background image

Limited Warranty

We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects
in material and workmanship under normal use and service for the following time periods, when installed and maintained in
accordance with our instructions. 
Pump Products: One (1) year from date of installation or (24) twenty-four months from date of shipment, whichever occurs first.
Cleaning Products: Twelve (12) months from date of installation or eighteen (18) months from date of shipment, whichever
occurs first. As used herein, "the ultimate consumer" is defined as the purchaser who first uses the product after its initial
installation or, in the case of product designed for non permanent installation, the first owner who used the product. It is the
purchaser’s or any sub-vendee’s obligation to make known to the ultimate consumer the terms and conditions of this warranty.
This warranty gives you specific legal rights, and there may also be other rights which vary from state to state. In the event the
product is covered by the Federal Consumer Product Warranties Law (1) the duration of any implied warranties associated
with the product by virtue of said law is limited to the same duration as stated herein, (2) this warranty is a LIMITED WARRANTY,
and (3) no claims of any nature whatsoever shall be made against us, until the ultimate consumer, his successor, or assigns,
notifies us in writing of the defect, and delivers the product and/or defective part(s) freight prepaid to our factory or nearest
authorized service station. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation
may not apply. 

THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY AND ALL WARRANTIES WITH RESPECT

TO ANY PRODUCT SHALL BE TO REPLACE OR REPAIR AT OUR ELECTION, F.O.B. POINT OF MANUFACTURE OR
AUTHORIZED REPAIR STATION, SUCH PRODUCTS AND/OR PARTS AS PROVEN DEFECTIVE. THERE SHALL BE NO
FURTHER LIABILITY, WHETHER BASED ON WARRANTY, NEGLIGENCE OR OTHERWISE.

 Unless expressly stated

otherwise, guarantees in the nature of performance specifications furnished in addition to the foregoing material and
workmanship warranties on a product manufactured by us, if any, are subject to laboratory tests corrected for field performance.
Any additional guarantees, in the nature of performance specifications must be in writing and such writing must be signed by
our authorized representative. Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted
by or for user, and laboratory tests corrected for field performance, the latter shall control. Components or accessories supplied
by us but manufactured by others are warranted only to the extent of and by the terms and conditions of the original
manufacturer’s warranty. 

RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM

SYSTEMS ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE
AND PUBLISHED INDUSTRY INFORMATION. SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF
SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN.

This warranty shall not apply when damage is caused by (a) improper installation, (b) improper voltage (c) lightning (d) sand
or other abrasive material (e) scale or corrosion build-up due to excessive chemical content. Any modification of the original
equipment will also void the warranty. We will not be responsible for loss, damage or labor cost due to interruption of service
caused by defective parts. Neither will we accept charges incurred by others without our prior written approval.
This warranty is void if our inspection reveals the product was used in a manner inconsistent with normal industry practice
and\or our specific recommendations. The purchaser is responsible for communication of all necessary information regarding
the application and use of the product. 

UNDER NO CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR ANY OTHER

DIRECT OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED

 

TO LOST PROFITS, LOST INCOME, LABOR

CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION, WHICH DAMAGES ARE CAUSED BY ANY DEFECTS IN
MATERIAL AND\OR WORKMANSHIP AND\OR DAMAGE OR DELAYS IN SHIPMENT. THIS WARRANTY IS EXPRESSLY
IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTY, INCLUDING ANY WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE.

No rights extended under this warranty shall be assigned to any other person, whether by operation of law or otherwise, without
our prior written approval.

BARNES

®

420 Third Street/P.O. Box 603

83 West Drive, Brampton

Piqua, Ohio 45356-0603

Ontario, Canada L6T  2J6

Phone: (937) 778-8947

Phone: (905) 457-6223

Fax: (937) 773-7157

Fax: (905) 457-2650

www.cranepumps.com

PUMPS & SYSTEMS

A Crane Co. Company

Summary of Contents for 4SE-EDS Series

Page 1: ...product changes may occur As such Crane Pumps Systems Inc reserves the right to change product without prior written notification SERIES 4SE EL 1 5 6 7HP 1750 RPM SERIES 4SE EDS 1 5 6 7HP 1750 RPM BA...

Page 2: ...CROSS SECTION Fig 21 22 4SE EDS EXPLODED VIEW Fig 22 23 4SE EDS PARTS LIST 24 25 4SE EDS LEAK SENSOR PARTS LIST 26 4SE EDS LEAK SENSOR EXPLODED VIEW Fig 23 27 START UP REPORT WARRANTY INFORMATION WARR...

Page 3: ...arge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operat...

Page 4: ...Phase NEMA B Three Phase Torque Curve Completely Oil Filled Squirrel Cage Induction Insulation Class A SINGLE PHASE Dual Voltage 200 230 Includes Overload Protection In Motor 1 5 2 2HP Capacitor Start...

Page 5: ...e Completely Oil Filled Squirrel Cage Induction Insulation Class A SINGLE PHASE Dual Voltage 200 230 Includes Overload Protection In Motor 1 5 2 2HP Capacitor Start 2 7 4 5HP Capacitor Start Capacitor...

Page 6: ...ly If it is required that the pump be installed and tested before the long term storage begins such installation will be allowed provided 1 The pump is not installed under water for more than one 1 mo...

Page 7: ...or cools to a safe temperature In the event of an overload the source of this condition should be determined and rectified immediately DO NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION OCCURS...

Page 8: ...Resistance 5 Start wires Black White Main wires Black Red Pump rated for operation at 10 Voltage at Motor MODEL NO A DIM HP VOLT PH NEMA START CODE FULL LOAD AMPS LOCKED ROTOR AMPS CORD SIZE CORD TYP...

Page 9: ...hould be taken to an authorized service station However as with any mechanical piece of equipment a preventive maintenance program is recommended and suggested to include the following checks 1 Inspec...

Page 10: ...rated in cooler temperatures COOLING OIL Dielectric TABLE 1 SUPPLIER GRADE BP Enerpar SE100 CONOCO Pale Paraffin 22 MOBIL D T E Oil Light G G OIL Circulating 22 Imperial Oil Voltesso 35 Shell Canada T...

Page 11: ...Fig 4 DIAPHRAGM PLUG Material 2 000 Dia Aluminum Fig 5 DIAPHRAGM CLAMP Material 750W x 375Thk Steel Fig 6 OIL FILLING 11...

Page 12: ...e stationary member is in straight Lightly oil shaft and inner surface of bellows on rotating member With lapped surface of rotating member facing inward toward stationary member slide rotating member...

Page 13: ...with hole in drive and bell Press housing in place and temporarily install two mounting bolts 67 Place several drops of oil inside of bellows of rotating member 13C and spread it over bellows Coat se...

Page 14: ...Y PRESSING ON INNER RACE Support rotor assembly on ring see Figure 13 when installing top bearing so that the pressing force is not transmitted through balls of drive end bearing Place Tetraseal 43 on...

Page 15: ...Fig 15 SINGLE PHASE 1 5HP 2 2HP Fig 16 SINGLE PHASE 2 7HP 4 5HP Fig 17 THREE PHASE 15...

Page 16: ...cord 83 to each electrode with screws at top of electrode holder 90 See Figure 18 After the leak sensor has been reassembled with all screws and threaded hardware thoroughly tightened it must be check...

Page 17: ...lean impeller cavity and inlet of any obstruction 9 Loosen union slightly to allow trappedair to escape Verify that turn off level of switch is set so that impeller cavity is always flooded Clean vent...

Page 18: ...Fig 19 SERIES 4SE EL 18...

Page 19: ...Fig 20 SERIES 4SE EL 19...

Page 20: ...2 Pipe Plug Hex Hd 1 8 Brass 017363 13 1 Shaft Seal C CE B 4023 14 8 Hex Hd Screw 1 4 20 x 1 00 Lg Stainless 1 7 1 15 16 Lock Washer 1 4 Stainless 20 13 1 16 2 RdHd Screw 10 32 x 375 Lg Stainless 2 8...

Page 21: ...460 3PH N4019 03 2 7HP 230 1PH N4019 09 2 7HP 230 460 3PH N4019 04 4 5HP 230 1PH N4019 10 4 5HP 230 460 3PH N4019 05 6 7HP 230 460 3PH N4019 11 48 1 Ball Bearing 039734 49 1 Ball Bearing 625 00719 50...

Page 22: ...SERIES 4SE EDS Fig 21 22...

Page 23: ...SERIES 4SE EDS Fig 22 23...

Page 24: ...Plug Hex Hd 1 8 Brass 017363 13 1 Dbl Mech Shaft Seal C CE B 007 00500 13A 1 Retainer 13B 1 Spring 13C 1 Seal Face 13D 1 Seal Seat 14 8 Hex Hd Screw 1 4 20 x 1 00 Lg Stainless 1 7 1 15 18 Lock Washer...

Page 25: ...ng Ring 625 00266 51 1 Shell 1 5 2 2HP 2 7HP 3PH 4005 01 2 7HP 1PH 4 5HP 6 7HP 4005 02 52 1 Stator 1 5HP 115V 1PH 625 00755 1 5HP 208 230 1PH 625 00753 1 5HP 208 230 3PH 625 00748 1 5HP 460 3PH 625 00...

Page 26: ...84 1 Thread Protector 4651 85 1 Packing Nut 3 4 16 4697 3 86 2 Flat Washer 007 00301 87 1 Grommet 007 00302 88 6 RdHd Screw 8 32 x 625 Lg Stainless 9 65 1 89 1 Top Cover 4690 102 90 1 Electrode Holde...

Page 27: ...SERIES 4SE EDS Fig 23 27...

Page 28: ...eld performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field t...

Page 29: ...ottom Does Impeller Turn Freely By Hand YES NO Condition Of Equipment GOOD FAIR POOR Condition Of Cable Jacket GOOD FAIR POOR Resistance of Cable Jacket GOOD FAIR POOR Resistance of Cable and Pump Mot...

Page 30: ...Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks...

Page 31: ...Systems Inc Warranty Service Group IMPORTANT If you have a claim under the provision of the warranty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRE...

Page 32: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE...