R5906150 /02
XDL
55
1
1
Image 5-6: Left: Male hose connection, right: Female hose connection
CAUTION:
Do not interchange the different cooling circuits with each other! Otherwise the system
will fail.
CAUTION:
The minimum bend radius of the hoses is 30 centimeter.
5.4 Connecting the data cable with projector and
chillers
What has to be done?
Next to connecting the hoses, the communication port of the chillers has to be connected with each other and
with the projector.
Depending on the projector model one or two chillers are required! For the XDL-4K30 series projector one
chiller has to be installed. The XDL-4K60/75 series needs two chillers.
Required parts
•
One long (10 meter) communication cable with SUBD Male/Female 15 pins plugs.
•
One short (5 meter) communication cable with SUBD Male/Female 15 pins plugs (only if two chillers are
required).
How to connect the communication ports of the chillers with the projector?
1.
Does the system contain two chillers?
►
If yes,
connect the output port of one chiller (reference 1 Image 5-7) with the input port of the other chiller
(reference 2 Image 5-7). Use for this a short communication cable.
►
If no,
proceed with the next step.
2.
Connect the output port of the chiller (reference 3 Image 5-7) with the communication port of the projector
(reference 4 Image 5-7). Use for this a long communication cable.
Tip:
Guide the long communication cable together with the hoses.
Summary of Contents for XDL Series
Page 1: ...ENABLING BRIGHT OUTCOMES Installation Manual XDL ...
Page 8: ...R5906150 02 XDL 8 ...
Page 22: ...R5906150 02 XDL 22 Safety ...
Page 30: ...R5906150 02 XDL 30 System overview ...
Page 50: ...R5906150 02 XDL 50 Pulse Remote Control Unit ...
Page 64: ...R5906150 02 XDL 64 Physical Installation ...
Page 72: ...R5906150 02 XDL 72 Lenses Lens selection ...
Page 80: ...R5906150 02 XDL 80 Scheimpflug ...
Page 94: ...R5906150 02 XDL 94 Input Communication ...
Page 104: ...R5906150 02 XDL 104 WiFi GSM Module ...
Page 116: ...R5906150 02 XDL 116 Getting Started ...
Page 134: ...R5906150 02 XDL 134 Specifications ...
Page 138: ...R5906150 02 XDL 138 Environmental information ...
Page 139: ...139 R5906150 02 XDL Overview video timings for video interfaces C ...
Page 148: ...R5906150 02 XDL 148 Overview video timings for video interfaces ...
Page 155: ...R5906150 02 XDL 155 ...
Page 156: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906150 02 2018 11 07 ...