8
Note:
When choosing where to install the
appli- ance, make sure that:
-
the room temperature never drops below
10°C
(50°F)
and does not exceed
43°C
(110°
F)
-
the water temperature must be no less than
10°C
(50°F)
and no more than
32°C
(90°F)
(fig.
2).
Fig. 2
-
the supply water pressure must be no less than
0,1 MPa (1 bar) and no more than 0,5 MPa (5
bar). Should the pressure exceed 0,5 MPa, install a
pres- sure reducer on the machine water supply
(fig. 3).
5.
Install the water connections before the
electrical connections.
6.
Connect the 3/4’’ supply pipe (supplied) to the
machine and to the cold drinking water supply
line.
For practical and safety purposes, it is advisable
to install a shut-off valve (not supplied) (fig. 5:
1.
switch; 2. socket; 3. electrical plug; 4.water
sup- ply; 5. valve; 6. water drain from the
condenser: water-cooled version; 7. water drain
from the con- tainer; 8. water drain with open
siphon).
Fig. 5
7.
Apply the flexible pipe (supplied) with a 20 mm
EN
inner diameter and of adequate length (not more
Fig. 3
- the machine is away from heat sources and in
a
wellventilated area (fig. 4).
Fig. 4
CONNECT ONLY TO THE DRINKING WATER MAINS.
than 1 metre from the machine) to the water
drain fitting of the machine in order to reach the
drain well.
Note: Install the machine in a position that the
ventilation of the cooling unit is not obstructed
in any way (only for air-cooled machines) (fig. 6).
Fig. 6
-
Do not install the machine in a dusty room
as the condenser of the cooling unit can be
easily clogged (only for air-cooled machines)
(fig. 6))