background image

         WARNING

Read and follow all safety information in this manual, operating instructions and

furnace safety labels.  Failure to follow safety precautions could result in damage,

injury or death.

• Do not store or use gasoline or other flammable vapors and liquids in the

       vicinity of  this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS
    • Do not try to light any appliance.
    • Do not touch any electrical switch; do not use any phone in your building.
    • Immediately call your gas supplier from a neighbor's phone.  Follow the gas
        supplier's instructions.
    • If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer or the gas

      supplier.

          WARNING

If the information in this manual is not followed exactly, a fire or explosion may

result causing property damage, personal injury or loss of life

IMPORTANT SAFETY NOTE:  You must know how to turn off gas and electricity to air conditioner/gas
furnace.  Your qualified installer, service agency or gas supplier can teach you to use controls and switches.

Thank you for reading these safety statements.  Please read on so you will know

how to maintain your air conditioner/gas furnace for years of dependable service.

We're pleased you've chosen our air conditioner/gas furnace to supply your cooling/heating needs.  Please
keep this manual in a safe, yet readily available place.  It contains important and useful information.

ATTENTION, INSTALLER:  After installing air conditioner/gas furnace, give the user:

• User's Information Manual

• Parts List

• Installation Instructions

• Warranty Information

ATTENTION, USER!  Your installer should give you the above four important documents relating to your
air conditioner/gas furnace.  Keep these as long as you do your equipment.  Pass these documents on to later
purchasers or furnace users.  If any of the four documents are missing or damaged, contact your installer or
manufacturer for replacement.  For efficient service, please give your unit model and serial number, from
Section 1 or from your serial rating plate.

USER'S INFORMATION MANUAL

WG-Series Combination Gas/Electric Wall-Mount

Manual:

2100-366A

Supersedes:

2100-366

File:

Vol I, Tab 20

Date:

07-10-00

BARD MANUFACTURING COMPANY
Bryan, Ohio 43506

Since 1914...Moving ahead, just as planned.

         WARNING

Do not use this air conditioner/gas furnace if any part has been under water.  Immedi-

ately call a qualified service technician to inspect the unit and to replace any part of the

control system and any gas control which has been underwater.

Summary of Contents for WG-Series

Page 1: ...nditioner gas furnace for years of dependable service We re pleased you ve chosen our air conditioner gas furnace to supply your cooling heating needs Please keep this manual in a safe yet readily ava...

Page 2: ...r Conditioning Start Up Procedure Crankcase Heater 12 Section 8 Ventilation Options 12 Section 9 Replacement Parts 13 Section 10 Outdoor Coil 13 Figures Figure 1 Typical Gas Piping 6 Figure 2 Step by...

Page 3: ...____________ Model Number _______________________________________________________________ Serial Number _______________________________________________________________ Date Installed _________________...

Page 4: ...s or vapors near or on your furnace These include gasoline kerosene cigarette lighter fluid cleaning fluids solvents paint thinners or painting compounds Flammable vapors can travel great distances be...

Page 5: ...rs There is a 60 second delay after main burner is on until the comfort air blower starts on heating speed After the thermostat is satisfied the burners will go off as gas valve closes The inducer wil...

Page 6: ...ut Alarm terminal on Compressor Control Module is 24V AC output connection for applications where signal is desired This terminal is powered whenever compressor is in manual lockout due to high pressu...

Page 7: ...r or Propane LP Gas Tank Normally natural gas is ON when you turn shut off parallel to gas pipe Gas is OFF when you turn shut off 90 from gas pipe Some valves require a wrench or other tools 2 ELECTRI...

Page 8: ...Manual 2100 366 Page 6 FIGURE 1 TYPICAL GAS PIPING MIS 1478...

Page 9: ...condition indicates lack of airflow through furnace ACTION a Make sure air filter is clean and installed correctly b Check that registers and return air grilles are open and unobstructed c If conditio...

Page 10: ...R FURNACE 1 Do not try to light main burners 2 Do not touch or turn on any electrical switch 3 Do not use any phone in your building 4 Immediately call your gas supplier from a neighbor s phone Follow...

Page 11: ...Manual 2100 366 Page 9 FIGURE 2 START UP PROCEDURE...

Page 12: ...of deterioration of the furnace 6 Periodic examinations of the vent terminal should also be conducted by the owner on a regular basis preferably every month but at least every two months during the he...

Page 13: ...Manual 2100 366 Page 11 FIGURE 4 PERIODIC INSPECTIONS MIS 1449 FIGURE 3 FILTER LOCATIONS MIS 1447a...

Page 14: ...is very important Please read carefully IMPORTANT These procedures must be followed at ini tial start up and at any time power has been removed for 12 hours or longer To prevent compressor damage whi...

Page 15: ...ered by these instructions it is very important to always supply the complete model number and serial number of the unit This is necessary to assure that the correct parts or an approved alternate par...