02

Specifications

DISCHARGE: 

   

 

6", 125lb, flange horizontal.

SPHERICAL SLD HNDLG: 

 

3"

LIQUID TEMPERATURE:

  

104° F (40° C) max.

VOLUTE:

  

 

 

Cast iron ASTM A-48 class 30.

WEAR RING:

   

 

Bronze. (Only for 6BSE-HLDS series)

MOTOR HOUSING:

  

 

Cast iron ASTM A-48 class 30.

SEAL PLATE:

    

 

Cast iron ASTM A-48 class 30.

IMPELLER:

 

 

 

6BSE-HLDS series

 

1 vane (2 for 48 and 60 HP and 3 for 

), closed, with vanes on back side.

Cast iron ASTM A-48 class 30.

SHAFT:

 

 

 

416 series stainless steel.

SQUARE RINGS:

 

 

Buna-N.

PAINT:

  

 

 

Air dry enamel, water based.

SEAL:   

 

 

Double mechanical, oil filled chamber. Silicon carbide outboard, carbon ceramic inboard 
seal, Buna-N elastomer and stainless steel hardware.

DIAPHRAGM:

   

 

Buna-N.

HARDWARE:

   

 

300 series stainless steel.

CORD ENTRY: 

 

 

25 ft of neoprene cord 2/4 G, sealed against moisture.

UPPER BEARING:

 

 

Ball, single row, oil lubricated, for radial load.

LOWER BEARING:

 

 

Ball, single row, oil lubricated, for radial and thrust load.

MOTOR:

 

 

 

Three phase, NEMA B, oil filled. Requires overload protection to be included in control 
panel. Class F insulation.

MOISTURE SENSOR:

   

Normally open (N/O) included.

TEMPERATURE SENSOR

Normally closed (N/C) included.

OPTIONAL EQUIPMENT:

 

Impeller trimming, additional cord, tungsten carbide seal, slide rail coupling (SRC-6).

The moisture cord and/or temperature cord is size 18/5, type SO, Ø0.485", for all models.

6BSE18034LDS 18

230

3

1750

50.6

232

F

2/3

G

1.34"

891

6BSE18044LDS 18

460

3

1750

25.3

116

F

2/3

G

1.34"

891

6BSE24034LDS 24

230

3

1750

62.8

290

E

2/3

G

1.34"

928

6BSE24044LDS 24

460

3

1750

31.4

145

E

2/3

G

1.34"

928

6BSE30034LDS 30

230

3

1750

75.8

364

E

2/3

G

1.34"

985

6BSE30044LDS 30

460

3

1750

37.9

182

E

2/3

G

1.34"

985

6BSE36034LDS 36

230

3

1750

90

434

E

2/3

G

1.34"

992

6BSE36044LDS 36

460

3

1750

45

217

E

2/3

G

1.34"

992

6BSE48034LDS 48

460

3

1750

65

290

E

2/3

G

1.34"

1014

6BSE60044LDS 60

460

3

1750

78

363

E

2/3

G

1.34"

1052

MODEL

HP VOLTS PHASE

RPM

(Nominal)

MAX

AMPS

LOCKED

ROTOR AMPS

NEMA

CODE

CORD

SIZE

CORD

TYPE

CORD

O. D.

WEIGHT

(pounds)

6BSE9036LDS

9

230

3

1150

26

162

F

2/3

G

1.34"

897

6BSE9046LDS

9

460

3

1150

13

81

J

2/3

G

1.34"

897

6BSE12036LDS 12

230

3

1150

36

162

D

2/3

G

1.34"

902

6BSE12046LDS 12

460

3

1150

18

81

F

2/3

G

1.34"

902

6BSE18036LDS 18

230

3

1150

50

232

C

2/3

G

1.34"

917

6BSE18046LDS 18

460

3

1150

25

116

F

2/3

G

1.34"

917

6BSE24036LDS 24

230

3

1150

64

290

C

2/3

G

1.34"

961

6BSE24046LDS 24

460

3

1150

32

145

E

2/3

G

1.34"

961

6BSE30036LDS 30

230

3

1150

82

364

C

2/3

G

1.34"

1008

6BSE30046LDS 30

460

3

1150

41

182

E

2/3

G

1.34"

1008

barmesapumps.com

Summary of Contents for 6BSE12036LDS

Page 1: ...s Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 6BSE LDS 6BSE HLDS 9 12 18 24 30 HP 1150 RPM 18 24 30 36 48 60 HP 1750 RPM 6BSE HLDS 30 60 HP 6BSE LDS 9 30 HP 18 60 HP Last update 08 07 2020 barmesapumps com ...

Page 2: ...ory items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduce risk of electric shock always disconnect pump from power source before DANGER handling any aspect of the pumping system Lockoutpowerandtag Do not lift carry or hang pump by the electric...

Page 3: ...seal sliderailcoupling SRC 6 The moisture cord and or temperature cord is size 18 5 type SO Ø0 485 for all models 6BSE18034LDS 18 230 3 1750 50 6 232 F 2 3 G 1 34 891 6BSE18044LDS 18 460 3 1750 25 3 116 F 2 3 G 1 34 891 6BSE24034LDS 24 230 3 1750 62 8 290 E 2 3 G 1 34 928 6BSE24044LDS 24 460 3 1750 31 4 145 E 2 3 G 1 34 928 6BSE30034LDS 30 230 3 1750 75 8 364 E 2 3 G 1 34 985 6BSE30044LDS 30 460 3...

Page 4: ... SIZE CORD TYPE CORD O D WEIGHT pounds 6BSE30034HLDS 30 230 3 1750 76 364 F 2 3 G 1 34 957 6BSE30044HLDS 30 460 3 1750 38 182 F 2 3 G 1 34 957 6BSE36034HLDS 36 230 3 1750 90 434 E 2 3 G 1 34 963 6BSE36044HLDS 36 460 3 1750 45 217 F 2 3 G 1 34 963 6BSE48044HLDS 48 460 3 1750 65 290 E 2 3 G 1 34 974 6BSE60044HLDS 60 460 3 1750 78 363 E 2 3 G 1 34 1005 46BSE HLDS 46BSE LDS barmesapumps com ...

Page 5: ...uplex stations or basins with a slide rail system Barmesa SRC which allows the pump s to be installed or removed without requiring personnel to enter the station or resting on the basin floor 4Discharge Piping Discharge piping should be as short as possible and sized no smaller than the pump discharge Do not reduce the discharge pipe size below that which is provided on the pump Both a check valve...

Page 6: ... phase information stamped on the pump name plate 2 Check Pump Rotation Improper motor rotation can result in poor pump performance and can damage the motor and or pump Check rotation on three phase units by momentarily applying power and observe the kickback Kickback should always be in a counter clockwise direction as viewed from motor end or opposite to impeller rotation Impeller rotation is co...

Page 7: ... box 4 to motor housing 3 Apply thread locking compound to cap screws 6 and place into holes and torque to 15 ft lbs Oil Replacement Seal Chamber Refill chamber completely full with new cooling oil or reuse the uncontaminated oil Figure 2 a Inspect motor chamber for oil level and contamination b Inspect impeller and body for excessive build up or clogging c Inspect motor bearings and shaft seal fo...

Page 8: ...nd bell from motor 1 Remove wave washer Remove upper bearing 2 with a wheel puller if damaged or worn Vertically lift stator 1 from rotor shaft Inspect windings for shorts and resistance Test the temperature sensors by checking for continuity between the black and white wires If defective contact factory or motor service station Pull motor rotor shaft with bearing 1 3 from bearing housing 1 Remove...

Page 9: ...r cap screws 25 Conduit Box Assembly Check power 38 and control cables 39 for crackes or damage and replace complete conduit box 4 if required See Figure 4 Bring motor wires through opening in top of motor housing 3 check sleeving and replace if damaged Position square ring 5 in conduit box 4 and reconnect leads using connectors and insulators See Figures 5 for wiring schematics Refill with coolin...

Page 10: ... should be approximately 0 012 inch 09 Service G T1 T7 T2 T8 T3 T9 T4 T5 T6 G L1 L2 L3 GREEN BLACK RED WHITE MOTOR LEADS THREE PHASE 230V AC Cable Motor Lead Number Green Green Black 1 and 7 Red 2 and 8 White 3 and 9 4 5 and 6 together Figure 5 T2 T3 T4 T7 T5 T8 T6 T9 G L2 L3 RED WHITE MOTOR LEADS T1 L1 BLACK G G GREEN THREE PHASE 460V AC Cable Motor Lead Number Green Green Black 1 Red 2 White 3 4...

Page 11: ...Figure 6 10 Repair Parts VOLUTE FOR 6BSE HLDS barmesapumps com For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List ...

Page 12: ...11 Parts List 46BSE LDS barmesapumps com 30400423 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List ...

Page 13: ...12 Parts List 46BSE HLDS barmesapumps com 30400423 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List ...

Page 14: ... supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible connector or tighten existing piping 14 Turn to automatic position 15 Check for leaks around basin inlet and outlets Pump will not turn off 2a Float movement restricted 2b Switch will not activate p...

Page 15: ......

Reviews: