background image

K5902132 (451920612534) /03

MUIP-2112

24

Importers contact information

To find your local importer, contact one of Barco

s regional offices via the contact information provided on our

website (

www.barco.com

).

FCC class B

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This device generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If
this device does cause harmful interference to radio or television reception, which can be determined by
turning the device off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the device and receiver.

Connect the device into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.

FCC responsible

: Barco Inc., 3059 Premiere Parkway Suite 400, 30097 Duluth GA, United States, Tel: +1

678 475 8000

Canadian notice

CAN ICES-3 (B)/NMB-3(B)

4.5 EMC notice

General information

This device is suitable for use in healthcare facility environments.

With the installation of the device, use only the delivered external cables and power supply or a spare part
provided by the legal manufacturer. Using another can result in a decrease of the immunity level of the device.

WARNING:

Use of this equipment adjacent to or stacked with other equipment should be avoided

because it could result in improper operation. If such use is necessary, this equipment and the other
equipment should be observed to verify that they are operating normally.

WARNING:

Use of accessories, transducers and cables other than those specified or provided by

the manufacturer of this equipment could result in increased electromagnetic emissions or
decreased electromagnetic immunity of this equipment and result in improper operation.

WARNING:

Portable RF communications equipment (including peripherals such as antenna cables

and external antennas) should be used no closer than 30 cm (12 inches) to any part of the MUIP-
2112, including cables specified by the manufacturer. Otherwise, degradation of the performance of
this equipment could result.

Electromagnetic emissions

The MUIP-2112 is suitable for use in the electromagnetic environment specified below. The customer or the
user of the MUIP-2112 should assure that it is used in such an environment.

Important information

Summary of Contents for MUIP-2112

Page 1: ...ENABLING BRIGHT OUTCOMES User Guide 12 5 LCD User Interface MUIP 2112...

Page 2: ...Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com...

Page 3: ...support installation optional 12 3 Maintenance 15 3 1 Scheduled maintenance 16 3 2 Cleaning 16 4 Important information 17 4 1 Safety information 18 4 2 Environmental information 21 4 3 Biological haz...

Page 4: ...K5902132 451920612534 03 MUIP 2112 4...

Page 5: ...battery capacity could maintain the unit to work for a time of about one hour maximum In the normal application of MUIP 2112 installed in a system on a VESA arm or a desktop support with power supply...

Page 6: ...pending on model Two mains power cords EU and US versions depending on model 1 x user guide Keep your original packaging It is designed for this display and is the ideal protection during transport an...

Page 7: ...Jack 5 Audio Line Output stereo jack 6 Video Output mini DP interface for connecting an external DP or HDMI monitor 7 1 x USB 2 0 port Type A connector 8 1 x USB 3 0 port Type A connector 9 Gigabit E...

Page 8: ...K5902132 451920612534 03 MUIP 2112 8 Welcome...

Page 9: ...pter in this user guide WARNING Sufficient expertise is required to install this equipment All devices and complete setup must be tested before taking into operation CAUTION When the display is assemb...

Page 10: ...cover first route the cables as described in Cable routing page 11 Install the rear cover and follow the above steps in reverse order Power and LAN connection The MUIP 2112 Computing Touch Screen Mod...

Page 11: ...rsion only 1 Connect the USB 3 0 connector to the USB 3 0 input Image 2 4 2 2 Cable routing Open rear cover version The cables can be routed in two different ways 1 Route the cables straight downwards...

Page 12: ...th enclosed by the strain relief cable which is routed through the square hole in the closed rear cover no specific routing is needed Image 2 7 2 3 Desktop support installation optional Orientation A...

Page 13: ...112 Image 2 8 Installation 1 Place the desktop support in the desired orientation 2 Install the MUIP 2112 on the desktop support in landscape orientation 3 Install and tighten the four VESA 75 mm moun...

Page 14: ...K5902132 451920612534 03 MUIP 2112 14 Image 2 10 Installation...

Page 15: ...15 K5902132 451920612534 03 MUIP 2112 Maintenance 3...

Page 16: ...eaning cloth To clean the display Clean the display using a sponge cleaning cloth or soft tissue lightly moistened with a recognized cleaning product for medical equipment Read and follow all label in...

Page 17: ...17 K5902132 451920612534 03 MUIP 2112 Important information 4...

Page 18: ...used with life support equipment The user should not touch the signal input ports SIP signal output ports SOP and the patient at the same time The rear cover must be kept closed and screwed Mission cr...

Page 19: ...aundry tub or in a wet basement The equipment is IPx3 compliant The power supply is IPx0 Moisture condensation Do not use the equipment under rapidly changing temperature and humidity conditions or av...

Page 20: ...t the equipment hold it firmly in both hands If you drop the equipment you may be injured or the equipment may be damaged When you transport the equipment for repair or shipment use the original cardb...

Page 21: ...patients The MUIP 2112 has no essential performances and the provided Windows OS is not a class A software CAUTION The enclosure has to be checked upon collision damage refer to qualified service per...

Page 22: ...o o o o Fan o o o o o o Paper Manuals o o o o o o CD manual o o o o o o SJ T 11364 This table is prepared in accordance with the provisions of SJ T 11364 o GB T 26572 o Indicates that this toxic or h...

Page 23: ...edition of the ANSI AAMI ST35 standard on each single failed Product that is returned for servicing repair reworking or failure investigation to Seller or to the Authorized Service Provider At least...

Page 24: ...chnician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC responsible Barco Inc 3059 Premie...

Page 25: ...ifferent from that to which the receiver is connected Consult the dealer or an experienced technician for help Electromagnetic immunity The MUIP 2112 is tested to be used in the electromagnetic enviro...

Page 26: ...commercial or hospital environment Conducted RF IEC 61000 4 6 3 Vrms 6 Vrms in ISM bands 150 kHz to 80 MHz 3 Vrms 6 Vrms in ISM bands Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 7 GHz 10 V m Immunity...

Page 27: ...57 Indicates the device is approved according to the UL Recognition regulations E346057 MEDICAL GENERAL MEDICAL EQUIPMENT AS TO ELECTRICAL SHOCK FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH ANS...

Page 28: ...ed according to the INMETRO regulations Indicates the USB connectors on the device Indicates the DisplayPort connectors on the device yy xx Indicates the temperature limitations3 for the device to saf...

Page 29: ...that it should be carried with two persons Indicates that the box should not be cut with a knife a cutter or any other sharp object 20 C 60 C xx yy Indicates the temperature limits4 to which the devic...

Page 30: ...ssor SoC Intel Celeron N2930 Quad Core 1 83GHz 2MB Cache BIOS INSYDE Operating System Microsoft Windows 7 Embedded Windows 10 ioT Networking Built in Gigabit Ethernet LAN interfaces 2 ports Memory 4 G...

Page 31: ...0601 1 14 Medical Electrical Equipment Part 1 General Requirements for Basic Safety and Essential Performance Harmonized with Ed 3 1 IEC 60601 1 2 2014 EN 60601 1 2 2015 EN 55011 CISPR11 Class B FCC C...

Page 32: ...sktop support Dimensions W x H x D 312 x 200 x 37 mm Certifications compliance China CCC Europe CE ITE DEMKO US and Canada UL FCC ICES 003 Standards IEC 60601 1 2012 Edition 3 1 Medical electrical equ...

Page 33: ...20612534 03 MUIP 2112 Image 4 1 Code number 12NC or K code Model No Serial number 72yyww000000 72 Original code FIMI yy Year ww Week 01 to 52 Manufacturer Date 000000 6 digits progressive number Impor...

Page 34: ...K5902132 451920612534 03 MUIP 2112 34 Important information...

Page 35: ......

Page 36: ...Barco NV Beneluxpark 21 8500 Kortrijk Belgium Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com K5902132 451920612534 03 2020 11 18...

Reviews: