background image

MAC Address

The MAC address of the device is printed on the label placed below the data plate sticker on
the bottom of the device.

Two additional MAC address stickers come with the device, one intended for placing on the
top of the device before mounting and cabling and one for documentation purposes.

3.7 Device Status LEDs

The green and red LEDs 

 B 

 are used to signal the current status of the device. For a detailed

description of the different LED states please refer to the corresponding software manual.

The green and red device status LEDs are directly connected to the IP Audio Module.

3.8 Reset button

An reset push button 

 A 

 is directly connected to “software reset“ input of the IP Audio Module.

Intended use : reset (reboot) / factory defaults (see software manual for details).

BARIX AG | 

14/26

Both LEDs:
On, Off, Blinking depending on loaded software

Summary of Contents for Extreamer P5

Page 1: ...PoE powered Document version 01 01 Release date 28 Apr 2011 Hardware Rev HW 1 0 2011 Barix AG all rights reserved All information is subject to change without notice All mentioned trademarks belong to their respective owners and are used for reference only EXSTREAMER P5 ...

Page 2: ... contents 7 2 3 Firmware 7 2 4 Support 7 2 5 Front view 8 A Reset button 8 B Status LEDs 8 C Control interface RJ45 8 2 6 Rear view 8 D Speaker output Plug b 8 E Ethernet port 10 100 PoE RJ 45 8 2 7 Installation 9 2 8 Network configuration by web browser 9 2 9 Setting temporary IP address using the MAC address 10 2 10 Troubleshooting 10 3 Hardware 11 3 1 Introduction 11 3 2 Functional block diagra...

Page 3: ... device 15 5 Updating the device 17 5 1 Introduction 17 5 2 Checking the Current Version 17 Version information 17 5 3 Downloading the latest firmware 18 Introduction 18 Standard Firmware 18 ABCL Firmware Applications 18 5 4 Web Update Procedure 18 Note on Factory Defaults 20 6 Mechanical Informations 21 6 1 Dimensions and Weight 21 6 2 Space requirements 21 6 3 Mounting 21 6 4 Thermal considerati...

Page 4: ...ocessor Codec 24 Speaker output and D A Conversion 24 Built in Parts 24 7 6 Mechanical 25 Housing 25 Weight 25 Dimensions 25 7 7 MTBF Calculations 25 7 8 Environmental 25 7 9 Certifications Compliances 25 8 Ordering Information 26 8 1 Exstreamer P5 NoPSU Package 26 9 Legal Information 27 Table of Contents iv ...

Page 5: ... to in store from distribution of music in hotelsto SIP telephone paging applications 1 4 Applications Overhead Speaker Interface with Amplifier Commercial audio streaming applications Playback point in an IP PA system In room IP Device for Hotels Venues In store audio distribution SIP based paging interface Zone output device for IP distributed audio Ethersound ES 100 Spkr channel receiver 1 5 Ha...

Page 6: ...ded with different firmware packages featuring Embedded and robust operating system with fully routable IP stack IP standard based protocols TCP IP UDP HTTP ICMP SNMP Supports BootP DHCP Auto IP and IPzator Integrated web server for configuration control update and streaming functions Fully documented Application Programming Interface API Highly customizable User Interface HTML with development ki...

Page 7: ... To complete the installation please read also the following chapters 2 2 Package contents a Exstreamer P5 b Screw block terminal connector 2 pin for speaker c Quick install guide 2 3 Firmware This device comes preloaded with the Streaming Client firmware Alternative firmware such as the iClient ABCL application can be downloaded from www barix com 2 4 Support For support please contact your local...

Page 8: ...le with VSC Volume Source Control unit Pin Description 1 Not connected 2 Not connected 3 Ground GND 4 RS 485 B 5 RS 485 A 6 IR signal input 7 Ground GND 8 V 10V 100mA max 2 6 Rear view D Speaker output Plug b Pin Description 1 Speaker 2 Speaker E Ethernet port 10 100 PoE RJ 45 Standard RJ45 Ethernet socket with PoE power 802 3af input Pin Description 1 Tx PoE a 2 Tx PoE a 3 Rx PoE a 4 PoE b 5 PoE ...

Page 9: ...atches your device see label on the bottom of the device STEP 5 If you intend to use a VSC Volume Source Control unit plug a standard straight network cable not included into the control port C of the Exstreamer and the other end into your VSC unit Now that you know the IP address proceed to section 2 8 Network configuration by web browser If you were not able to obtain the device s current IP add...

Page 10: ...6 00 08 E1 00 B1 77 or on a OSX or Linux system type into the terminal arp s 192 168 0 6 00 08 E1 00 B1 77 and hit the Enter key replace the digits according to your devices MAC address You must have administrative rights to be able to do so sudo on OSX Linux STEP 5 Now we have to make the Exstreamer listen to the IP address 192 168 0 6 using the Telnet command To do so type into the command windo...

Page 11: ...onal blocks using the below block diagram starting on the top left and working down each interface to the point where it is connected to the IP audio module We then do the same from the top right corner At the same time you will find for each connector informations on how to wire the Barix Exstreamer P5 to external components We will explain the wiring using the wiring diagram on the next page The...

Page 12: ...supply self resetting fuse 100mA and Ground intended for powering an external device consuming less than 1 Watt To connect to an external RS 485 device or bus a male RJ 45 connector is needed To connect a Barix VSC Volume Source Controller a standard Cat 5 cable can be used BARIX AG 12 26 3 C 4 5 5 VSC Volume Source Control GND B A IR Out 7 GND 8 10V 6 3 C 4 5 8 RS 485 Device GND B A 10V ...

Page 13: ...verall consumption is rated 15 Watts max Power will be accepted on pins 1 2 Pa against pins 3 6 Pa or alternatively on pins 4 5 Pb against pins 7 8 Pb A standard network cable Cat 5 or higher not included must be used to ensure proper network and power functionality Status LEDs The port features status LEDs F The green LED shows the ports link status On when the link is up off when the link is dow...

Page 14: ...Ds The green and red LEDs B are used to signal the current status of the device For a detailed description of the different LED states please refer to the corresponding software manual The green and red device status LEDs are directly connected to the IP Audio Module 3 8 Reset button An reset push button A is directly connected to software reset input of the IP Audio Module Intended use reset rebo...

Page 15: ...ll reboot immediately This command uses the HTTP web server port default 80 Supply the correct port number if you change this setting TCP Interface Send the command c 99 followed by a CR Carriage Return character in a TCP packet to the device The device will reboot immediately This command uses the TCP command port which is disabled by default default 0 Enable the command port first and send the p...

Page 16: ...ces firmware and reverting settings to factory defaults Please keep that in mind when planning a remote Update over network 5 2 Checking the Current Version To find out which version is currently installed check the informations next to the Barix logo on the devices main web page using a standard browser Version information Firmware shows the version and the release date of the loaded firmware Web...

Page 17: ...user manual with the same versions as the Streaming Client Update Kit that you downloaded in previous step and read carefully before continuing with an upload to the device ABCL Firmware Applications To download a firmware version please visit www barix com In the menu on the left side click on downloads In the the center column under section Special Applications click on ABCL Applications overvie...

Page 18: ... STEP 5 Click on Browse to select the file you want to update The file is named compound bin located in the folder update_rescue Select the file and click on the Open button STEP 6 Click on Upload to start the upload process which will take approximately 2 minutes After a successful upload the following window appears STEP 7 Click on the update link and then click on the Reboot button in the follo...

Page 19: ...y Defaults The Web Update procedure does not change the current configuration Barix recommends nevertheless checking for correct parameters in the configuration as well as to set parameters for newly added features If you observe strange behavior after an update Barix recommends resetting the configuration to factory defaults see chapter Reverting to Factory Defaults in the according User Manual a...

Page 20: ...ximately 11 mm 0 43 and therefore increases the overall physical depth to 90 mm 3 54 Standard Cat 5 cable plugs stick out 32 mm 1 26 Depending on the plugs used and the suggested bending radius of the cables used on each side the overall spacing depth is increased twice by approximately 80 mm 3 15 6 to a total of 239 mm 9 4 6 3 Mounting For mechanical fixation the Barix Exstreamer P5 features moun...

Page 21: ...an operating temperature range of 0 55 C 32 131 F Nevertheless an adequate space around the enclosure is needed to allow for sufficient air flow in order to prevent overheating especially when mounted in racks with higher power consumption devices or in a high temperature environment BARIX AG 21 26 ...

Page 22: ...af Status display Link Activity LED Protocols TCP IP UDP RTP SIP DHCP 7 4 Serial Interfaces Parameter RS 232 internal only RS 485 COM 1 Connector type Internal 8 pin header J2 RJ 45 female socket Signals RxD TxD RTS CTS all TTL level RS 485 receive enable 3 3VDC GND A B 10VDC 100mA GND IR remote signal input Baud rates 300 230400 300 230400 Data bits 7 or 8 7 or 8 Parity No Even Odd No Even Odd St...

Page 23: ... to peak 8 Ohm load 18 86 6 67 VPP VRMS Max output power on 8 Ohm speaker 5 56 WRMS Frequency response 3dB 48 kHz sample rate PCM 20 11 600 Hz Frequency response with treble 2 0 5dB 5 kHz 20 13 000 Hz Frequency response with treble 3 1 4dB 7 kHz 20 15 000 Hz Output signal to noise ratio SNR 90 dB Dynamic Range 90 dB Total Harmonic Distortion THD 3dBFS 2 8W 0 665 Total Harmonic Distortion THD 0 4dB...

Page 24: ...TBF calculated according to MIL217F Calculated Supply Voltage 48 VDC Calculated Temperature ambient 25 77 C F Calculated Temperature inside device 40 104 C F Calculation for Ground Mobile Device n a hours Calculation for Ground Fix Device 250 000 hours 7 8 Environmental Parameter Value Unit Operating Temperature Range 0 55 32 131 C F Operating Humidity Range non condensing 0 70 Storage Temperature...

Page 25: ...8 Ordering Information 8 1 Exstreamer P5 NoPSU Package Barix ordering number 2010 9104 Package contents Exstreamer P5 Screw block terminal connector 2 pin for speaker Quick Install Guide BARIX AG 25 26 ...

Page 26: ...emarks of Barix AG Switzerland and are registered in certain countries Newest information about our devices is available via download from our website www barix com We explicitly reserve the right to change and improve the product without notice Barix AG Seefeldstrasse 303 8008 Zürich SWITZERLAND T 41 43 433 22 11 F 41 44 274 28 49 www barix com sales barix com support barix com BARIX AG 26 26 ...

Reviews: