PARTS KITS

Seal Repair Kits: 
 

Single Seal .......... ..P/N - 130180  

(

+) 2, 20, 27, 28, 36

 

Double Seal ...........P/N - 130176  

(

†) 2, 20, 27, 28, 32, 36

Service Kits:
 

Single Seal .............P/N - 130207  

(

◊)

 

2, 19, 20, 22, 24, 25, 27, 28, 36, 49, 65, 66

 

Double Seal ...........P/N - 130172  

(

t

)

 

2, 19, 20, 22, 24, 25, 27, 28, 32, 36, 44, 49, 65, 66

Seal Tool Kit  ....................P/N - 107271
Pressure Gauge Kit  ........P/N - 085343 

PARTS LIST

ITEM 

QTY. 

PART NO. 

 

DESCRIPTION

055400 

 

Volute 

(Std)

 

071114 

 

Volute 

(For use with Optional Strainer)

069140 

+†◊

t

  Gasket

026210 

 

Flange 

2” Discharge

 

 

105153 

 

 

3” Discharge

003217 

 

Pipe Plug 

All double seal (Std), .25” NPT, ZP

 

039383 

 

Moisture Sensor Probes (Optional) moisture sensor

084532 

 

Seal Plate 

All single seal

 

 

084906 

 

 

All double seal

105196 

 

Motor Housing 

(Std)

 

 

105196HA 

 

 

(Optional) for all AU and HTAU, moisture and temp. sensors

Motor:

 

 

Capacitor (item 9):

 

 

030369BS 

 

034964 

SE51, SE51A, SE51AU, 3SE514L

 

 

030369BD 

 

070963 

3SE514DS

 

 

030370BS 

 

070963 

SE52, SE52AU, 3SE524L

 

 

030370BD 

 

070963 

3SE524DS

 

 

085472BS 

 

None 

SE51HT, SE51HTA, SE51HTAU, SE52HT, SE52HTAU

 

 

071352BS 

 

None 

SE594L, 3SE594L, SE544L, 3SE544L

 

 

071352BD 

 

None 

3SE594DS, 3SE544DS

 

 

092854BS 

 

None 

SE554L, 3SE554L

 

 

092854BD 

 

None 

3SE554DS

 

 

029792BS 

 

070963 

SE774L, 3SE774L, SE1074L, 3SE1074L

 

 

029792BD 

 

070963 

3SE774DS, 3SE1074DS

 

 

071354BS 

 

None 

SE794L, SE744L, 3SE794L, 3SE744L, SE1094L, 

 

 

 

 

None 

SE1044L, 3SE1094L, 3SE1044L

 

 

071354BD 

 

None 

3SE794DS, 3SE744DS, 3SE1094DS, 3SE1044DS

 

 

092855BS 

 

None 

SE754L, 3SE754L, SE1054L, 3SE1054L

 

 

092855BD 

 

None 

3SE754DS, 3SE1054DS

96 oz 

029034 

 

Oil 

All single seal

 

120oz 

029034 

 

Oil 

All double seal (Includes 24 oz. in Seal Chamber)

034964 

Capacitor (30MFD)  1 Phase

 

070963 

 

Capacitor (20 MFD)  1 Phase

10 

039858 

 

Capacitor Bracket 

1 Phase

11 

1-156-1 

 

Hex. Hd. Cap Screw (Std), 5/16-18 x 1.00” Lg., Stainless

 

1-156-1 

 

Hex. Hd. Cap Screw (Optional) for all AU and HTAU, moisture and temp. sensors

12 

10 

026322 

 

Lockwasher 

(Std), 5/16, Stainless

 

12 

026322 

 

Lockwasher 

(Optional) for all AU and HTAU, moisture and temp. sensors

13 

103503 

 

Handle

16 

See Table 2 

 

Power Cable Set

16a 

103582 

 

Compression Flange, Included with Cable Set

19 

105197 

◊ 

Snap Ring 

(Std)

 

105197 

t

 

Snap Ring 

(Optional) for all AU and HTAU, moisture and temp. sensors

20 

2-31051-224 

+◊ 

O-ring 

(Std)

 

2-31051-224 

t

 

O-ring 

(Optional) for all AU and HTAU, moisture and temp. sensors

21 

103584 

 

Terminal Block 

 

1 Phase

 

 

103583 

 

 

 

3 Phase

22 

105111 

t

 

Ground Wire Assembly 

(Std)

* Units with build code date (see section G-4) before -0901 may 
use capacitor part number, 070963 or the 034964 part number.

Summary of Contents for SE51A

Page 1: ...program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario C...

Page 2: ...18 22 SE HT SINGLE SEAL EXPLODED VIEW Fig 19 23 3SE DS DOUBLE SEAL CROSS SECTION Fig 20 24 3SE DS DOUBLE SEAL EXPLODED VIEW Fig 21 25 PARTS LIST 26 28 RETURNED GOODS POLICY 32 WARRANTY 31 WARRANTY RE...

Page 3: ...rt fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety dev...

Page 4: ...Filled Reservoir Material Carbon Ceramic Buna N Hardware 300 Series Stainless CORD ENTRY 15 ft 5 m 20 ft 6 1 m Cord Plug on 120 Volt 5HP 240 Volt 1 Phase Quick connect custom molded for sealing and s...

Page 5: ...le Seal SE A SE HTA Single Seal SE AU SE HTAU Single Seal Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models Plugs for 120 Volt and 5Hp 240...

Page 6: ...6 Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models inches mm Plugs for 120 Volt and 5Hp 240 Volt Single Phase Models 3SE L Single Seal 3SE DS Double Seal...

Page 7: ...or basin that is free of hard debris like gravel stones sand or earth The sump lift station or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage efflu...

Page 8: ...rations Automatic Plug float cord into outlet then plug pump cord into float cord Manual Plug pump cord directly int outlet C 4 Electrical Connections C 4 1 Power and Control Cable The cord assembly m...

Page 9: ...tamped on the pump identi cation plate to the available power D 2 Check Pump Rotation Before putting pump into service for the rst time the motor rotation must be checked Improper motor rotation can r...

Page 10: ...5 3 14 4 SOW 0 570 14 5 40 80 52 00 3SE554L 0 5 600 3 60 1750 H B 1 0 3 4 14 4 SOW 0 570 14 5 77 60 89 76 3SE774L 0 75 200 240 1 60 1750 G K F 7 4 7 0 21 5 25 8 14 3 SOW 0 530 13 5 1 86 10 20 2 74 10...

Page 11: ...he pressure does not hold then the leak must be located and repaired Pumps that have NOT had the oil drained from the Motor Housing The pressure test may be done with the oil at its normal level Remov...

Page 12: ...volute 1 Position lockwasher 12 on cap screw 26 and screw into volute 1 Torque to 100 in lbs Check for free rotation of motor and impeller F 3 Shaft Seal Service CAUTION Handle seal parts with extrem...

Page 13: ...ing sure it is seated on retainer and not cocked or resting on bellows tail Slide retaining ring 28d over shaft and let rest on spring 28c Replace snap ring 32 in groove of shaft Set square ring 27 in...

Page 14: ...ce station or Barnes Pumps Service department Inspect motor winding for shorts and check resistance values Check rotor for wear If rotor or the stator windings are defective the complete motor must be...

Page 15: ...eplacement parts ALWAYS furnish the following information 1 Pump serial number and date code Paragraph G 4 2 Pump model number Paragraph G 3 3 Pump part number Paragraph G 2 4 Part description 5 Item...

Page 16: ...16 FIGURE 13...

Page 17: ...17 FIGURE 13...

Page 18: ...18 FIGURE 13 CONTIUED...

Page 19: ...cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so t...

Page 20: ...20 FIGURE 16 SE L 3SE L Series Single Seal...

Page 21: ...21 FIGURE 17 SE L 3SE L Series Single Seal...

Page 22: ...22 FIGURE 18 SE HT High Temp Series Single Seal...

Page 23: ...23 FIGURE 19 SE HT High Temp Series Single Seal...

Page 24: ...24 FIGURE 20 3SE DS Series Double Seal...

Page 25: ...25 FIGURE 21 3SE DS Series Double Seal...

Page 26: ...BS 070963 SE774L 3SE774L SE1074L 3SE1074L 029792BD 070963 3SE774DS 3SE1074DS 071354BS None SE794L SE744L 3SE794L 3SE744L SE1094L None SE1044L 3SE1094L 3SE1044L 071354BD None 3SE794DS 3SE744DS 3SE1094D...

Page 27: ...a 084346TH 5 00 Dia 084346TJ 4 88 Dia 084346TK 4 75 Dia 084346TL 4 63 Dia 084346TM 4 50 Dia 084346TN 4 38 Dia 084346TP 4 25 Dia 084346TQ 4 13 Dia 084346TR 4 00 Dia 36 1 027344 t Gasket 39 1 014270 Pip...

Page 28: ...ABLE LENGTH ITEM 16 120 VOLT 1 PHASE STD Temp ITEM 16 120 VOLT 1 PHASE High Temp ITEM 16 240 VOLT 1 PHASE 0 5HP STD HT ITEM 16 240 VOLT 1 PHASE 0 75 1HP STD HT ITEM 16 3 PHASE ITEM 55 OPTIONAL STD Tem...

Page 29: ...29 Notes...

Page 30: ...30 Notes...

Page 31: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Page 32: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Reviews: