![Barco MDSC-1119 Manual Download Page 24](http://html1.mh-extra.com/html/barco/mdsc-1119/mdsc-1119_manual_4068123024.webp)
Overview of Commands
MDSC-1119 and MDSC-2124 _________________________________________________________________ 24
4.6.11.
PIPN
This command allows you to change the PIP layout name for the current PIP layout.
Command
PIP Layout Name
CMD
PIP Layout Name
RV
MM
Mm
PIPN
•
CMD
Sets the PIP layout name
Example:
CMD,PIPN,PIP Name
Response:
PIP Name
•
RV
Reads the currently selected PIP layout name.
Example:
RV,PIPN
Response:
PIP Name
•
MM
Returns the maximum number of characters in the alias name.
Example:
MM,PIPN
Response:
10
•
Mm
Returns the minimum number of characters in the PIP layout.
Example:
Mm,PIPN
Response:
1
4.7.
User Profile commands
4.7.1.
PRO
This command selects a profile 0-20. Profile 0 is profile off. Profiles are only selectable
if they have been previously filled and saved (same as OSD).
Command
Profile Number
CMD
0 – 20
RV
MM
Mm
PRO
•
CMD
Selects profile returns profile number. If profile is not active error
9 is returned.
Example:
CMD,PRO,3
Response:
3
•
RV
Reads the currently selected profile number
Example:
RV,PRO
Response:
3