27
R5913592 /
Njord
CAUTION:
Replace with the correct battery type. Use two AA size batteries. There is a risk of
explosion if the battery is replaced with an incorrect type.
CAUTION:
Replace the battery as explained above. There is a risk of explosion if the battery is
incorrectly installed.
3.2 Remote control, protocol setup
About the used protocol
The protocol is the code send out by the remote control when a button is pressed. Depending on this code, the
projector can decode the signals. The remote control can be used with two different protocols: RC5 and NEC.
Depending on the projector to control the remote control can be switched between these protocols.
Which protocol to use
•
The
NEC
protocol has to be used for Barco projectors based on the Pulse platform: F70, F80, F90, HDX
4K, UDX, UDM, XDL, etc.
•
The
RC5
protocol has to be used all legacy Barco projectors: HDQ 2k40, HDF, HDX W, etc.
How to set
1.
Remove the cover. For more info on how to remove, see
“
Remote control, battery installation
, page 26.
2.
Place the switch in the desired position.
Image 3
–
4
Remarks when using the RC5 protocol
Due to new or updated functionality not all buttons of the Pulse RCU are one-to-one compatible with the
legacy Barco RCU and projectors. Take the following limitations into account:
•
Buttons
Shutter open
and
Shutter close
emit the same code when in RC5 mode. This because the
legacy RCU
’
s only had 1 button for Shutter functionality.
•
Buttons
Power on
and
Power off
emit the same code when in RC5 mode. This because the legacy RCU
’
s
only had 1 button for Power functionality.
•
The
RGB filter
button is not supported.
•
The
Input selection
button is not supported.
•
The
Default value
button is not supported.
•
The
Macro
button is not supported.
3.3 Remote control, on/off button
Purpose of the remote control on/off button
The Pulse remote control unit has at the front side an on/off switch (reference 1 Image 3
5). Switching off the
remote control prevents that unwanted commands are send due to an accidental key press. Furthermore,
switching the RCU off will extend the battery life time of the remote control.
Summary of Contents for Njord
Page 1: ...ENABLING BRIGHT OUTCOMES User Manual Njord...
Page 16: ...R5913592 Njord 16 Safety...
Page 24: ...R5913592 Njord 24 Getting Started...
Page 58: ...R5913592 Njord 58 GUI Status menu...
Page 59: ...59 R5913592 Njord Product maintenance 8...
Page 61: ...61 R5913592 Njord Risk group 3 Safety 9...
Page 70: ...R5913592 Njord 70 Index...
Page 71: ......