R5906150 /02
XDL
20
RA
TH
sw
PD
HD
DIFFUSE
s
w
RZ
s
w
s
w
PR
HD
REFLECTION
RESTRICTED
AREA
R
E
S
T
R
I
C
T
E
D
A
R
E
A
Image 1-3
RA
Restricted Access location (enclosed projection
area).
PR
Projector.
TH
Theater (observation area).
RZ
Restriction Zone.
PD
Projection Distance.
SW
Separation Width. Must be minimum 1 meter.
For this type of setup 3 different HD shall be considered:
•
HD as discussed in
“
High Brightness precautions: Hazard Distance (HD)
”
, page 17, relevant for intrabeam
exposure.
•
HD
reflection
: the distance that has to be kept restrictive related to the reflected light from the rear projection
screen.
•
HD
diffuse
: the relevant distance to be considered while observing the diffuse surface of the rear projection
screen.
As described in
“
High Brightness precautions: Hazard Distance (HD)
, page 17, it is mandatory to create a
restricted zone within the beam areas closer than any HD. In the enclosed projection area the combination of
two restricted zones are relevant: The restricted zone of the projected beam toward the screen; taking into
account 1 meter Separation Width (SW) from the beam onward. Combined with the restricted zone related to
the rear reflection from the screen (HD
reflection
); also taking into account a 1 meter lateral separation.
The HD
reflection
distance equals 25% of the difference between the determined HD distance and the projection
distance to the rear projection screen. To determine the HD distance for the used lens and projector model see
graphs in chapter
HD in function of modifying optics
”
, page 21.
HD
reflection
= 25% (HD – PD)
The light emitted from the screen within the observation shall never exceed the RG2 exposure limit,
determined at 10 cm. The HD
diffuse
can be neglected if the measured light at the screen surface is below 5000
cd/m² or 15000 LUX.
Summary of Contents for XDL Series
Page 1: ...ENABLING BRIGHT OUTCOMES Installation Manual XDL ...
Page 8: ...R5906150 02 XDL 8 ...
Page 22: ...R5906150 02 XDL 22 Safety ...
Page 30: ...R5906150 02 XDL 30 System overview ...
Page 50: ...R5906150 02 XDL 50 Pulse Remote Control Unit ...
Page 64: ...R5906150 02 XDL 64 Physical Installation ...
Page 72: ...R5906150 02 XDL 72 Lenses Lens selection ...
Page 80: ...R5906150 02 XDL 80 Scheimpflug ...
Page 94: ...R5906150 02 XDL 94 Input Communication ...
Page 104: ...R5906150 02 XDL 104 WiFi GSM Module ...
Page 116: ...R5906150 02 XDL 116 Getting Started ...
Page 134: ...R5906150 02 XDL 134 Specifications ...
Page 138: ...R5906150 02 XDL 138 Environmental information ...
Page 139: ...139 R5906150 02 XDL Overview video timings for video interfaces C ...
Page 148: ...R5906150 02 XDL 148 Overview video timings for video interfaces ...
Page 155: ...R5906150 02 XDL 155 ...
Page 156: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906150 02 2018 11 07 ...