Barnes 30MU Installation And Operation Manual Download Page 7

E-4) Impeller Shaft and Bearing Service:

Remove pump body, impeller, shaft seal and seal plate as
outlined in Section E-2 and E-3.

Pull slinger (24) from shaft (32). Remove cap screws (26)
and pull bearing cap (25) together with grease seal (30) from
bearing housing (34). Remove cap screws (36) and pull
bearing cap (35) together with grease seal (37) from bearing
housing (34). Remove bearing shims (27), (28) and (29). Tap
on drive end of shaft (32) with a block of wood and a hammer,
driving the shaft (32) together with the complete front bearing
(31) and the roller and cone of the back bearing (38) out of
the bearing housing (34). Examine bearings and grease
seals and replace if required.

If bearings are to be replaced, press bearing parts from shaft
and remove bearing cup from bearing housing by tapping
with a drift and a hammer. If grease seals are to be replaced,
press used seals out of bearing caps and replace. Press new
seals into bearing caps with patent number side out.

Place bearing cup for back bearing (38) into rear of bearing
housing (34). Be certain that the wide end of the cup taper is
facing the outside of the bearing housing. Press the cone and
roller of back bearing (38) onto drive end of shaft (32) seating
it snug against the shaft shoulder, with the taper running
toward impeller end of shaft. Press complete front bearing
(31) onto impeller end of shaft (32) seating it snug against
the shaft shoulder with the taper running toward drive end of
shaft.

Place assembled shaft and bearings into bearing housing
(34) key end first, bring the front bearing (31) into position
and press in place. If tight, use a sleeve and hammer to tap
into position. Replace back bearing cap (35) and grease seal
(37). Do not seat bearings too tight but make sure that a snug
fit is insured, yet permitting free movement of shaft in
bearings. Replace front bearing cap (25) and grease seal
(30) using required number of shims (27), (28) and (29) to
allow for a .005" shaft end play. Replace slinger (24) onto
shaft (32) before reassembling remainder of pump.

SECTION: F REPLACEMENT PARTS

F-1 ORDERING REPLACEMENT PARTS:

When ordering replacement parts, 

ALWAYS

 furnish the

following information:

1. Pump serial number and date code. (F-4)
2. Pump model number. (F-3)
3. Pump part number. (F-2)
4. Part description.
5. Item part number.
6. Quantity required.
7. Shipping instructions.
8. Billing instructions.

F-2 PART NUMBER:

The part number consists of a six (6) digit number, which
appears in the catalog. A one or two letter suffix may follow this
number to designate the design configuration. This number is
used for ordering and obtaining information.

F-3 MODEL NUMBER:

This designation consists of numbers and letters which
represent the discharge size, series horsepower, motor phase
and voltage, speed and pump design. This number is used for
ordering and obtaining information.

F-4 SERIAL NUMBER:

The serial number block will consist of a six digit number, which
is specific to each pump and may be preceded by a alpha
character, which indicates the plant location. This number will
also be suffixed with a four digit number, which indicates the
date the unit was built (Date Code). 

EXAMPLE:

 

A012345 0490.

Reference the six digit portion (Serial Number) of this number
when referring to the product.

3

1

2

7

Manual Index

HOME

MENU

Summary of Contents for 30MU

Page 1: ...ane Pumps Systems Inc reserves the right to change product without prior written notification Universal Drive Model 30MU BARNES 420 Third Street P O Box 603 83 West Drive Brampton Piqua Ohio 45356 060...

Page 2: ...LE SHOOTING 8 CROSS SECTION 9 EXPLODED VIEW 10 PARTS LIST 11 RETURNED GOODS POLICY 13 START UP REPORT WARRANTY REGISTRATION Other brand and product names are trademarks or registered trademarks of the...

Page 3: ...riate safety gear such as safety glasses when working on the pump or piping WARNING Keep clear of suction and discharge openings DO NOT insert fingers in pump with power on Always Wear Eye Protection...

Page 4: ...CHECK VALVE Material Valve Flap Neoprene Weights Cast Iron ASTM A 48 Class 30 OPTIONAL EQUIPMENT Seal Materials Case Heater Stainless Hardware High Temperature Control Flex Coupled Assy with Base OSHA...

Page 5: ...as near as possible to the liquid to be pumped and in no case should the pump be more than 25 feet above the surface of the liquid supply The pump should always be as level as possible All pump units...

Page 6: ...embly onto pump body make sure that HINGE section of gasket 3 is at TOP and that LARGE weight is on PUMP SIDE of gasket E 2 Body Wear Plate and Impeller Service To clean out or repair the body 10 wear...

Page 7: ...he front bearing 31 into position and press in place If tight use a sleeve and hammer to tap into position Replace back bearing cap 35 and grease seal 37 Do not seat bearings too tight but make sure t...

Page 8: ...alve strainer or pump 6 Defective wearplate s 1 Repair or replace suction line 2 Refill reprime pump casing before restarting 3 Lower suction head install foot valve and primer 4 Increase inlet pressu...

Page 9: ...9 Manual Index HOME MENU...

Page 10: ...10 Manual Index HOME MENU...

Page 11: ...mpeller 031266 18 2 Shim 010 001349 19 1 Shim 031 001348 20 1 Shaft Seal Carbon Ni Resist Buna N 019146 21 2 Gasket 003188 22 1 Gasket 003189 23 1 Seal Plate 011803 24 1 Slinger 005163 25 1 Bearing Ca...

Page 12: ...NOTES 12 Manual Index HOME MENU...

Page 13: ...nty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products...

Page 14: ...ance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a...

Page 15: ...allation Person in Charge Phone Purchased From Barnes Pumps Representative Distributor Pump Model Serial No Part Number Rotation Direction of Impeller Rotation Use C W for clockwise CC W for counter c...

Page 16: ...hase Voltage supply at panel line connection Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 Final Check Is pump...

Page 17: ...harge of Pump Phone Purchased from Crane Pumps Systems Representative Distributor Pumps Model Brand Part Number Trailer type Skid Mounted Contractor Trailer Highway Trailer Other Condition of Equipmen...

Page 18: ...Date I Certify this report to be accurate Name of Start Up person Employed by Date Date and Time of Start Up Present at Start Up Engineer Operator Contractor Other To be filled out by factory Start Up...

Page 19: ...T NO BRAND FOLD HERE IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and returned to Crane Pumps Systems Inc Warranty Service G...

Page 20: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE Manual Index HOME MENU...

Reviews: