Fig. 32. Blade arbor bolts
BLADE ARBOR ASSEMBLY AND PULLEYS
Periodically, check the tightness of the four blade arbor housing mounting bolts (Fig. 32) to make sure they are
securely tightened to the oil reservoir. Should the 2" OD die cast pulleys on either the motor or blade arbor
shaft need to be removed or replaced, loosen the set screw on the hub of each pulley with a US standard
Allen/hex wrench to remove the pulley from the shaft.
MAIN MOTOR
The BD10 is equipped with a Baldor or Leeson 1/3 HP 1725 RPM single-phase 120 volt 60 Hz 8 amp motor.
The motor shaft has sealed ball bearings and requires no lubrication. The motor is protected from thermal
damage (overheating) with an automatic shut-off switch. If the motor overheats, it will automatically shut off
and restart once its internal components cool down. The Leeson motors now being used have no reset button.
Be sure to shut off the main motor by placing the switch lever to the OFF position and disconnecting the power
source. After allowing the motor to cool (2 to 3 hours), restart the unit by turning the switch to ON. If the motor
does not restart after a cool down period, remove the motor and have an authorized repair service center for
Baldor or Leeson inspect the motor. Barranca Diamond can refer you to an authorized motor repair service
center in your area.
BD10
MAINTENANCE
Export version of BD10 Saw with a 220 volt/50Hz motor available (part # 169201).