RDG603A11 - Issue 10 - Shire 14 85, 130 WB Owners
Manual Page 25 of 52
19.
S
eawater Strainer
A bulkhead mounted seawater strainer or similar is not supplied with the engine, we
recommend that one is fitted between the seawater inlet (seacock) and the sea water
pump inlet. The size of the Inlet and connections are:
•
Shire 14 85WB
–
32mm (crank driven pump)
•
Shire 14 85WB
–
45mm (belt driven pump)
•
Shire 14 130WB
–
45mm (belt driven pump)
20. Exhaust System (Dry Exhaust)
WARNING:
EXHAUST HAZARD!
NEVER OPERATE ENGINE WITHOUT PROPER
VENTILATION. NEVER BLOCK VENTS OR OTHER MEANS OF VENTILATION. ALL
COMBUSTION ENGINES CREATE CARBON MONOXIDE GAS DURING
OPERATION. ACCUMULATION OF THIS GAS COULD CAUSE ILLNESS OR EVEN
DEATH.
The exhaust outlet size on the engine is 1
1
/
2
" BSP female. There must be a flexible
exhaust hose of suitable exhaust grade between the engine and the silencer or hull
outlet. The outlet must be above the waterline at all times.
•
Make sure exhaust increases then decreases in height as shown above
✓