Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY

 and to 

PREVENT 

EQUIPMENT PROBLEMS.

 To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury orIndicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION!

 Warns about hazards that 

can or will cause minor

 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING!

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only qualifi 

ed personnel should install, operate and repair 

pump. Any wiring of pumps should be performed by a qualifi ed 
electrician.

WARNING !

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 
accordance with the National Electric Code (NEC) or 
the Canadian Electrical Code (CEC) and all applicable 
state, province, local codes and ordinances. Improper 
grounding voids warranty.

WARNING!

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag. 

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

 

CAUTION !

 Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing.

 

WARNING !

 Do not pump hazardous materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

 

CAUTION !

 

Do not

 block or restrict discharge hose, as 

discharge hose may whip under pressure.

 

WARNING !

 Do not wear loose clothing that may  

become entangled in moving parts.

  

WARNING !

 Keep clear of suction and discharge 

openings. 

DO NOT 

insert fi ngers in pump with power 

connected.  

Always wear eye protection when working on pumps. 

Make sure lifting handles are securely fastened each 

 

time before lifting. 

DO NOT

 operate pump without safety 

devices in place. Always replace safety devices that 

 

have been removed during service or repair. Secure the 
pump in its operating position so it can not tip over, fall  
or slide.

 

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor  
to overheat.

 

DO NOT

 remove cord and strain relief. 

DO NOT

 connect 

conduit to pump.

 

WARNING !

 Cable should be protected at all times to  

avoid punctures, cut, bruises and abrasions. Inspect 
frequently. Never handle connected power cords with 

 

wet hands.

 

WARNING !

 To reduce risk of electrical shock, all  wiring 

and junction connections should be made per  the NEC 
or CEC and applicable state or province and  local 
codes. Requirements may vary depending on  usage 
and location.

 

WARNING!

 Submersible Pumps are not approved for 

 

use in swimming pools, recreational water installations 
decorative fountains or any installation where human 
contact with the pumped fl uid is common.

  

WARNING!

 Products returned must be cleaned, 

sanitized, or decontaminated as necessary prior to 
shipment, to insure that employees will not be exposed 
to health hazards in handling said material. All Applicable 
Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in  potable water 
applications. For non-leaded copper  alloy materials of 
construction, please contact factory.

 

Crane Pumps & Systems, Inc. is not responsible for 
losses, injury, or death resulting from a failure to observe 
these safety precautions, misuse or abuse of pumps or 
equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Other brand and product names are trademarks or registered trademarks of their respective holders.
® Barnes is a registered trademark of Crane Pumps & Systems, Inc.
7/2004, 

8/04, 

5/06, 

9/06 

        Alteration 

Rights 

Reserved

E

N
G

L

I

S

H

Summary of Contents for QDX25-SS

Page 1: ...duct changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 118791 Rev D Series QDX25 SS 4NU10 25 HP 120 Volt Series QDX33 SS 4NU11 33 HP 120 Volt E S P A Ñ O ...

Page 2: ...ure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT remove c...

Page 3: ... N Hardware 300 series stainless steel CORD ENTRY 20 Ft 6m Cord with Plug Molded for strain relief and compression seal MOTOR Design Air Filled Insulation Class B SINGLE PHASE Permanent Split Capacitor PSC Includes Overload protection in motor PUMP SPECIFICATIONS inches mm Models QDX25 SS 4NU10 MODEL NO PART NO HP VOLT PH HERTZ RPM FULL LOAD AMPS QDX25 SS 118531 25 120 1 60 3450 2 0 QDX33 SS 11853...

Page 4: ...commended for general and light construction for sump and dewatering drainage for dewa tering manholes and transformer vaults for pit tunnel and trench dewatering and for flood fire and other emergency service cleanup Before pumping fluids other than water consult the factory giving fluid fluid temperature specific gravity viscosity capacity in USGPM and total head and or pressure requirements inc...

Page 5: ... NUT TIGHT CHECK FREQUENTLY There shall be no openings in the casing of the electrical parts The operating voltage shall match the voltage rating of the motor E 2 Cable Requirements Special care shall be taken in handling the cable against mechanical injury and wear Connections and wiring to the power source shall be in accordance with all electrical and safety codes SECTION F WARRANTY REPAIR F 1 ...

Page 6: ... operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate...

Page 7: ... of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND E...

Page 8: ... Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Cran...

Page 9: ... posible que se hagan cambios a los productos Por esta razón Crane Bombas y Sistemas se reserva el derecho de cambiar el producto sin previo aviso por escrito 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Teléfono 937 778 8947 Teléfono 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Formulario No 118791 Rev D Serie QDX25 SS y 4NU10 0 25 HP 120 Vol...

Page 10: ...No opere la bomba sin que las cubiertas y los dispositivos de seguridad estén instalados Ponga siempre en su lugar los dispositivos de seguridad que se hayan retirado durante el mantenimiento o reparaciones Fije la bomba en una posición estable de funcionamiento para que no se caiga hacia un lado al suelo o se deslice No exceda la recomendación del fabricante para obtener un funcionamiento superio...

Page 11: ...oxidable serie 300 ENTRADA DEL CORD Cordón con enchufe de 6m 20 pies Moldeado para reducción de tensión y sello de compresión MOTOR Diseño Lleno de aire aislamiento clase B MONOFASICO Capacitor permanentemente dividido PSC Incuye protección contra sobrecargas en el motor ESPECIFICACIONES DE LA BOMBA mm pulgadas Modelos QDX25 SS 4NU10 Modelo no No de pieza Hp Voltios Ph Hz Velocidad Amperios de car...

Page 12: ...es para drenaje de sumideros y extracción de agua para extracción de agua de salas de transformadores y de pasos de hombre para extracción de agua de pozos túneles y zanjas y para servicios de limpieza por inundaciones incendios u otras emergencias Antes de bombear otros líquidos distintos de agua onsulte con la fábrica y explique el tipo de líquido la temperatura del líquido la gravedad específic...

Page 13: ...nes óptimas MANTENGA APRETADA LA TUERCA ESTANCADORA DEL CABLE VERIFIQUE CON FRECUENCIA La carcasa de las partes eléctricas deberá estar libre de aberturas La tensión de funcionamiento deberá ser igual a la tensión nominal del motor E 2 Requisitos de cable Se debe tener cuidado especial al manejar el cable para evitar el desgaste y las lesiones producidos por acción mecánica Las conexiones y el cab...

Page 14: ...6 E S P A Ñ O L ...

Page 15: ... seguridad y las condiciones Limpie toda obstrucción de la cavidad del rotor y la entrada 9 Afloje la unión ligeramente para dejar que salga el aire atrapado Verifique que el nivel de apagado del interruptor se ha ajustado de forma que la cavidad del rotor siempre esté inundada Limpie el orificio de ventilación 10 Revise la rotación Si el suministro eléctrico es trifásico invierta dos o tres condu...

Page 16: ...se base en las especificaciones del funcionamiento debe existir por escrito y llevar la firma de nuestro representante autorizado Debido a errores en las pruebas fuera de fábrica si surge un conflicto entre los resultados de las pruebas fuera de fábrica realizadas por o para el usuario y las pruebas de laboratorio modificadas para funcionamiento fuera de fábrica éstas últimas tendrán validez sobre...

Page 17: ...para asegurarse que los empleados no se expongan a peligros para su salud al manipular dicho material Todas las leyes y reglamentos pertinentes tendrán validez IMPORTANTE REGISTRO DE LA GARANTIA Su producto está cubierto por la Garantía adjunta Para llenar el Formulario de Registro de la Garantía vaya a http www cranepumps com ProductRegistration Si usted tiene que hacer un reclamo bajo lo provist...

Page 18: ......

Reviews: