APEX Pressurised Cabinet
Ex p Slot Printer
Commissioning
Rev. 0
01-37A2-7D0002_Manual_Exp-Slot-Printer_20220221_0_en.docx
Page 45 of 60
Reservation: We reserve the right to make any technical changes, if we consider them as required. Any changes, errors and misprints do not constitute any grounds for damage claims.
7
Commissioning
A label offset of approx. 8.3 mm must be set in the printer driver
General
We recommend the following procedure for commissioning the Ex p slot printer:
Unpacking and checking the Ex p slot printer entirely for proper function.
Unpack the printer immediately after receipt, and check it for any
potential transport damages.
Keep all packaging material.
Inspect all external surfaces for any damage.
Open the Ex p slot printer and check the interior whether there any
damaged components.
Providing that you become aware of any transport damages during
your inspection, you shall be obligated to take the following actions:
Please notify the logistics company immediately and file a damage
report.
Keep all packaging material to be inspected by the logistics company.
Please notify your authorised BARTEC dealer and inform him
accordingly.
BARTEC shall not be responsible for any damage which may result
from the shipment of the device. Any repairs of such damages
shall not be covered by the warranty.
Provide power supply to the Ex p slot printer.
Establish a direct connection via USB between the set-up PC and the Ex p
slot printer.
Activate the bypass key switch.
Carry out all necessary settings, such as IP address, gateway, etc.
Disconnect the USB connection and replace it with an Ethernet
connection via the Ex p control unit.
Check the print function via the network.
Deactivate the bypass key switch.
Set up the Ex p slot printer at the intended location.
Provide power supply to the Ex p slot printer.
Provide connection to the Ethernet network.