background image

11

A Crane Co. Company

420 Third Street 

83 West Drive, Brampton

Piqua, Ohio 45356 

Ontario, Canada L6T 2J6

Phone: (937) 778-8947 

Phone: (905) 457-6223

Fax: (937) 773-7157 

Fax: (905) 457-2650

www.cranepumps.com

Limited 24 Month Warranty

Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship 
under normal use and service for twenty-four (24) months after manufacture date, when installed and maintained 
in accordance with our instructions.This warranty gives you specifi c legal rights, and there may also be other rights 
which vary from state to state. In the event the product is covered by the Federal Consumer Product Warranties Law 
(1) the duration of any implied warranties associated with the product by virtue of said law is limited to the same 
duration as stated herein, (2) this warranty is a LIMITED WARRANTY, and (3) no claims of any nature whatsoever 
shall be made against us, until the ultimate consumer, his successor, or assigns, notifi es us in writing of the defect, 
and delivers the product and/or defective part(s) freight prepaid to our factory or nearest authorized service station. 
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply. 

THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY AND ALL WARRANTIES WITH RESPECT TO ANY 
PRODUCT SHALL BE TO REPLACE OR REPAIR AT OUR ELECTION, F.O.B. POINT OF MANUFACTURE OR 
AUTHORIZED REPAIR STATION, SUCH PRODUCTS AND/OR PARTS AS PROVEN DEFECTIVE. THERE SHALL BE 
NO FURTHER LIABILITY, WHETHER BASED ON WARRANTY, NEGLIGENCE OR OTHERWISE.

 Unless expressly 

stated otherwise, guarantees in the nature of performance specifi cations furnished in addition to the foregoing material 
and workmanship warranties on a product manufactured by us, if any, are subject to laboratory tests corrected for 
fi eld performance. Any additional guarantees, in the nature of performance specifi cations must be in writing and such 
writing must be signed by our authorized representative. Due to inaccuracies in fi eld testing if a confl ict arises between 
the results of fi eld testing conducted by or for user, and laboratory tests corrected for fi eld performance, the latter 
shall control. 

RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS 

ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND 
PUBLISHED INDUSTRY INFORMATION. SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF 
SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN.

This warranty shall not apply when damage is caused by (a) improper installation, (b) improper voltage (c) lightning 
(d) excessive sand or other abrasive material (e) scale or corrosion build-up due to excessive chemical content. Any 
modifi cation of the original equipment will also void the warranty. We will not be responsible for loss, damage or labor 
cost due to interruption of service caused by defective parts. Neither will we accept charges incurred by others without 
our prior written approval.
This warranty is void if our inspection reveals the product was used in a manner inconsistent with normal industry practice 
and\or our specifi c recommendations. The purchaser is responsible for communication of all necessary information 
regarding the application and use of the product. 

UNDER NO CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR 

ANY OTHER DIRECT OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO TRAVEL EXPENSES, 
RENTED EQUIPMENT, OUTSIDE CONTRACTOR FEES, UNAUTHORIZED REPAIR SHOP EXPENSES, LOST 
PROFITS, LOST INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION, WHICH DAMAGES 
ARE CAUSED BY ANY DEFECTS IN MATERIAL AND\OR WORKMANSHIP AND\OR DAMAGE OR DELAYS IN 
SHIPMENT. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTY, 
INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

.

No rights extended under this warranty shall be assigned to any other person, whether by operation of law or otherwise, 
without our prior written approval.

Summary of Contents for 2020HC

Page 1: ...s Systems Inc constant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 104613 Rev G Model 2020HC Manual Index ...

Page 2: ...NED GOODS POLICY 11 WARRANT 12 START UP REPORT 13 15 WARRANTY REGISTRATION Other brand and product names are trademarks or registered trademarks of their respective holders Barnes is a registered trademark of Crane Pumps Systems Inc 1998 2002 10 04 4 06 9 06 Alteration Rights Reserved WARNING The engine exhaust from this product contains chemicals know to the State of California to cause cancer bi...

Page 3: ...de DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat When towing pump behind a vehicle make sure hitch is properly attached always attach safety chains WARNING If Engine driven never operate in an enclosed building or area where exhaust gases can accumulate Never operate near a building where exhaust gases can seep inside Never operate in ...

Page 4: ...lve Flap Neoprene Weights Cast Iron ASTM A 48 Class 30 BASE Steel with Carring Handles STRAINER 2 51mm Suction Steel PRIMER Exhaust with 0 150 PSI Compound Pressure and Vacuum Gauge ENGINE Make Model Briggs Stratton 245400 Gasoline Type 4 Cycle Single Cylinder Air Cooled Displacement 24 Cu In Oil Capacity 51 Fl Oz Air Cleaner Dual Element Fuel Tank 7 5 Quarts Start Method Recoil Rope Rated Max Dyn...

Page 5: ...ld be located as near as possible to the liquid to be pumped and in no case should the pump be more than 15 feet above the surface of the liquid supply The pump should always be as level as possible C 2 Suction System Connect suction pipe or hose to suction inlet If hose is used it should be of the reinforced type to prevent collapsing under suction Make sure all suction system connections are tig...

Page 6: ...intermediate coupling slide rotating member 9B onto shaft sleeve until lapped faces of 9A and 9B are together If finger pressure is not sufficient use a piece of tubing making sure to press ONLY on bellows tail section not on metal retainer See Figure 2 Make sure driving lugs in retainer are mated in carbon washer Place spring 9C on shaft sleeve and in place on rotating member 9B making sure it is...

Page 7: ...on head higher than pump designed for 4 Insufficient inlet pressure or suction head 5 Clogged foot valve strainer or pump 6 Defective wearplate s 1 Repair or replace suction line 2 Refill reprime pump casing before restarting 3 Lower suction head install foot valve and primer 4 Increase inlet pressure by adding more water to tank or increasing back pressure by turning gate valve on discharge line ...

Page 8: ...8 Figure 3 ...

Page 9: ...16 8 002501 Hex Nut 5 16 18 17 3 015000 Pipe Plug 375 NPT 18 1 021857 Check Valve Assy 18a 1 001338 Weight 2 25 Not Shown 18b 1 001339 Weight 1 56 Not Shown 18c 1 021577 Gasket Not Shown 18d 1 023469 RdHd Screw 1 4 20 x 625 Lg 19 1 021041 Check Valve Body 20 4 1 92 6 Capscrew 5 8 11 x 1 50 Lg 22 1 011113 Gage Compound 0 150 PSI 1 104823 Base Assy 24 1 021924 Base Channel LH 25 1 021925 Base Channe...

Page 10: ...22562 Lock Pin 187 Dia x 875 Lg H 1 2 22009 10 Pan Hd Self Tapping Screw 6 32 Steel I 1 104606 Tee Red 1 00 x 75 x 50 NPT CI J 1 104602 Adapter Assy K 1 011123 Union Half 375 NPT x 1 50 Lg Brass L 2 011124 Flare Nut 625 18 UNC 2B Brass M 1 104617 Tube 375 Dia x 18 Lg Copper N 1 022835 Tube Assy w Elbow 25 NPT O 1 104827 Gasket Graphite P 1 104826 Support Plate Steel Q 4 2 63 1 Rd Hd Screw 8 32 x 5...

Page 11: ...rformance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUAT...

Page 12: ...ent To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pump...

Reviews: