IU 18-441_SFL_r0

 

 

 

 

 

 

 

 

 

4.8 

Особые

 

условия

  

 

  4.8 

Special conditions 

 

 

 

 

Используемое

 

устройство

 

ввода

 

кабеля

 

или

 

отсек

 

для

 

коммутации

 

должны

 

обеспечивать

 

степень

 

защиты

 IP66.  

 

 

 The cable entry device or the compartment used for termination must maintain the 

IP66 rating.

 

 

 
 

 

5. 

ОБСЛУЖИВАНИЕ

 

И

 

ЧИСТКА

 

 

5. 

MAINTAINING AND CLEANING 

 

 

5.1 

Предупреждение

 

о

 

мерах

 

безопасности

 

 

5.1 Safety 

precautions 

 

 

 

Проверки

 

и

 

соблюдение

 

хранения

 

должно

 

выполняться

 

опытным

 

персоналом

который

 

прошел

 

подготовку

ознакомлен

 

с

 

необходимыми

 

инструкциями

 

по

 

деинсталляции

нормативными

 

актами

 

и

 

действующим

 

законодательством

и

 

общими

 

принципами

 

классификации

 

взрывоопасных

 

зон

.   

 

При

 

использовании

 

в

 

потенциально

 

взрывоопасных

 

средах

вызванных

 

пылью

пользователь

 

должен

 

регулярно

 

проводить

 

очистку

 

коробки

 

удаляя

 

пылевые

 

отложения

Максимально

 

допустимое

 

количество

 

пыли

 - 

менее

 5 

мм

 

  The inspections and maintenance on the floodlight must be carried out only from 

expert staff, whose training has included all the necessary instructions on the 
installation modalities, on the laws and standards relevant and on the general 
principles of the classification of the hazardous areas. 
 

  For use in environments where combustible dusts may be present, the user must 

carry on regular cleaning of the apparatus to prevent build-up of dust to surface 
(thickness < 5mm). 

 

 

 

Перед

 

проведением

 

технического

 

обслуживание

 

отключите

 

питание

 

 

Before carrying out whichever maintenance operation, disconnect the electrical 
system. 
 

 

 

6. 

ВЫВОД

 

ИЗДЕЛИЯ

 

ИЗ

 

ЭКСПЛУАТАЦИИ

 

 

6. 

TAKING PRODUCT OUT OF OPERATION 

 

 

6.1 

Утилизация

  

 

6.1 Scraping 

 

Рекомендуется

 

обращаться

 

в

 

специализированные

 

компании

с

 

правом

 

на

 

утилизацию

 

согласно

 

всем

 

законодательным

 

нормам

 

It is recommended to address to specialized companies authorized for the scraping, 
according to laws and standards in force. 

 

Summary of Contents for SFLJ Series

Page 1: ...pyright in any format whole or partial must be before authorized by BARTEC FEAM IU 18 441_SFL_r0 S SF FL LJ J S SF FL LP P S SF FL LA A L LE ED D f fl lo oo od dl li ig gh ht t t ty yp pe es s S SF FL...

Page 2: ...sidual risk 5 2 5 2 IDENTIFICATION 5 2 1 5 2 1 Product brand and type designation 5 2 2 7 2 2 Producer name and address 7 7 Representative importer manufacturer 7 3 7 3 SPECIFICATION OF THE PRODUCT 7...

Page 3: ...by BARTEC FEAM IU 18 441_SFL_r0 4 4 Unpacking 12 4 5 13 4 5 Safety disposing of packaging material 13 4 6 14 4 6 Mounting instruction 14 4 7 15 4 7 Notes 15 4 8 16 4 8 Special conditions 16 5 16 5 MA...

Page 4: ...s site installer equipment s users assigned to the maintenance This handbook must be conserved must be conserved with the maximum care and it be available always for eventual consultations therefore i...

Page 5: ...ed by the missed observance of the contained norms in the manual present The guarantee is made factory they don t result therefore covered the costs for the transport of the equipment in guarantee fro...

Page 6: ...SM AL 1 30 XX 1 38 1 44 1 46 1 2 3 4 LED P 04 SM AL 08 AS XX 12 ST 16 1 2 3 4 LED A 16 SM AL 20 AS XX 24 28 32 36 40 SM AS c ST c AL XX Into tables below possible combinations 1 2 3 4 Model n LED Opti...

Page 7: ...floodlight type SFL are intended for use on the surface in areas in which during the normal activities explosive atmospheres caused by gases vapours mists and or air dust mixtures have scarce possibi...

Page 8: ...sent document is property of BARTEC FEAM Its copyright in any format whole or partial must be before authorized by BARTEC FEAM IU 18 441_SFL_r0 A B C 3 2 3 2 Dimensions and weight floodlight for trans...

Page 9: ...5 631 525 122 28 21 631 525 122 32 21 631 525 122 36 22 631 525 122 40 22 631 525 122 3 3 3 3 Technical data Materials EN AB 46100 UNI EN 1706 1999 AISI303 304 316 316L UNI EN10088 3 2005 60 C 200 C 4...

Page 10: ...the labels Main tag example 1 2 3 4 5 6 7 9 8 1 2 3 4 5 6 7 TC RU 8 TC RU 1 brand name and address of the manufacturer 2 equipment type designation given by manufacturer 3 year of construction and ser...

Page 11: ...FLJ Surface exposed to the wind SFLP Surface exposed to the wind SFLA Product in class I require grounding Presence of dangerous electrical voltage Class II product grounding not required Replace any...

Page 12: ...f particular demands to assigned staff therefore it is recommended to carry out such operation observing the common rules of accident prevention 4 3 4 3 Safety precautions before use In the event of i...

Page 13: ...zed by BARTEC FEAM IU 18 441_SFL_r0 To make sure that pack have not suffered external damages during the transport Place down the right side of the pack and unpacked the electrical pump extract the eq...

Page 14: ...of the following instruction so we recommend keeping them Make sure you have removed tension before installation or maintenance Follow the installation procedures to ensure the unit proper functioning...

Page 15: ...socket respecting polarities 3 S 3 Pic 3 Pic 3 Swan neck suggested cable positioning to avoid accumulation of condensation on the cable gland Fix the floodlight by adequate stainless steel screws usi...

Page 16: ...the floodlight must be carried out only from expert staff whose training has included all the necessary instructions on the installation modalities on the laws and standards relevant and on the gener...

Reviews: