Manual 2100-742A
Page
39 of 54
TABLE 10A
Cooling Pressure – Standard Airflow
Air Temperature Entering Outdoor Coil °F
Low side pressure ± 4 PSIG
High side pressure ± 10 PSIG
Tables are based upon rated CFM (airflow) across the evaporator coil. If there is any doubt as to correct operating charge
being in the system, the charge should be removed and system evacuated and recharged to serial plate charge weight.
NOTE:
Pressure table based on high speed condenser fan operation. If condensing pressures appear elevated check
condenser fan wiring. See
Condenser Fan Operation
on page 27.
* Operating at these conditions would be outside the compressor operating envelope and is not recommended.
TABLE 10B
Heating Pressure – Standard Airflow
Air Temperature Entering Outdoor Coil °F
Model Indoor
Heating
0
5
10
15
17
20
25
30
35
40
45
47
50
55
60
65
Q24H4
70
Suction Pressure
Head Pressure
43
270
48
275
53
280
59
286
61
288
65
292
72
299
78
306
86
314
93
323
101
331
104
335
109
341
118
351
127
361
136
373
Q30H4
70
Suction Pressure
Head Pressure
33
230
39
247
45
262
52
277
54
283
58
291
65
305
73
317
80
329
88
339
96
350
99
353
104
359
112
367
121
375
130
381
Q36H4
70
Suction Pressure
Head Pressure
31
252
39
259
46
265
53
272
56
275
60
279
67
286
74
293
81
300
88
307
95
315
98
318
102
322
109
329
116
337
123
344
Model
Return Air Temp
(DB/WB)
Pressure
75
80
85
90
95
100
105
110
115
120
125
130
Q24H4
75/62
Suction Pressure
Head Pressure
122
291
125
314
128
337
130
361
133
385
135
410
137
435
139
460
141
486
143
513
145
540
146
573
80/67
Suction Pressure
Head Pressure
130
299
134
322
137
346
139
370
142
395
145
420
147
446
149
472
151
499
153
526
155
554
156
587
85/72
Suction Pressure
Head Pressure
135
309
138
333
141
358
144
383
147
409
150
435
152
462
154
489
156
516
158
544
160
573
162
608
Q30H4
75/62
Suction Pressure
Head Pressure
123
313
125
333
127
354
129
376
131
400
133
424
135
450
137
476
139
504
141
532
143
562
146
599
80/67
Suction Pressure
Head Pressure
131
321
134
342
136
363
138
386
140
410
142
435
144
461
147
488
149
517
151
546
153
577
156
615
85/72
Suction Pressure
Head Pressure
136
332
138
354
140
376
143
400
145
424
147
450
149
477
152
505
154
535
156
565
158
597
161
636
Q36H4
75/62
Suction Pressure
Head Pressure
125
332
128
355
131
378
133
403
136
428
137
455
139
482
140
510
142
539
142
568
143
599
143
637
80/67
Suction Pressure
Head Pressure
134
340
137
364
140
388
143
413
145
439
147
466
149
494
150
523
151
553
152
583
153
614
--*
85/72
Suction Pressure
Head Pressure
139
352
142
376
145
402
148
428
150
455
152
483
154
512
155
541
157
572
158
603
158
636
--*