3. Installation Guidelines
Image 3-2
Projector position
C
AUTION
:
Never use the projector when turned with the inputs downwards.
3.5 Re-adjusting the lamp position in the lamp casing
W
ARNING
:
As the projector has to be opened, this procedure has to be performed by qualified service tech-
nician.
Why
With higher run times, the light output of the lamp will decrease, which results in a lower light output on the screen. This light output
decrease can be compensated by readjusting the position of the lamp.
Preparation
1. Push on the top corners of the Front Panel untill a click is heard. (image 3-3, image 3-4)
2. Loosen the Front Panel.
The Front Panel will come to front.
3. Pull off the Front Panel from its Magnet Lock and take it off completly
4. On the side of the inputs, turn the retaining bolt a quarter counter clockwise. (image 3-5, image 3-6)
5. Flip the cover to the left side and take off. (image 3-7)