Getting Other Information and Publications

These publications can help you install the air conditioner
or heat pump. You can usually find these at your local
library or purchase them directly from the publisher. Be
sure to consult current edition of each standard.

National Electrical Code ......................... ANSI/NFPA 70

Standard for the Installation ................. ANSI/NFPA 90A
of Air Conditioning and
Ventilating Systems

Standard for Warm Air ........................ ANSI/NFPA 90B
Heating and Air
Conditioning Systems

Load Calculation for .............................. ACCA Manual J
Residential Winter and
Summer Air Conditioning

Duct Design for Residential .................. ACCA Manual D
Winter and Summer Air
Conditioning and Equipment
Selection

For more information, contact these
publishers:

ACCA — Air Conditioning Contractors of America

1712 New Hampshire Avenue NW
Washington, DC 20009
Telephone: (202) 483-9370
Fax: (202) 234-4721

ANSI — American National Standards Institute

11 West Street, 13th Floor
New York, NY 10036
Telephone: (212) 642-4900
Fax: (212) 302-1286

ASHRAE — American Society of Heating Refrigerating,

& Air Conditioning Engineers, Incorporated
1791 Tullie Circle, N.E.
Atlanta, GA 30329-2305
Telephone: (404) 636-8400
Fax: (404) 321-5478

NFPA — National Fire Protection Association

Batterymarch Park
P.O. Box 9101
Quincy, MA 02269-9901
Telephone: (800) 344-3555
Fax: (617) 984-7057

Manufactured under the following U.S. patent numbers:

5,485,878; 5,301,744; 5,002,116; 4,924,934; 4,875,520;
4,825,936; 4,432,409

Summary of Contents for WA181

Page 1: ...0 200J File Volume III Tab 16 Date 04 19 99 Bard Manufacturing Company Bryan Ohio 43506 Since 1914 Moving ahead just as planned Copyright 1999 MIS 656 Models WA181 WA241 Wall Mounted Packaged Air Cond...

Page 2: ...Blade Setting 14 Tables Table 1 Electric Heat Table 2 Table 2 Electrica Specifications 4 Table 3 Thermostat Wire Size 7 Table 4 Wall Thermostat and Subbase Combinations 7 Table 5 Fan Blade Dimensions...

Page 3: ...al D Winter and Summer Air Conditioning and Equipment Selection For more information contact these publishers ACCA Air Conditioning Contractors of America 1712 New Hampshire Avenue NW Washington DC 20...

Page 4: ...ROL MODULES COIL OPTIONS X Standard 1 Phenolic Coated Evaporator 2 Phenolic Coated Condenser 3 Phenolic Coated Evaporator and Condenser OUTLET OPTIONS X Front Standard T Top on WA30 and WA36 Models NO...

Page 5: ...F G I J K L M N O P Q R S T A B C B 8 1 A W 4 2 A W 0 0 3 3 3 5 2 1 7 1 3 6 5 0 7 8 8 7 8 8 9 1 8 8 1 1 8 8 9 1 0 0 5 3 0 5 8 1 5 7 5 2 6 5 0 2 5 7 6 2 6 0 8 2 5 2 9 2 0 0 7 2 3 6 2 3 1 4 3 6 0 2 2 5...

Page 6: ...0 6 2 1 0 1 0 1 8 6 2 1 0 1 0 1 0 1 0 1 Z 0 B 0 0 B 1 4 2 A W 6 0 B 3 8 0 2 0 3 2 1 1 3 1 2 2 5 1 5 2 4 1 0 1 2 1 0 1 S Q R Maximum size of the time delay fuse or HACR type circuit breaker for protec...

Page 7: ...is an excellent guide to proper sizing All duct work or portions thereof not in the conditioned space should be properly insulated in order to both conserve energy and prevent condensation or moistur...

Page 8: ...of Energy Energyguide Fact Sheets is based upon the fresh air blank off plate in place and is recommended for maximum energy efficiency The blank off plate is available upon request from the factory a...

Page 9: ...b b u S s e r u t a e F e t a n i m o d e r P 2 0 0 3 0 4 8 1 1 1 3 F 7 8 T 3 0 0 4 0 4 8 0 2 2 1 A 9 3 5 Q l o o c e g a t s 1 t a e h e g a t s 1 n o o t u a n a F l o o c f f o t a e h m e t s y S...

Page 10: ...100 200 Page 8 FIGURE 3 MOUNTING INSTRUCTIONS MIS 353 NOTE It is recommended that a bead of silicone caulking be placed behind the side mounting flanges and under the top flashing at the time of insta...

Page 11: ...Page 9 FIGURE 4 WALL MOUNTING INSTRUCTIONS MIS 549 FIGURE 5 WALL MOUNTING INSTRUCTIONS MIS 548 SEE FIGURE 3 MOUNTING INSTRUCTIONS SEE UNIT DIMENSIONS FIGURE 1 FOR ACTUAL DIMENSIONS SEE FIGURE 1 FOR D...

Page 12: ...Manual 2100 200 Page 10 MIS 550 FIGURE 6 COMMON WALL MOUNTING INSTALLATIONS...

Page 13: ...Manual 2100 200 Page 11 FIGURE 7 LOW VOLTAGE WIRING MIS 1373...

Page 14: ...delay On a call for heating circuit R W1 make at the thermostat pulling in heat contact for the strip heat and blower operation On a call for second stage heat R W2 makes bringing on second heat cont...

Page 15: ...tables can be found later in the manual covering all models It is imperative to match the correct pressure table to the unit by model number ADJUSTMENTS Adjustable Delay on Make and Delay on Break Ti...

Page 16: ...eps to reinstall REFRIGERANT CHARGE The correct system R 22 charge is shown on the unit rating plate Optimum unit performance will occur with a refrigerant charge resulting in a suction line temperatu...

Page 17: ...u t e R e r u t a r e p m e T e r u s s e r P 5 7 0 8 5 8 0 9 5 9 0 0 1 5 0 1 0 1 1 5 1 1 1 8 1 A W B D g e d 5 7 B W g e d 2 6 e d i S w o L e d i S h g i H 1 7 4 9 1 3 7 8 0 2 5 7 3 2 2 7 7 8 3 2 9...

Page 18: ...F c i r t e m o r a B X X X 2 D A F M r e p m a D r i A h s e r F d e z i r o t o M X X X 2 V R C t s u a h x E h t i w r o t a l i t n e V l a i c r e m m o C X X X 2 M F I E t s u a h x E h t i w r...

Reviews: