Before installation, read the following 
instructions  carefully.  Failure  to 
follow 

instruction 

and 

safety 

information  could  cause  serious 
bodily  injury,  death  and/or  property 
damage.  Each  Barmesa  product  is 
carefully  inspected  to  insure  proper 
performance. Closely following these 
instructions  will  eliminate  potential 
operating  problems,  assuring  years 
of trouble-free service. 

01

General Safety Information

IMPORTANT! - Barmesa Pumps is not 
responsible  for  losses,  injury  or 
death  resulting  from  failure  to 
observe  these  safety  precautions, 
misuse,  abuse  or  misapplication  of 
pumps or equipment.

Installation,  wiring,  and 

j u n c t i o n   c o n n e c t i o n s   m u s t   b e   i n 
accordance  with  the  National  Electric 
Code  and  all  applicable  state  and  local 
codes. Requirements may vary depending 
on usage and location.

WARNING

I n s t a l l a t i o n   a n d 

servicing  is  to  be  conducted  by 
qualified personnel only.

WARNING

D o   n o t

  u s e   t h e s e 

pumps  in  water  over  104º  F. 

Do  not

 

exceed manufacturers recommended 
maximum performance, as this could 
cause the motor to overheat.

WARNING

Ground  Fault  Circuit 

Interrupter  (GFCI)  to  be  used  with 
plug-in type power cord.

WARNING

A L L   R E T U R N E D 
P R O D U C T S   M U S T   B E 
CLEANED,  SANITIZED,  OR

D E CO N TA M I N AT E D   P R I O R   TO 
SHIPMENT, TO INSURE EMPLOYEES 
WILL NOT BE EXPOSED TO HEALTH 
HAZ ARDS  IN  HANDLING  SAID 
MATERIAL. ALL APPLICABLE LAWS 
AND REGULATIONS SHALL APPLY.

Keep  clear  of  suction  and 
discharge  openings.  Do  not 
insert  fingers  in  pump  with

power connected; the rotating cutter 
and/or  impeller  can  cause  serious 
injury.

Always  wear  eye  protection 
when working on pumps. Do 
not wear loose clothing that

may  become  entangled  in  moving 
parts.

Pumps  build  up  heat 
and  pressure  during 
operation.  Allow  time 
f o r   p u m p s   t o   c o o l

DANGER

before  handling  or  servicing  the 
p u m p   o r   a n y   a c c e s s o r y   i t e m s 
associated with or near the pump.

T h i s   p u m p   i s   n o t 

i n t e n d e d   f o r   u s e   i n 
swimming  pools  or  water 
installations  where  there  is

DANGER

human contact with pumped fluid.

Risk of electric shock. To 

reduce risk of electric shock, 
always  disconnect  pump 
from  power  source  before

DANGER

handling any aspect of the pumping 
system.

 Lock out power and tag.

Do  not

  lift,  carry  or 

hang pump by the electrical 
c a b l e s .   D a m a g e   t o   t h e 
electrical  cables  can  cause

DANGER

shock, burns  or death. 

Never

 handle 

connected  power  cords  with  wet 
hands. Use appropriate lifting device.

S u m p   a n d   s e w a g e 

pumps often handle materials which 
could  cause  illness  or  disease.  Wear 
adequate  protective  clothing  when 
working  on  a  used  pump  or  piping. 
Never enter a basin after it has been 
used.

WARNING

Failure  to  permanently 

ground the pump, motor and 
controls  before  connecting 
to  power  can  cause  shock,

DANGER

burns or death.

These pumps are not to 

be  installed  in  locations 
classified  as  hazardous  in 
accordance with the National

Electric Code, ANSI/NFPA 70.

DANGER

The  Uniform  Plumbing 

Code  (U P C )  states  that  sewage 
systems shall have an audio and visual 
alarm that signals a malfunction of the 
systems,  that  are  required  to  reduce 
the potencial for property damage.

WARNING

1 Phase Models

Amps:

Volts:

3 Phase Models

Amps L1-2:

Volts L1-2:

Amps L2-3:

Volts L2-3:

Amps L3-1:

Volts L3-1:

Model Number: _____________________

Serial: ____________

PHASE: ______ HP: __________________

IMPORTANT!  -  Prior  to  installation, 
record  Model  Number,  Serial,  Amps, 
Voltage,  Phase  and  HP  from  pump 
name  plate  for  the  future  reference. 
Also  record  the  Voltage  and  Current 
Readings at Startup:

WARNING

 "Danger" indicates an 

imminently  hazardous  situation 
which, if not avoided, WILL result in 
death or serious injury.

"Warning"  indicates 

an  imminenty  hazardous  situation 
which, if not avoided, MAY result in 
death or serious injury.

"Caution"  indicates  a 

potentially  hazardous  situation 
which, if not avoided, MAY result in 
minor or moderate injury.

DANGER

CAUTION

barmesapumps.com

Summary of Contents for 6BSE12036LDS

Page 1: ...s Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 6BSE LDS 6BSE HLDS 9 12 18 24 30 HP 1150 RPM 18 24 30 36 48 60 HP 1750 RPM 6BSE HLDS 30 60 HP 6BSE LDS 9 30 HP 18 60 HP Last update 08 07 2020 barmesapumps com ...

Page 2: ...ory items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduce risk of electric shock always disconnect pump from power source before DANGER handling any aspect of the pumping system Lockoutpowerandtag Do not lift carry or hang pump by the electric...

Page 3: ...seal sliderailcoupling SRC 6 The moisture cord and or temperature cord is size 18 5 type SO Ø0 485 for all models 6BSE18034LDS 18 230 3 1750 50 6 232 F 2 3 G 1 34 891 6BSE18044LDS 18 460 3 1750 25 3 116 F 2 3 G 1 34 891 6BSE24034LDS 24 230 3 1750 62 8 290 E 2 3 G 1 34 928 6BSE24044LDS 24 460 3 1750 31 4 145 E 2 3 G 1 34 928 6BSE30034LDS 30 230 3 1750 75 8 364 E 2 3 G 1 34 985 6BSE30044LDS 30 460 3...

Page 4: ... SIZE CORD TYPE CORD O D WEIGHT pounds 6BSE30034HLDS 30 230 3 1750 76 364 F 2 3 G 1 34 957 6BSE30044HLDS 30 460 3 1750 38 182 F 2 3 G 1 34 957 6BSE36034HLDS 36 230 3 1750 90 434 E 2 3 G 1 34 963 6BSE36044HLDS 36 460 3 1750 45 217 F 2 3 G 1 34 963 6BSE48044HLDS 48 460 3 1750 65 290 E 2 3 G 1 34 974 6BSE60044HLDS 60 460 3 1750 78 363 E 2 3 G 1 34 1005 46BSE HLDS 46BSE LDS barmesapumps com ...

Page 5: ...uplex stations or basins with a slide rail system Barmesa SRC which allows the pump s to be installed or removed without requiring personnel to enter the station or resting on the basin floor 4Discharge Piping Discharge piping should be as short as possible and sized no smaller than the pump discharge Do not reduce the discharge pipe size below that which is provided on the pump Both a check valve...

Page 6: ... phase information stamped on the pump name plate 2 Check Pump Rotation Improper motor rotation can result in poor pump performance and can damage the motor and or pump Check rotation on three phase units by momentarily applying power and observe the kickback Kickback should always be in a counter clockwise direction as viewed from motor end or opposite to impeller rotation Impeller rotation is co...

Page 7: ... box 4 to motor housing 3 Apply thread locking compound to cap screws 6 and place into holes and torque to 15 ft lbs Oil Replacement Seal Chamber Refill chamber completely full with new cooling oil or reuse the uncontaminated oil Figure 2 a Inspect motor chamber for oil level and contamination b Inspect impeller and body for excessive build up or clogging c Inspect motor bearings and shaft seal fo...

Page 8: ...nd bell from motor 1 Remove wave washer Remove upper bearing 2 with a wheel puller if damaged or worn Vertically lift stator 1 from rotor shaft Inspect windings for shorts and resistance Test the temperature sensors by checking for continuity between the black and white wires If defective contact factory or motor service station Pull motor rotor shaft with bearing 1 3 from bearing housing 1 Remove...

Page 9: ...r cap screws 25 Conduit Box Assembly Check power 38 and control cables 39 for crackes or damage and replace complete conduit box 4 if required See Figure 4 Bring motor wires through opening in top of motor housing 3 check sleeving and replace if damaged Position square ring 5 in conduit box 4 and reconnect leads using connectors and insulators See Figures 5 for wiring schematics Refill with coolin...

Page 10: ... should be approximately 0 012 inch 09 Service G T1 T7 T2 T8 T3 T9 T4 T5 T6 G L1 L2 L3 GREEN BLACK RED WHITE MOTOR LEADS THREE PHASE 230V AC Cable Motor Lead Number Green Green Black 1 and 7 Red 2 and 8 White 3 and 9 4 5 and 6 together Figure 5 T2 T3 T4 T7 T5 T8 T6 T9 G L2 L3 RED WHITE MOTOR LEADS T1 L1 BLACK G G GREEN THREE PHASE 460V AC Cable Motor Lead Number Green Green Black 1 Red 2 White 3 4...

Page 11: ...Figure 6 10 Repair Parts VOLUTE FOR 6BSE HLDS barmesapumps com For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List ...

Page 12: ...11 Parts List 46BSE LDS barmesapumps com 30400423 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List ...

Page 13: ...12 Parts List 46BSE HLDS barmesapumps com 30400423 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List ...

Page 14: ... supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible connector or tighten existing piping 14 Turn to automatic position 15 Check for leaks around basin inlet and outlets Pump will not turn off 2a Float movement restricted 2b Switch will not activate p...

Page 15: ......

Reviews: