7.6 Mechanical
Housing
Aluminum case, with mounting wings (4 mounting holes 6.4 mm / 0.25“ diameter)
Weight
280 grams / 9.88 oz. (without any cables/connectors)
Dimensions
Parameter
Width
Height
Depth
Unit
Device enclosure
108
4.25
38
1.5
78.8
3.1
mm
inch
Including mounting wings and
built-in connectors
138
5.43
47
1.85
78.8
3.1
mm
inch
Including external plugs (approx.)
138
5.43
47
1.85
142.8
5.62
mm
inch
Including external plugs and cables
(approx.)
138
5.43
47
1.85
239
9.4
mm
inch
7.7 MTBF Calculations
Parameter
Value
Unit
MTBF calculated according to
MIL217F
-
Calculated Supply Voltage
48
VDC
Calculated Temperature (ambient)
25
77
° C
° F
Calculated Temperature (inside device)
40
104
° C
° F
Calculation for Ground Mobile Device
n.a.
hours
Calculation for Ground Fix Device
250'000
hours
7.8 Environmental
Parameter
Value
Unit
Operating Temperature Range
0..55
32..131
° C
° F
Operating Humidity Range (non-condensing)
0..70
%
Storage Temperature Range
0..70
32..158
° C
° F
Storage Humidity Range (non-condensing)
0..70
%
7.9 Certifications / Compliances
Type
Certifications/Compliances
Complies with
RoHS, FCC B, CE B, C-Tick, UL (planned)
Immunity according to
EN55024, EN61000-4-2,-4-3,-4-4,-4-5,-4-6
Emissions according to
EN 55022
Product Safety according to
EN 60590
BARIX AG |
24/26