background image

R5913897 /00

MDMX-MNA

28

Interference can be determined by turning the equipment off and on.

If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding
equipment, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna or equipment.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced technician for help.

Electromagnetic immunity

The MDMX-MNA is intended for use in the electromagnetic environment specified below. The customer or the
user of the MDMX-MNA should assure that it is used in such an environment.

Immunity test

IEC 60601 test levels

Compliance level

Electromagnetic
environment

guidance

Electrostatic discharge
(ESD)
IEC 61000-4-2

± 8 kV contact
± 2 kV, ± 4 kV, ± 8 kV, ± 15
kV air

± 8 kV contact
± 2 kV, ± 4 kV, ± 8 kV, ± 15
kV air

Floors should be wood,
concrete or ceramic tile. If
floors are covered with
synthetic material, the
relative humidity should be
at least 30%

Electrical fast transient/
burst
IEC 61000-4-4

± 2 kV for power supply
lines
± 1 kV for input/ output
lines
100 kHz repetition
frequency

± 2 kV for power supply
lines
± 1 kV for input/ output
lines
100 kHz repetition
frequency

Mains power quality
should be that of a typical
commercial or hospital
environment

Surge
IEC61000-4-5

Line to line: ± 0.5 kV, ± 1
kV
Line to ground: ± 0.5 kV, ±
1 kV, ± 2 kV

Line to line: ± 0.5 kV, ± 1
kV
Line to ground: ± 0.5 kV, ±
1 kV, ± 2 kV

Mains power quality
should be that of a typical
commercial or hospital
environment

Voltage dips, short
interruptions and voltage
variations on power supply
input lines
IEC 61000-4-11

0% residual voltage for 0.5
period at 0°, 45°, 90°,
135°, 180°, 225°, 270°
and 315°
0% residual voltage for 1
period at 0°
70% residual voltage for
25 periods at 0°
Voltage interruptions: 0%
residual voltage for 250
periods at 0°

0% residual voltage for 0.5
period at 0°, 45°, 90°,
135°, 180°, 225°, 270°
and 315°
0% residual voltage for 1
period at 0°
70% residual voltage for
25 periods at 0°
Voltage interruptions: 0%
residual voltage for 250
periods at 0°

Mains power quality
should be that of a typical
commercial or hospital
environment. If the user of
the MDMX-MNA requires
continued operation
during power mains
interruptions, it is
recommended that the
MDMX-MNA be powered
from an uninterruptible
power supply or a battery

Power frequency (50/60
Hz) magnetic field
IEC 61000-4-8

30 A/m

Not applicable

1

Power frequency
magnetic fields should be
at levels characteristic of a
typical location in a typical
commercial or hospital
environment

Conducted RF
IEC 61000-4-6

3 Vrms (6 Vrms in ISM
bands)
150 kHz to 80 MHz

3 Vrms (6 Vrms in ISM
bands)

-

Radiated RF
IEC 61000-4-3

3 V/m
80 MHz to 2.7 GHz

3 V/m

Important information

1.

MDMX-MNA doesn

t contain susceptible components to magnetic fields

Summary of Contents for MDMX-MNA

Page 1: ...ENABLING BRIGHT OUTCOMES MDMX 22400 MDMX 25500 MDMX 22449 User Guide In wall console for the digital OR MDMX MNA...

Page 2: ...Barco Visual Beijing Electronics Co Ltd Suzhou Branch Floor 4 No 179 Suhong West Road Suzhou Industrial Park 215021 Suzhou China 179 4 www barco com en support www barco com...

Page 3: ...peration 15 3 1 On switching 16 3 2 Off switching 16 3 3 Stopwatch MDMX 22400 and MDMX 22449 16 3 4 DICOM PACS images optimization 16 3 5 Nexxis WorkSpot MDMX 25500 17 4 Cleaning and disinfection 19 4...

Page 4: ...R5913897 00 MDMX MNA 4...

Page 5: ...5 R5913897 00 MDMX MNA Welcome 1...

Page 6: ...ribed subject 1 2 About the product Overview Barco s MDMX MNA is an in wall console purpose built for multi image viewing in the digital operating room The MDMX MNA is an all in one central management...

Page 7: ...7 R5913897 00 MDMX MNA Image 1 1 MDMX 22400 Option GNTB Welcome...

Page 8: ...2400 Option GNTB MDMX 25500 Option GNNB MDMX 22449 Option GNTB Housing Powder coated steel Powder coated steel Powder coated steel Housing color front Black Black Black Front keyboard module 1x option...

Page 9: ...1 4 What s in the box Overview MDMX MNA console User guide and installation manual printed in English other languages can be found on the USB stick or online USB stick containing user documentation M...

Page 10: ...R5913897 00 MDMX MNA 10 Welcome...

Page 11: ...11 R5913897 00 MDMX MNA Parts controls and connectors 2...

Page 12: ...22449 Displays the time date and stopwatch function 2 Neutrik front connection For optional mobile Nexxis device connectivity 3 Mounting for keyboard module For optional keyboard module 4 USB 2 0 por...

Page 13: ...lectric connections on the front side of the device must be covered by their respective sealing caps 2 1 1 Nexxis button Overview The Nexxis button provides a trigger signal to the embedded MNA decode...

Page 14: ...R5913897 00 MDMX MNA 14 Image 2 4 Parts controls and connectors...

Page 15: ...15 R5913897 00 MDMX MNA Daily operation 3...

Page 16: ...light of the power button for external PC turns off 3 3 Stopwatch MDMX 22400 and MDMX 22449 Using the stopwatch The stopwatch status is displayed on the SmartBar and via LED lights 1 Press the Start R...

Page 17: ...ensed feature and can be activated by purchasing the WorkSpot license Nexxis WorkSpot provides the following features a composition of up to 6 video slots control each video source separately with the...

Page 18: ...R5913897 00 MDMX MNA 18 Image 3 2 For more details on how to use Nexxis WorkSpot see https www youtube com watch v lKAGOCYleCY Daily operation...

Page 19: ...19 R5913897 00 MDMX MNA Cleaning and disinfection 4...

Page 20: ...electing an alternative cleaning disinfecting product it is recommended to always identify the active ingredients In case of doubt about a certain cleaning product use plain water Do not use any of th...

Page 21: ...21 R5913897 00 MDMX MNA Important information 5...

Page 22: ...modules These batteries should be renewed every three years by authorized service personnel only Electrical Shock or Fire Hazard To prevent electric shock or fire hazard do not remove cover parts No...

Page 23: ...uct is intended for indoor use The product is not intended to be sterilized The product has no applied parts but the front side of the product and the steel enclosure have been treated as applied part...

Page 24: ...l service For details please visit the Barco website at http www barco com AboutBarco weee Turkey RoHS compliance T rkiye Cumhuriyeti AEEE Y netmeli ine Uygundur Republic of Turkey In conformity with...

Page 25: ...the use of hazardous substances in electrical and electronic product of Chinese Mainland marked with the Environmental Friendly Use Period EFUP logo The number inside the EFUP logo that Barco uses pl...

Page 26: ...thority of the Member State in which the user and or patient is established Factory address Barco Visual Beijing Electronics Co Ltd Suzhou Branch Floor 4 No 179 Suhong West Road Suzhou Industrial Park...

Page 27: ...might not offer adequate protection to radio frequency communication services The user might need to take mitigation measures such as relocating or re orienting the equipment Electromagnetic emissions...

Page 28: ...Mains power quality should be that of a typical commercial or hospital environment Surge IEC61000 4 5 Line to line 0 5 kV 1 kV Line to ground 0 5 kV 1 kV 2 kV Line to line 0 5 kV 1 kV Line to ground 0...

Page 29: ...1720 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation 217 Hz 2 0 3 28 1845 1970 2450 2400 2570 Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse modulation 217...

Page 30: ...ing to the KC regulations Indicates the device is approved according to the PSE regulations Indicates the device is approved according to the EAC regulations Caution Federal law United Stated of Ameri...

Page 31: ...r Consult the Instruction For Use on website address that is provided as eIFU indicator Indicates this device must not be thrown in the trash but must be recycled according to the European WEEE Waste...

Page 32: ...l disclaimer Disclaimer notice Although every attempt has been made to achieve technical accuracy in this document we assume no responsibility for errors that may be found Our goal is to provide you w...

Page 33: ...Tf 2 typical 14 ms Housing color Black front White border back IP connectivity 1x 10GbE Fiber Optic Interface for 24 FHD Nexxis link Optional 2x 10GbE Fiber Optic Interface for 1x mobile device conne...

Page 34: ...1 2 2014 ed4 EN 60601 1 2 2015 ed4 FCC part 15 Class ICES 001 Level Environmental EU RoHS China RoHS REACH Canada Health WEEE Packaging Directive Green compliance ROHS 3 REACH WEEE Supplied accessori...

Page 35: ...PC front DICOM button front Options configurable 1x Keyboard trackpad module available in different languages US DE FR IT TR ES Includes USB silicone mouse cleanable Power rating 100 240 VAC 50 60 Hz...

Page 36: ...20 x 1080 pixels Native UHD 3840 x 2160 pixels Pixel pitch 0 2745 mm 0 2796 mm Color imaging Yes Yes Gray imaging Yes Yes Bit depth 8 bpc 10 bpc Viewing angle H V 178 178 Ambient light sensor No No Ma...

Page 37: ...d certifications CE Medical Device Class I CCC China Safety specific IEC 60950 1 2005 A1 2009 EN 60950 1 2006 A1 2010 A11 2009 A12 2011 A2 2013 IEC 60601 1 2005 A1 2012 EN 60601 1 2006 A1 2013 A12 201...

Page 38: ...R5913897 00 MDMX MNA 38 Important information...

Page 39: ......

Page 40: ...R5913897 00 2021 01 21 Barco NV President Kennedypark 35 8500 Kortrijk Belgium Barco Visual Beijing Electronics Co Ltd Suzhou Branch Floor 4 No 179 Suhong West Road Suzhou Industrial Park 179 4 215021...

Reviews: