Figure 2 shows a typical installation of an “A” version fl oat, 
(an “AU” version will attach to the pump), using a piggy-back 
plug.

General Comments: 

1) Never work in the sump with the power on.

2) Level controls are factory set for a pumping differential of 9 
inches. If that is the cycle desired, simply circle the discharge 
pipe with the pipe mounting strap, feed the end through the 
worm drive, and tighten with a screwdriver. Be certain that the 
level control cannot hang up or foul in it’s swing. Also, make 
certain the top of the pump is still submerged when the level 
control is in the ‘off’ mode.

3) If a higher pump differential is needed, grip the cord near 
the neck of the fl oat, then using the other hand, exert a 
steady force on the lower edge of the cable clamp. The cable 
clamp should slide up to the new pivot point. Attach the level 
control to the discharge hose in the manner described above.

4) Plug the level control plug into the receptacle, then plug 
the pump into the piggyback plug. One cycle of operation 
should be observed, so that any potential problems can be 
corrected.

5) It is recommended that the fl oat should be set to insure 
that the sump well liquid level never drops below the top of 
the motor housing.

6.) Figure 3 shows a typical connection for pumps with 
the wide angle fl oat and piggy-back plug. For manual and 
automatic operations.

Automatic - 

 

Plug fl oat cord into outlet, then plug pump

 

      

cord into fl oat cord.

Manual - 

 

Plug pump cord directly int outlet.

C-4) Electrical Connections:
C-4.1) Power and Control Cable:

The cord assembly mounted to the pump must not be 

modifi ed 

in  any  way  except  for  shortening  to  a  specifi c  application. 
Any splice between the pump and the control panel must be 
made  in  accordance  with  all  applicable  electric  codes.  It  is 
recommended that a junction box, if used, be mounted outside 
the sump or be of at least Nema 4 (EEMAC-4) construction if 
located within the wet well. 

Do not use the power or control 

cable to lift pump. NOTE: The white wire is NOT a neutral 
or ground lead, but a power carrying conductor.

C-4.2) Overload Protection :
C-4.2-1)  Three Phase (Optional) - 

The normally closed 

(N/C) thermal sensor is embedded in the motor windings and 
will detect excessive heat in the event an overload condition 
occurs. The thermal sensor will trip when the windings become 
too hot and will automatically reset itself when the pump motor 
cools to a safe temperature. It is recommended that the thermal 
sensor be connected in series to an alarm device to alert the 
operator of an overload condition, and/or the motor starter coil 
to stop the pump. In the event of an overload, the source of this 
condition should be determined and rectifi ed immediately. 

DO 

NOT  LET  THE  PUMP  CYCLE  OR  RUN  IF AN  OVERLOAD 
CONDITION OCCURS !

120 Volt 1 Phase

Automatic

240 Volt 1 Phase

FIGURE 3

Manual

Manual

Automatic

TYPICAL INSTALLATION WITH WIDE ANGLE 

LEVEL CONTROL

FIGURE 2

Summary of Contents for SE51A

Page 1: ...program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario C...

Page 2: ...18 22 SE HT SINGLE SEAL EXPLODED VIEW Fig 19 23 3SE DS DOUBLE SEAL CROSS SECTION Fig 20 24 3SE DS DOUBLE SEAL EXPLODED VIEW Fig 21 25 PARTS LIST 26 28 RETURNED GOODS POLICY 32 WARRANTY 31 WARRANTY RE...

Page 3: ...rt fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety dev...

Page 4: ...Filled Reservoir Material Carbon Ceramic Buna N Hardware 300 Series Stainless CORD ENTRY 15 ft 5 m 20 ft 6 1 m Cord Plug on 120 Volt 5HP 240 Volt 1 Phase Quick connect custom molded for sealing and s...

Page 5: ...le Seal SE A SE HTA Single Seal SE AU SE HTAU Single Seal Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models Plugs for 120 Volt and 5Hp 240...

Page 6: ...6 Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models inches mm Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models 3SE L Single Seal 3SE DS Double Seal...

Page 7: ...or basin that is free of hard debris like gravel stones sand or earth The sump lift station or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage efflu...

Page 8: ...rations Automatic Plug float cord into outlet then plug pump cord into float cord Manual Plug pump cord directly int outlet C 4 Electrical Connections C 4 1 Power and Control Cable The cord assembly m...

Page 9: ...tamped on the pump identi cation plate to the available power D 2 Check Pump Rotation Before putting pump into service for the rst time the motor rotation must be checked Improper motor rotation can r...

Page 10: ...5 3 14 4 SOW 0 570 14 5 40 80 52 00 3SE554L 0 5 600 3 60 1750 H B 1 0 3 4 14 4 SOW 0 570 14 5 77 60 89 76 3SE774L 0 75 200 240 1 60 1750 G K F 7 4 7 0 21 5 25 8 14 3 SOW 0 530 13 5 1 86 10 20 2 74 10...

Page 11: ...he pressure does not hold then the leak must be located and repaired Pumps that have NOT had the oil drained from the Motor Housing The pressure test may be done with the oil at its normal level Remov...

Page 12: ...volute 1 Position lockwasher 12 on cap screw 26 and screw into volute 1 Torque to 100 in lbs Check for free rotation of motor and impeller F 3 Shaft Seal Service CAUTION Handle seal parts with extrem...

Page 13: ...ing sure it is seated on retainer and not cocked or resting on bellows tail Slide retaining ring 28d over shaft and let rest on spring 28c Replace snap ring 32 in groove of shaft Set square ring 27 in...

Page 14: ...ce station or Barnes Pumps Service department Inspect motor winding for shorts and check resistance values Check rotor for wear If rotor or the stator windings are defective the complete motor must be...

Page 15: ...eplacement parts ALWAYS furnish the following information 1 Pump serial number and date code Paragraph G 4 2 Pump model number Paragraph G 3 3 Pump part number Paragraph G 2 4 Part description 5 Item...

Page 16: ...16 FIGURE 13...

Page 17: ...17 FIGURE 13...

Page 18: ...18 FIGURE 13 CONTIUED...

Page 19: ...cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so t...

Page 20: ...20 FIGURE 16 SE L 3SE L Series Single Seal...

Page 21: ...21 FIGURE 17 SE L 3SE L Series Single Seal...

Page 22: ...22 FIGURE 18 SE HT High Temp Series Single Seal...

Page 23: ...23 FIGURE 19 SE HT High Temp Series Single Seal...

Page 24: ...24 FIGURE 20 3SE DS Series Double Seal...

Page 25: ...25 FIGURE 21 3SE DS Series Double Seal...

Page 26: ...BS 070963 SE774L 3SE774L SE1074L 3SE1074L 029792BD 070963 3SE774DS 3SE1074DS 071354BS None SE794L SE744L 3SE794L 3SE744L SE1094L None SE1044L 3SE1094L 3SE1044L 071354BD None 3SE794DS 3SE744DS 3SE1094D...

Page 27: ...a 084346TH 5 00 Dia 084346TJ 4 88 Dia 084346TK 4 75 Dia 084346TL 4 63 Dia 084346TM 4 50 Dia 084346TN 4 38 Dia 084346TP 4 25 Dia 084346TQ 4 13 Dia 084346TR 4 00 Dia 36 1 027344 t Gasket 39 1 014270 Pip...

Page 28: ...ABLE LENGTH ITEM 16 120 VOLT 1 PHASE STD Temp ITEM 16 120 VOLT 1 PHASE High Temp ITEM 16 240 VOLT 1 PHASE 0 5HP STD HT ITEM 16 240 VOLT 1 PHASE 0 75 1HP STD HT ITEM 16 3 PHASE ITEM 55 OPTIONAL STD Tem...

Page 29: ...29 Notes...

Page 30: ...30 Notes...

Page 31: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Page 32: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Reviews: