Barnes QDX25-SS Installation Manual Download Page 4

4

SECTION B: GENERAL INFORMATION

B-1) To the Purchaser:

Congratulations! You are the owner of one of the fi nest 
pumps on the market today. CP&S pumps are products 
engineered and manufactured of high quality compo-
nents. Over one hundred years of pump building experi-
ence along with a continuing quality assurance program 
combine to produce a pump which will stand up to the 
toughest applications.

This manual will provide helpful information concerning 
installation, maintenance, and proper service guidelines.

B-2) Receiving:

Upon receiving the pump, it should be inspected for dam-
age or shortages. If damage has occurred, fi le a claim 
immediately with the company that delivered the pump. If 
the manual is removed from the packaging, do not lose or 
misplace.

B-3) Storage:
Short Term-

 CP&S Pumps are manufactured for effi cient 

performance following short inoperative periods in stor-
age. For best results, pumps can be retained in storage, 
as factory assembled, in a dry atmosphere with constant 
temperatures for up to six (6) months.

Long Term-

 Any length of time exceeding six (6) months, 

but not more than twenty-four (24) months. The unit 
should be stored in a temperature controlled area, a 
roofed over walled enclosure that provides protection 
from the elements (rain, snow, wind-blown dust, etc.), and 
whose temperature can be maintained b40 deg. 
F and +120 deg. F. (4.4 - 49°C).

Pump should be stored in its original shipping container. 
On initial start up, rotate impeller by hand to assure seal 
and impeller rotate freely. If it is required that the pump be 
installed and tested before the long term storage begins, 
such installation will be allowed provided:

1.)  The pump is not installed under water for more than
 

one (1) month.

2.)  Immediately upon satisfactory completion of the test,
 

the pump is removed, thoroughly dried, repacked in

 

the original shipping container, and placed in a 

 

temperature controlled storage area.

B-4) Service Centers:

For the location of the nearest Barnes Center, check your 
Barnes representative or Crane Pumps & Systems, Inc., 
Service Department in Piqua, Ohio, telephone (937) 778-8947 
or Crane Pumps & Systems Canada, in Brampton, Ontario, 
(905) 457-6223.

SECTION C: INSTALLATION

C-1) Location:

These pumps are recommended for general and light 
construction, for sump and dewatering drainage, for dewa-
tering manholes and transformer vaults, for pit, tunnel and 
trench dewatering, and for fl ood, fi re and other emergency 
service cleanup.

Before pumping fl uids other than water, consult the 
factory, giving fl uid, fl uid temperature, specifi c 
gravity, viscosity, capacity in USGPM and total head and/
or pressure requirements, including friction loss through 
discharge line, fi ttings, valves, etc. Pump may run dry 
for 5 to 10 minutes in air without damage where air can 
circulate freely through the pump. 

DO NOT

 allow pump to 

be buried in mud or sand.

C-2) Discharge:

Discharge hose is recommended. If rigid pipe is used, 
install so that there is no weight or strain on the pump.

C-3) Liquid Level Controls: (If Applicable)

Attach “ON” fl oat to discharge hose or pump cable at 
desired pump “ON” level. Attach “OFF” fl oat to discharge 
hose or pump cable at desired pump “OFF” level. The 
“OFF” fl oat must be below the “ON” fl oat. To attach the 
fl oats, thread the cable strap through the buckle with 
the ratchet pawl, cinch up tight, thread excess strapping 
through outer buckle slot. Be certain the level controls 
cannot hang up or foul in its swing. It is recommended that 
the pump is completely submerged when the level control 
is in the “OFF” mode.

C-4.1) Electrical Connections:

The pump comes with a three wire cord and a three prong 
grounded plug on the 120 volt models. The cord assembly 
mounted to the pump must not be modifi ed in any way. 
This pump comes complete with a 3 wire cord and 3 prong 
grounded plug that must be connected into a 3 wire 
grounded Ground Fault receptacle. 

DO NOT

 remove 

ground pin from electrical plug.  

DO NOT USE THE 

POWER CABLE TO LIFT PUMP.

C-4.2) Overload Protection:

An automatic thermal overload protects the motor. The 
type of in-winding overload protector used is referred to 
as an inherent overheating protector and operates on the 
combined effect of temperature and current. This means 
that the overload protector will trip out and shut the pump 
off if the windings become too hot or the current passing 
through them becomes too high. 

It will then automatically reset and restart the pump after 
the motor cools to a safe temperature. In the event of an 
overload, the source of this condition should be deter-
mined and rectifi ed immediately. 

DO NOT LET THE 

PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION 
OCCURS!

E

N
G

L

I

S

H

Summary of Contents for QDX25-SS

Page 1: ...duct changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 118791 Rev D Series QDX25 SS 4NU10 25 HP 120 Volt Series QDX33 SS 4NU11 33 HP 120 Volt E S P A Ñ O ...

Page 2: ...ure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT remove c...

Page 3: ... N Hardware 300 series stainless steel CORD ENTRY 20 Ft 6m Cord with Plug Molded for strain relief and compression seal MOTOR Design Air Filled Insulation Class B SINGLE PHASE Permanent Split Capacitor PSC Includes Overload protection in motor PUMP SPECIFICATIONS inches mm Models QDX25 SS 4NU10 MODEL NO PART NO HP VOLT PH HERTZ RPM FULL LOAD AMPS QDX25 SS 118531 25 120 1 60 3450 2 0 QDX33 SS 11853...

Page 4: ...commended for general and light construction for sump and dewatering drainage for dewa tering manholes and transformer vaults for pit tunnel and trench dewatering and for flood fire and other emergency service cleanup Before pumping fluids other than water consult the factory giving fluid fluid temperature specific gravity viscosity capacity in USGPM and total head and or pressure requirements inc...

Page 5: ... NUT TIGHT CHECK FREQUENTLY There shall be no openings in the casing of the electrical parts The operating voltage shall match the voltage rating of the motor E 2 Cable Requirements Special care shall be taken in handling the cable against mechanical injury and wear Connections and wiring to the power source shall be in accordance with all electrical and safety codes SECTION F WARRANTY REPAIR F 1 ...

Page 6: ... operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate...

Page 7: ... of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND E...

Page 8: ... Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Cran...

Page 9: ... posible que se hagan cambios a los productos Por esta razón Crane Bombas y Sistemas se reserva el derecho de cambiar el producto sin previo aviso por escrito 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Teléfono 937 778 8947 Teléfono 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Formulario No 118791 Rev D Serie QDX25 SS y 4NU10 0 25 HP 120 Vol...

Page 10: ...No opere la bomba sin que las cubiertas y los dispositivos de seguridad estén instalados Ponga siempre en su lugar los dispositivos de seguridad que se hayan retirado durante el mantenimiento o reparaciones Fije la bomba en una posición estable de funcionamiento para que no se caiga hacia un lado al suelo o se deslice No exceda la recomendación del fabricante para obtener un funcionamiento superio...

Page 11: ...oxidable serie 300 ENTRADA DEL CORD Cordón con enchufe de 6m 20 pies Moldeado para reducción de tensión y sello de compresión MOTOR Diseño Lleno de aire aislamiento clase B MONOFASICO Capacitor permanentemente dividido PSC Incuye protección contra sobrecargas en el motor ESPECIFICACIONES DE LA BOMBA mm pulgadas Modelos QDX25 SS 4NU10 Modelo no No de pieza Hp Voltios Ph Hz Velocidad Amperios de car...

Page 12: ...es para drenaje de sumideros y extracción de agua para extracción de agua de salas de transformadores y de pasos de hombre para extracción de agua de pozos túneles y zanjas y para servicios de limpieza por inundaciones incendios u otras emergencias Antes de bombear otros líquidos distintos de agua onsulte con la fábrica y explique el tipo de líquido la temperatura del líquido la gravedad específic...

Page 13: ...nes óptimas MANTENGA APRETADA LA TUERCA ESTANCADORA DEL CABLE VERIFIQUE CON FRECUENCIA La carcasa de las partes eléctricas deberá estar libre de aberturas La tensión de funcionamiento deberá ser igual a la tensión nominal del motor E 2 Requisitos de cable Se debe tener cuidado especial al manejar el cable para evitar el desgaste y las lesiones producidos por acción mecánica Las conexiones y el cab...

Page 14: ...6 E S P A Ñ O L ...

Page 15: ... seguridad y las condiciones Limpie toda obstrucción de la cavidad del rotor y la entrada 9 Afloje la unión ligeramente para dejar que salga el aire atrapado Verifique que el nivel de apagado del interruptor se ha ajustado de forma que la cavidad del rotor siempre esté inundada Limpie el orificio de ventilación 10 Revise la rotación Si el suministro eléctrico es trifásico invierta dos o tres condu...

Page 16: ...se base en las especificaciones del funcionamiento debe existir por escrito y llevar la firma de nuestro representante autorizado Debido a errores en las pruebas fuera de fábrica si surge un conflicto entre los resultados de las pruebas fuera de fábrica realizadas por o para el usuario y las pruebas de laboratorio modificadas para funcionamiento fuera de fábrica éstas últimas tendrán validez sobre...

Page 17: ...para asegurarse que los empleados no se expongan a peligros para su salud al manipular dicho material Todas las leyes y reglamentos pertinentes tendrán validez IMPORTANTE REGISTRO DE LA GARANTIA Su producto está cubierto por la Garantía adjunta Para llenar el Formulario de Registro de la Garantía vaya a http www cranepumps com ProductRegistration Si usted tiene que hacer un reclamo bajo lo provist...

Page 18: ......

Reviews: