background image

INSTALLATION INSTRUCTIONS

10070166 Rev 4 - 04/19

3

 

SELF-TEST/SELF-DIAGNOSTIC

OPERATING INSTRUCTIONS

KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

Installation

I M P O R T A N T:

 ONCE ALL EMERGENCY LAMPS HAVE BEEN CONNECTED TO THE UNIT EQUIPMENT, APPLY 

NORMAL AC POWER AND CHARGE FOR 24 HOURS. 

Operation

The purpose of this option is to provide self-testing and self-diagnostic capabilities to the unit equipment. At 

predetermined intervals, the unit equipment will automatically switch into battery mode. The unit equipment will also 

perform various self-diagnostic tests of the unit. Visual signaling will alert maintenance personnel to a fault of the unit 

equipment electronics, emergency lamp(s), battery and/or battery charger. The circuitry continuously monitors the 

operating condition of the unit equipment and battery charging circuit/battery supply voltage. Refer to table 1 for units 

equipped with a tri-color LED indicator. Refer to table 2 for units equipped with a numeric indicator.

Self Test Features

• The unit equipment will automatically switch to battery mode every 28 days for a period of 1 minutes.
• The unit equipment will automatically switch to battery mode every 6 months for a period of 90 minutes.

Manual Test Features

• Press the TEST BUTTON momentarily for a 2 second test. (Tri-Color LED unit only)
• Press the TEST BUTTON until the LED turns ORANGE or Numeric display shows “7” for a manual 1 minute test.
• Press the TEST BUTTON until the LED flashes RED/GREEN, (Tri-Color LED unit only) for manual 90 minute test.

LED Indication

Steady
Pulse
Steady
Pulse

Steady

Pulse
LED Color

LED Color

Green
Green
Red
Red

Orange

Orange
Red/Green

Unit Condition

Float Charge
Hi-Rate Charge
Low Batt Voltage
Emer Lamp Failure

No AC Power

Charge Failure

1 Minute Test
Batt Disconnected
90 Minute Test

Comment

Batt Fully Charged
Batt Under High-Rate Charge
Replace Battery

Check AC Connection

Replace Transformer

1 Min Test Every 28 Days
Check Batt Connections
90 Min Test Every 6 Months

Replace Damaged or 

Missing Lamps

Table 1 - Tri-color LED Indicator 

CHARGED      

 

0     Float charging

CHARGING     1     Hi rate charging
EM/BATT         2     Discharging
CHRG FAIL     

 

3     Charger failure

DISC BATT    

    

4     Battery not connected 

LAMP FAIL      5     Lamp failure 
LOW BATT      6     Low battery voltage
1 MIN TEST     7     Manual testing
90 MIN TEST   8     Self testing

STATUS LEDGE    Condition

Table 2 - Numeric Indicator 

Numeric Display 

Tri-Color LED

CRL SERIES

800.533.3948 • www.barronltg.com 

Reviews: