Overview of Commands
MDSC-1119 and MDSC-2124 _________________________________________________________________ 46
4.11.10.
CLMPV
This command turns clamp width adjust on/off for certain inputs. Clamp width is only
available with some input types see online user manual for details.
Command
CMD
5-100
RV
MM
Mm
CLMPV
•
CMD
Sets clampwidth value
Example:
CMD,CLMPV,75
Response:
75
•
RV
Reads clampwidth value
Example:
RV,CLMPV
Response:
75
•
MM
Returns: 100
Example:
MM,CLMPV
Response:
100
•
Mm
Returns: 5
Example:
Mm,CLMPV
Response:
5
4.12.
ASCII Specific Commands
4.12.1.
DPMS
This command enables and disables standby mode. Coming out of standby takes
several seconds.
Command
CMD
0/1
RV
MM
Mm
DPMS
•
CMD
Enables / disables DPMS
Example:
CMD,DPMS,1
Response:
1