Page 1: ...ENABLING BRIGHT OUTCOMES MDSC 2324 LED MDSC 2324 DDI MDSC 2324 MNA User Guide MDSC 2324 ...

Page 2: ...Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com ...

Page 3: ...ype A connector 18 2 4 7 Mini USB connector 18 2 4 8 DisplayPort connector 18 2 4 9 S Video and S Video out connector 19 3 Display installation 21 3 1 VESA mount installation 22 3 2 Cover removal 22 3 3 Video input connection 23 3 3 1 MDSC 2324 LED version 23 3 3 2 MDSC 2324 DDI version 23 3 3 3 MDSC 2324 MNA version 24 3 4 Video output connection 25 3 4 1 MDSC 2324 LED version 25 3 4 2 MDSC 2324 ...

Page 4: ...tion 41 5 1 OSD picture menu 42 5 1 1 Profile 42 5 1 2 Brightness 42 5 1 3 Contrast 43 5 1 4 Saturation 43 5 1 5 Color temperature 43 5 1 6 Gamma 44 5 1 7 Sharpness 44 5 2 Picture Advanced menu 44 5 2 1 Black Level 44 5 2 2 Smart Video 45 5 2 3 Image Position 45 5 2 4 Auto Adjustment 45 5 2 5 Phase 46 5 2 6 Clock Line 46 5 3 Display Format menu 46 5 3 1 Main Source Primary Source 47 5 3 2 Componen...

Page 5: ...ard backlight 57 5 5 7 Power Saving 57 6 Important information 59 6 1 Safety information 60 6 2 Environmental information 62 6 3 Biological hazard and returns 64 6 4 Regulatory compliance information 64 6 5 EMC notice 65 6 6 Cleaning and disinfection 68 6 7 Explanation of symbols 68 6 8 Legal disclaimer 71 6 9 Technical specifications 72 6 10 Open source license information 76 ...

Page 6: ...K5903252 451920612633 02 MDSC 2324 6 ...

Page 7: ...7 K5903252 451920612633 02 MDSC 2324 Welcome 1 ...

Page 8: ... cables for a clutter free set up Its lightweight design allows easy mounting on surgical booms and spring arms Available in different models this surgical display also features a host of connectivity options and remote control Ease of use Barco s MDSC 2324 allows easy cleaning and complete disinfection thanks to its smooth surface sealed housing and protective screen cover The fanless design avoi...

Page 9: ...manual provides support to the user during the installation set up and utilization of the MDSC 2324 display Depending on the specific version that has been purchased some of the features and options described in this document may not apply to the display in user s hands Welcome ...

Page 10: ...K5903252 451920612633 02 MDSC 2324 10 Welcome ...

Page 11: ...11 K5903252 451920612633 02 MDSC 2324 Product overview 2 ...

Page 12: ...efault only the stand by key is visible When you touch any of the keys shortly the front illumination of all other keys is switched on for a few seconds When you touch any of these other keys again while the illumination is on the function of the key is executed If no further action is taken within the time out the front key illumination is switched off again The auto dim function of the front key...

Page 13: ...mpartment cover 5 Connector compartment cover fixation screw 2 3 Connector view 2 3 1 MDSC 2324 LED version Overview 10 11 12 13 14 15 16 17 5 6 7 8 9 4 3 2 1 Image 2 3 1 SDI 1 out 2 SDI 1 3 Input power connector 4 Potential Equalization pin POAG 5 RS232 6 Sync 7 CVBS 8 CVBS out 9 S Video out 10 DVI out 11 DVI 1 DVI I digital analog with HDCP 12 DisplayPort VESA std 1 1a Product overview ...

Page 14: ...ut 3 SDI 2 4 SDI 1 out 5 SDI 1 6 Input power connector 7 Potential Equalization pin POAG 8 RS232 9 Sync 10 CVBS 11 CVBS out 12 S Video out 13 DVI out 14 DVI 1 DVI I digital analog with HDCP 15 DisplayPort VESA std 1 1a 16 R Pr 17 G Y SOG 18 B 19 S Video 20 Service 2 3 3 MDSC 2324 MNA version Overview 1 3 4 6 5 2 9 14 15 16 17 18 19 20 10 7 11 12 13 21 8 Image 2 5 1 Optical 10Gb Ethernet SFP interf...

Page 15: ...gital analog with HDCP 16 DisplayPort VESA std 1 1a 17 R Pr 18 G Y SOG 19 B 20 S Video 21 Service Nexxis OR functionality for more detailed information on Barco s Nexxis integrated OR solution please refer to the dedicated user guides Please visit my barco com to obtain these user guides 2 4 Connector pin assignments 2 4 1 Input power connector Overview Image 2 6 1 GND 2 Not connected 3 24 VDC 4 G...

Page 16: ... D S 19 GND data 0 shield 20 Not connected 21 Not connected 22 GND clock shield 23 CK_Rx T M D S 24 CK_Rx T M D S 25 C1 Analog Red 26 C2 Analog Green 27 C3 Analog Blue 28 C4 Analog horizontal sync 29 C5 Analog GND return analog R G B 5 VDC output selectable on either pin 14 or 16 via the OSD menu 5V 10 500mA max PC analog VGA input source can be connected to the DVI I input connector using a DVI I...

Page 17: ...M D S 19 GND data 0 shield 20 Not connected 21 Not connected 22 GND clock shield 23 CK_Rx T M D S 24 CK_Rx T M D S 5 VDC output selectable on either pin 14 or 16 via the OSD menu 5V 10 500mA max 2 4 4 DVI out connector DVI D DVI D The DVI out connector is also a DVI D connector type see previous paragraph for more details 2 4 5 RS232 connector Overview Image 2 9 1 Not connected 2 Rx driven by host...

Page 18: ...ata 3 Data 4 Not connected 5 GND 2 4 8 DisplayPort connector Overview sink side pin out 19 17 15 13 11 9 7 5 3 1 20 18 16 14 12 10 8 6 4 2 Image 2 12 1 ML_Lane 3 n 2 GND 3 ML_Lane 3 p 4 ML_Lane 2 n 5 GND 6 ML_Lane 2 p 7 ML_Lane 1 n 8 GND 9 ML_Lane 1 p 10 ML_Lane 0 n 11 GND 12 ML_Lane 0 p 13 CONFIG1 14 CONFIG2 15 AUX CH p 16 GND 17 AUX CH n 18 Hot Plug 19 Return Product overview ...

Page 19: ...252 451920612633 02 MDSC 2324 19 20 DP_PWR 3 3 VDC 500 mA max 2 4 9 S Video and S Video out connector Overview Image 2 13 1 Ground Y 2 Ground C 3 Luminance Y 4 Chroma C 5 SG Shielded Ground Product overview ...

Page 20: ...K5903252 451920612633 02 MDSC 2324 20 Product overview ...

Page 21: ...21 K5903252 451920612633 02 MDSC 2324 Display installation 3 ...

Page 22: ...ttach the arm stand firmly to the panel using the included 4 hexagonal screws M4 x 25 mm and the dented washers Use the included Allen key to fix the screws Image 3 1 CAUTION The 4 screws included with this display M4 x 25 mm can be used for an external VESA arm interface with a thickness of up to 5 mm If due to the thickness of the external VESA arm interface V the length of the provided screws L...

Page 23: ...hapter describes how to connect the different video input types for each version of the MDSC 2324 3 3 1 MDSC 2324 LED version To connect the video inputs 1 Connect one or more of the available video source s to the corresponding video inputs using the appropriate video cable s DVI or VGA 4 DisplayPort 5 SDI 1 R G B S 6 7 8 2 R G B SOG 6 7 8 Y Pb Pr 7 8 6 CVBS 3 S Video 9 PC analog VGA input source...

Page 24: ... 6 1 8 9 10 11 3 2 4 5 Image 3 4 3 3 3 MDSC 2324 MNA version To connect the video inputs 1 Connect one or more of the available video source s to the corresponding video inputs using the appropriate video cable s Nexxis 3 DVI or VGA 4 DisplayPort 5 R G B S 6 7 8 1 Y Pb Pr 7 8 6 CVBS 2 S Video 9 PC analog VGA input source can be connected to the DVI I input connector using a DVI I to VGA adapter Th...

Page 25: ...nnected with the MDSC 2324 to another display projector video recorder This chapter describes how to make use of the video output connections available for each version of the MDSC 2324 3 4 1 MDSC 2324 LED version To connect the video outputs 1 Connect one or more of the available video sink s to the corresponding video outputs using the appropriate video cable s SDI 1 CVBS 2 S Video 3 DVI 4 to be...

Page 26: ... video cable s SDI 1 2 SDI 2 1 CVBS 3 S Video 4 DVI 1 or DVI 2 5 to be configured in OSD menu 5 4 3 2 1 Image 3 7 3 4 3 MDSC 2324 MNA version To connect the video outputs 1 Connect one or more of the available video sink s to the corresponding video outputs using the appropriate video cable s CVBS 1 S Video 2 DVI 3 to be configured in OSD menu Nexxis 3 to be configured in OSD menu Display installa...

Page 27: ...isit www barco com to obtain these user guides Nexxis OR is only available on the MDSC 2324 MNA version 3 6 Power supply connection To connect the power supply 1 Connect the supplied external DC power supply unit to the 24 VDC power input of your display 2 Plug the other end of the external DC power supply into a grounded power outlet by means of the proper power cord delivered in the packaging Im...

Page 28: ...her devices is required then connect the potential equalization pin POAG DIN42801 to the potential equalization terminal of the equipment Image 3 11 3 7 Cable routing To route the cables 1 For displays mounted to a VESA arm with internal cable routing provisions route all cables through the cable routing channel then reinstall the connector compartment cover 8a Image 3 12 or For all other mounting...

Page 29: ...K5903252 451920612633 02 MDSC 2324 29 8b Image 3 13 WARNING When the display is assembled in the medical system take care of the fixation of all cables to avoid unwanted detachment Display installation ...

Page 30: ...K5903252 451920612633 02 MDSC 2324 30 Display installation ...

Page 31: ...31 K5903252 451920612633 02 MDSC 2324 Daily operation 4 ...

Page 32: ...linked to the on off status of the keyboard backlight the backlight is always on in this mode except when in Power Save of Soft Off Therefore the keyboard lock status is being signaled by a slow blinking of the keyboard backlight between on and off at a rate of one cycle per second The Keyboard will automatically lock after 10 minutes Keyboard backlight On with touch Factory default Keyboard backl...

Page 33: ...is hard OFF the switch of the power supply is OFF Led is fading between on and off the status of the unit is soft OFF when pushing the standby button the unit is on or off Led is full orange the unit is in power save mode no signal power save mode enabled Led is blinking green orange the unit is in searching mode looking for a signal Led is full green the unit has an image on the screen 4 5 OSD me...

Page 34: ...the desired Menu page is highlighted press the key to select the top menu item that will be highlighted Use the or keys to move to other Menu Items then press the key to select it If the selected menu item is controlled by a slider use the or keys to adjust the item value then press the key to confirm If the selected menu item is a multiple choices menu use the or keys to select the desired option...

Page 35: ... to scroll through all the possible input signals to select the main input source When the extended keyboard functionality is enabled the shortkey functions will no longer be available and will be replaced by the corresponding extended keyboard functions described in the next chapter 4 7 2 Multi image configuration To quickly select the multi image configuration 1 Use the PiP selection key to scro...

Page 36: ...ed through dedicated OSD menu function by simply pressing one of the first 3 keys on the left the user is presented with a list of new selections displayed on screen the new choices can be selected by using each of the key just below the OSD text If two options are available for one key the first key press will select the upper option a second press selects the lower option The different available...

Page 37: ...urrent selection is marked in red 3 Press the stand by key to confirm your choice and exit the main source quick selection menu Main source VGA DP R G B Y Pb Pr S Video CVBS DVI SDI Nexxis 2nd Source E X I T Image 4 6 4 8 2 Second source selection To quickly select the second source 1 While no OSD Menu is on the screen press the Input selection key to bring up the main source quick selection menu ...

Page 38: ...on menu Multi image config Native Aspect Fill Small Large None E X I T Image 4 8 4 8 4 Common Functions Transfer function selection To quickly select the transfer function 1 While no OSD Menu is on the screen press the Image zoom key to bring up the common functions quick selection menu 2 Toggle the available transfer function settings by pressing the key corresponding to the desired option The cu...

Page 39: ...Functions Zoom factor selection To quickly select the zoom factor 1 While no OSD Menu is on the screen press the Image zoom key to bring up the common functions quick selection menu 2 Toggle the available zoom factors by repeatedly pressing the key until the desired zoom factor is shown 3 Press the stand by key to confirm your choice and exit the common functions quick selection menu Common Functi...

Page 40: ...SC 2324 40 After pressing the fourth key if the sequence is correct the main OSD menu is activated To unlock the keyboard permanently the specific OSD function is required Keyboard lock Sequence 5 6 6 3 Image 4 12 Daily operation ...

Page 41: ...41 K5903252 451920612633 02 MDSC 2324 Advanced operation 5 ...

Page 42: ...nd can always be recalled through the recall profile menu item The available profiles for your display are Factory X Ray User 1 User 2 User 3 To select a profile 1 Bring up the OSD main menu 2 Navigate to the Picture menu 3 Enter the Profile submenu 4 Select one of the available profiles and confirm 5 1 2 Brightness To adjust the brightness level 1 Bring up the OSD main menu 2 Navigate to the Pict...

Page 43: ...bration White point The White Color points associated with the Color Temperature 5600K 6500K 7600K or 9300K are factory calibrated with a consequent reduction of the maximum luminance compared to Native Color Temperature Factory calibration Color space When ITU 709 is selected the White Color point and the RGB color primaries are adjusted according to the target HDTV sRGB color space defined in th...

Page 44: ...enu 3 Enter the Gamma submenu 4 Select one of the available gamma presets and confirm 5 1 7 Sharpness To adjust the sharpness level 1 Bring up the OSD main menu 2 Navigate to the Picture menu 3 Enter the Sharpness submenu The command bar Sharpness is highlighted 4 Set the sharpness level as desired and confirm 5 2 Picture Advanced menu Overview Black Level Smart Video Image Position Auto Adjustmen...

Page 45: ... is between 1 to 2 Video Frame periods excluding S Video CVBS analog and SFP optical MNA versions inputs which have an additional delay of maximum 1 Video Frame period To select a Smart Video preset 1 Bring up the OSD main menu 2 Navigate to the Picture advanced menu 3 Enter the Smart Video submenu 4 Select one of the available Smart Video presets and confirm 5 2 3 Image Position This menu item is...

Page 46: ...g up the OSD main menu 2 Navigate to the Picture advanced menu 3 Enter the Phase submenu The command bar Phase is highlighted 4 Set the phase as desired and confirm 5 2 6 Clock Line This menu item is only available when VGA input is connected About clock line If the result of the Auto Adjustment procedure described above isn t satisfactory the Clock Line can be manually adjusted by following this ...

Page 47: ...d keyboard functionality To select the main source 1 Bring up the OSD main menu 2 Navigate to the Display Format menu 3 Enter the Main Source submenu 4 Select one of the available main source and confirm Note If you selected the Auto Search preset the display will automatically detect the connected signal 5 3 2 Component Mode About component modes The available component modes for your display are...

Page 48: ...on in image aspect ratio Native input pixel to LCD pixel mapping no scaling In Aspect and Native the image may be displayed with black bars on top bottom or left right The image size can also be selected via the extended keyboard functionality To select the image size 1 Bring up the OSD main menu 2 Navigate to the Display Format menu 3 Enter the Image Size submenu 4 Select one of the available ima...

Page 49: ...s for your display are Auto Search Composite S Video Component PC Analog DVI 1 DVI 2 SDI 1 SDI 2 Nexxis DisplayPort The 2nd picture source can also be selected via the extended keyboard functionality Independent Transfer Function Gamma and Color temperature for the 2nd Picture Souce are always set to Native and 6500K independently from the Transfer Function applied to the Main Picture Source For a...

Page 50: ...ture Swap submenu 4 Select the desired setting and confirm 5 4 Configuration menu Overview Information Language Failover mode Extended keyboard OSD setting Recall Profile Save Profile 5 4 1 Information About information The available information items for your display are Model commercial type identification Operating Hours backlight operation hours Firmware Release firmware identification Hardwar...

Page 51: ...d Picture Source is changed A warning message Failover off appears on the screen for a few seconds Returning to the original Main Backup combination will automatically re enable the Failover feature For the MNA version only Failover mode will be activated up to 12 seconds after the Nexxis signal becomes unavailable delay required to allow a Nexxis layout change To enable disable failover mode 1 Br...

Page 52: ...ubmenu 4 Select OSD Hor Pos The command bar OSD Hor Pos is highlighted 5 Set the OSD horizontal position as desired and confirm 5 4 5 2 OSD Vertical Position To adjust the OSD vertical position 1 Bring up the OSD main menu 2 Navigate to the Configuration menu 3 Enter the OSD setting submenu 4 Select OSD Ver Pos The command bar OSD Ver Pos is highlighted 5 Set the OSD vertical position as desired a...

Page 53: ...irm 5 4 7 Save Profile About saving profiles The user can modify the default video parameters associated to each profile and save the new parameter settings under the User 1 User 2 or User 3 profile The Factory and X Ray profiles can be modified but the factory default can t be overwritten and can always be recalled through the recall profile menu item The available profiles to save in your displa...

Page 54: ...on Pin 14 5V on Pin 16 To select the power on DVI 2 1 Bring up the OSD main menu 2 Navigate to the System menu 3 Enter the Power on DVI 2 submenu 4 Select one of the available options and confirm 5 5 3 DVI Output About DVI output This setting allows you to select which digital input to replicate on the DVI out connector Depending on the display version and the main and second picture selection the...

Page 55: ...s Yes Yes Nexxis Yes No Yes Other Yes Yes Yes Nexxis DVI Yes No Yes Nexxis Yes Yes Yes Other Yes Yes Yes Other DVI Yes Yes Yes Nexxis Yes Yes Yes Other Yes Yes Yes To select the DVI output 1 Bring up the OSD main menu 2 Navigate to the System menu 3 Enter the DVI output submenu 4 Select one of the available options and confirm 5 5 4 DVI Output About DVI output This setting allows you to select whi...

Page 56: ... Yes DVI 2 DVI 1 No Yes Yes DVI 2 No Yes Yes SDI 1 No Yes Yes SDI 2 No Yes Yes Other No Yes Yes SDI 1 DVI 1 Yes No Yes DVI 2 No Yes Yes SDI 1 Yes Yes Yes SDI 2 No No Yes Other Yes Yes Yes SDI 2 DVI 1 Yes No Yes DVI 2 No Yes Yes SDI 1 No No Yes SDI 2 Yes Yes Yes Other Yes Yes Yes Other DVI 1 Yes Yes Yes DVI 2 No Yes Yes SDI 1 Yes Yes Yes SDI 2 Yes Yes Yes Other Yes Yes Yes MDSC 2324 MNA version Mai...

Page 57: ...sired and confirm 5 5 6 Keyboard backlight About the keyboard backlight By default after lighting up the keyboard backlight will dim again if no further actions are taken within the following 5 seconds However this behavior can be changed so that the keyboard backlight is always on To adjust the keyboard backlight 1 Bring up the OSD main menu 2 Navigate to the System menu 3 Enter the Keyboard Back...

Page 58: ...K5903252 451920612633 02 MDSC 2324 58 2 Navigate to the System menu 3 Enter the Power Saving submenu 4 Enable Disable power saving as desired and confirm Advanced operation ...

Page 59: ...59 K5903252 451920612633 02 MDSC 2324 Important information 6 ...

Page 60: ...quipment Equipment primarily for use in a health care facility that is intended for use where contact with a patient is unlikely no applied part The equipment shall not be used with life support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patient at the same time Mission critical applications We strongly recommend there is a repl...

Page 61: ... position for best resistance to fluids Moisture condensation Do not use monitor under rapid temperature and humidity change condition or avoid cold air from air conditioning outlet directly Moisture may condense on the surface or inside of the unit or create a mist residue inside the protection plate this is not a malfunction of the product itself although it may cause damage to the monitor If co...

Page 62: ...nitor is not intended to be sterilized The monitor has not applied parts but the front side of the LCD panel and the plastic enclosure have been treated as applied part because considered accidentally touchable by the patient for a time 1 minute National Scandinavian Deviations for CL 1 7 2 Finland Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan Norway Apparatet må tilkop...

Page 63: ...项目 名称 Component name 有毒有害物质或元素 Hazardous substances and elements 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr6 多溴联苯 PBB 多溴二苯醚 PBDE 印制电路配件 Printed Circuit Assemblies X O O O O O 液晶面板 LCD panel X O O O O O 外接电 线 缆 External Cables X O O O O O 內部线路 Internal wiring O O O O O O 金属外壳 Metal enclosure O O O O O O 塑胶外壳 Plastic enclosure O O O O O O 散热片 器 Heatsinks O O O O O O 风扇 Fan O O O O O O 电源供应器 Power Supply Unit X O O O O O...

Page 64: ...ent spreading of infections Therefore use of this device in such environments is at the exclusive risk of Customer In case this device is used where potential biological contamination cannot be excluded Customer shall implement the decontamination process as defined in the latest edition of the ANSI AAMI ST35 standard on each single failed Product that is returned for servicing repair reworking or...

Page 65: ...reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in w...

Page 66: ...DSC 2324 is intended for use in the electromagnetic environment IEC 60601 1 2 4th edition specified below The customer or the user of the MDSC 2324 should assure that it is used in such an environment Immunity test IEC 60601 1 2 4th edition 2014 Test levels Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 8kV contact 15kV air 8kV contact 15kV air Floo...

Page 67: ...watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey 2 should be less than the compliance level in each frequency range 3 Interference may occur in the vicinity of equipment marked with symbol At 80 MHz and 800 MHz the higher frequency range applies Impor...

Page 68: ...ituations Electromagnetic propagation is affected by absorption and reflection form structures object and people 6 6 Cleaning and disinfection Instructions Be sure to unplug the power cord from the mains when cleaning your LCD monitor Take care not to scratch the front surface with any hard or abrasive material Dust finger marks grease etc can be removed with a soft damp cloth a small amount of mi...

Page 69: ...ice is approved according to the VCCI regulations Indicates the device is approved according to the KC regulations Indicates the device is approved according to the BSMI regulations Indicates the device is approved according to the PSE regulations Indicates the device is approved according to the RCM regulations Indicates the device is approved according to the EAC regulations Caution Federal law ...

Page 70: ...aution Consult the operating instructions Indicates this device must not be thrown in the trash but must be recycled according to the European WEEE Waste Electrical and Electronic Equipment directive Indicates Direct Current DC Indicates Alternating Current AC Stand by Equipotentiality or Protective earth ground Symbols on the box On the box of the device you may find the following symbols nonrest...

Page 71: ...mer Disclaimer notice Although every attempt has been made to achieve technical accuracy in this document we assume no responsibility for errors that may be found Our goal is to provide you with the most accurate and usable documentation possible if you discover errors please let us know Barco software products are the property of Barco They are distributed under copyright by Barco NV or Barco Inc...

Page 72: ...t signals DVI CVBS S video SDI HD SDI 3GSDI Power source requirements for external power supply nominal 100 250 VAC Power source requirements for display power input LED and DDI version 24 VDC 2 3 A max MNA version 24 VDC 3 2 A max Power consumption LED and DDI version 55 W max MNA version 75 W max Power save mode Yes Dot clock 165 MHz max DVI OSD languages English French German Spanish Italian Di...

Page 73: ...24 LED and DDI version Class B RoHS compliant IP21 IP45 front side only Supplied accessories User Guide Video cable DVI Dual Link Mains cables European CEBEC KEMA USA UL CSA Chinese Z3487500 Chinese power cord L 1500 External power supply Optional accessories Barco stand K9302097A Power extension cable 10m K3495066 Power extension cable 30m K3495068 Operating temperature 10 35 C for performance 0 ...

Page 74: ... 7 Y Diag mode 7 30 DMT1075 1024 x 768 XGA 60 75 Y Y 31 DMT1085 1024 x 768 XGA 68 7 85 Y Y 32 DMT1175 1152 x 864 XGA 67 5 75 Y Y 33 DMT1260G 1280 x 1024 SXGA 64 60 Y Y 34 DMT1275G 1280 x 1024 SXGA 79 976 75 025 Y Y 35 DMT1285G 1280 x 1024 SXGA 91 1 85 Y Y 36 DMT1660 1600 x 1200 UXGA 75 60 Y Y 37 CVR1460 1400 x 1050 SXGA 64 744 59 948 Y Y 38 CVT1460 1400 x 1050 SXGA VESA 65 32 59 98 Y Y 39 CVR1660D...

Page 75: ...0 1920 x 1080 1080p 67 5 60 Y Y Timings SDI Ite m Name Pixel x Line Format Hor Fr kHz Vert Fr Hz Hor Total Vert Total SDI Ypb RGBS YPbPr 1 480i 720 x 487 NTSC 15 734 59 94 Y Y 4 576i 720 x 576 PAL I 15 625 50 Y Y 8 720p50 1280 x 720 720p 37 5 50 Y Y 9 720p59 1280 x 720 720p 44 96 59 94 Y Y 10 720p60 1280 x 720 720p 45 60 Y Y 11 1080i25 1920 x 1080 1080i 28 13 50 Y Y 12 1080i29 1920 x 1080 1080i 33...

Page 76: ...ledge living up to the conditions of each separate Open Source Software license A list of the Open Source Software components used is available in the applicable EULA through the My Barco section of the Barco website or through other online means Copyright on each Open Source Software component belongs to the respective initial copyright holder each additional contributor and or their respective a...

Page 77: ...licable Open Source Software license You are responsible for your own additions changes or modifications without any recourse or claim towards Barco whatsoever You further acknowledge that any such additions changes or modifications may impair the ability of Barco at Barco s sole discretion to continue to provide service warranties software updates fixes maintenance access or such similar abilitie...

Page 78: ...eluxpark 21 8500 Kortrijk Belgium Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com K5903252 451920612633 02 2019 03 20 Barco NV President Kennedypark 35 8500 Kortrijk Belgium ...