If you notice any damage or deterio...

Page 9: ...cessed measurement values of the flow level meter Switching on the system and operating the vehicle system depend on the spe cific vehicle type and the operating instructions applicable thereto 3 1 Ul...

Page 10: ...menus and also to enter numerical values To accept the numerical values entered and to exit the input dialog use the two buttons on the right side of the display By pressing the green button a menu ca...

Page 11: ...ning the EASI Wheel left and right The selected submenu is marked by a colored bar You can then open the selected menu by pressing the EASI Wheel or pressing the green button If the menu contains subm...

Page 12: ...d list that you want to accept The selected parameter is marked by a bright bar 2 The currently selected parameter is accepted by pressing the EASI Wheel or pressing the green button Numerical entries...

Page 13: ...Changing the configuration is protected by entering a password After confirming the selected field enter password the request for the pass word appear As with numerical entries 3 2 1 2 the password is...

Page 14: ...contains submenus for configuring the system and calling up various functions 4 1 System Info This menu shows the A Nr the version and the selected hardware type System Info Display Typ type name e g...

Page 15: ...voltage and power inputs for FLM are displayed Diagnostics Run Motor 1 The sampling motor 1 will start for a few seconds Run Motor 2 The sampling motor 2 will start for a few seconds Inputs Outputs By...

Page 16: ...s customised to the respective operating conditions and the installed hardware by entering various parameters Changing the configuration is protected by entering a password 3 2 2 In the following para...

Page 17: ...Display Display Contrast In this menu the contrast of the display can be changed dark middle light Standby time Input the Standby time Input in sec Time Date Enter the date and the current time The s...

Page 18: ...tected against the ve hicle power supply voltage to ensure to all control tasks Therefore connec tions to other potentials e g chassis ground reference or reverse voltages in the plus branch are alway...

Page 19: ...ilk is relayed to the ULTRASAMPLER small medium quantity With preset quantities below this value the small pumping rate is relayed to the ULTRASAMPLER with other quantities the me dium rate is relayed...

Page 20: ...value if sampling vial filling volume deviates from the set value Pre Flushing From Estimate In case of intake quantities set quantities lower than the value en tered here no pre flushing occurs L Flu...

Page 21: ...he time period for temperature monitoring Valid until Time until when the milk is monitored for compliance with the maxi mum allowed temperature Min allowed temp Lower temperature limit for milk intak...

Page 22: ...311 No Pumping is not interrupted if the maximum allowed temper ature is exceeded Only a warning message is shown 4 3 9 Cleaning Cleaning Cleaning Id The cleaning Id will be recorded Min Hot Wash Temp...

Page 23: ...All current errors are displayed here Error history All current errors since the last restart are displayed here Status All current statuses are displayed here Status history All current statuses sin...

Page 24: ...Display Contrast dark middle light Standby time Time Date Time Date Demomode Demomode off Demomode on Outputs Output 1 Output 2 Inputs Input 1 Resting state high negative switching low positive switch...

Page 25: ...ng Steps Minimum Pulse Steps Minimum Pulse Frequency Motor 2 Operation Mode Not installed Single sample Tour sample Vial Volume Overfill Tolerance Start Delay Calibration Factor Pre Flushing From Esti...

Page 26: ...MAK 3003 EASI Ultrasampler Controller Type 6970 31 Configuration Software version EASI 1 00 SAK 200311...

Reviews: