23

R5913897 /00

MDMX-MNA

Mission critical applications

We strongly recommend there is a replacement monitor immediately available in mission critical applications.

Moisture condensation

Do not use the product under rapid temperature and humidity change condition or avoid cold air from air-
conditioning outlet directly.

Moisture may condense on the surface or inside of the unit, or create a mist residue inside the protection
plate, this is not a malfunction of the product itself, although it may cause damage to the product.

If condensation happens, leave the product powered off, until there is no condensation.

Malfunctions

Disconnect the equipment from the mains supply and refer servicing to qualified service technicians under the
following conditions:

If the equipment does not operate normally when the operating instructions are followed. Adjust only those
controls that are covered by the operating instructions since improper adjustment of other controls may
result in damage and will often require extensive work by a qualified technician to restore the product to
normal operation.

If the product exhibits a distinct change in performance, indicating a need for service.

General warnings

The device has no means to be incorporated in an IT-network in the clinical environment.

The enclosure must be checked upon collision damage, refer to qualified service personnel.

The protective screen is made of tested high-resistance glass. Nonetheless there is the possibility that it
may crack if subject to strong impacts. Evaluate and prevent the risk of possible breakages of the
protective screen by correctly handling and positioning the product in the operating room.

The product is intended for indoor use

The product is not intended to be sterilized

The product has no applied parts, but the front side of the product and the steel enclosure have been
treated as applied part because considered accidentally touchable by the patient for a time <1 minute.

Handling the device

At end user application level it is necessary to foresee a backup unit in case there is no longer video input.

The MDMX-MNA must not be used for the diagnostic analysis of medical image data, the active monitoring
of a patient

s status or the primary transfer of data that will serve as a basis for the evaluation of a patient

s

condition. It is also unsuitable for use with data from which measures concerning the patient

s treatment

are derived.

The MDMX-MNA must not be used for the operation of any medical devices besides those provided and
installed by the manufacturer itself.

The MDMX-MNA can be used in conjunction with other imaging equipment and software, but only under
the premise that these are also exclusively intended for medical applications and comply with the
aforementioned restrictions of purpose.

After running continuously for an extended period of time, still images displayed on LCD monitors may
experience a memory-effect, whereby the image quality of the display is reduced.

Devices connected to the MDMX-MNA must be electrical safe and provide evidence of compliance with
IEC 60601-1.
Ensure that only I/O ports according to the intended use of this device are connected to the MDMX-MNA.
Do not connect devices with damaged or bypass isolation.

Check regularly that the visualization components of the MDMX-MNA are not damaged (e.g. scratches).
Do not operate the device if the display is damaged.

Do not allow to climb or rest on the equipment.

Barco is not liable for any damage or injury caused by mishandling or improper installation.

Important information

Summary of Contents for MDMX-MNA

Page 1: ...ENABLING BRIGHT OUTCOMES MDMX 22400 MDMX 25500 MDMX 22449 User Guide In wall console for the digital OR MDMX MNA...

Page 2: ...Barco Visual Beijing Electronics Co Ltd Suzhou Branch Floor 4 No 179 Suhong West Road Suzhou Industrial Park 215021 Suzhou China 179 4 www barco com en support www barco com...

Page 3: ...peration 15 3 1 On switching 16 3 2 Off switching 16 3 3 Stopwatch MDMX 22400 and MDMX 22449 16 3 4 DICOM PACS images optimization 16 3 5 Nexxis WorkSpot MDMX 25500 17 4 Cleaning and disinfection 19 4...

Page 4: ...R5913897 00 MDMX MNA 4...

Page 5: ...5 R5913897 00 MDMX MNA Welcome 1...

Page 6: ...ribed subject 1 2 About the product Overview Barco s MDMX MNA is an in wall console purpose built for multi image viewing in the digital operating room The MDMX MNA is an all in one central management...

Page 7: ...7 R5913897 00 MDMX MNA Image 1 1 MDMX 22400 Option GNTB Welcome...

Page 8: ...2400 Option GNTB MDMX 25500 Option GNNB MDMX 22449 Option GNTB Housing Powder coated steel Powder coated steel Powder coated steel Housing color front Black Black Black Front keyboard module 1x option...

Page 9: ...1 4 What s in the box Overview MDMX MNA console User guide and installation manual printed in English other languages can be found on the USB stick or online USB stick containing user documentation M...

Page 10: ...R5913897 00 MDMX MNA 10 Welcome...

Page 11: ...11 R5913897 00 MDMX MNA Parts controls and connectors 2...

Page 12: ...22449 Displays the time date and stopwatch function 2 Neutrik front connection For optional mobile Nexxis device connectivity 3 Mounting for keyboard module For optional keyboard module 4 USB 2 0 por...

Page 13: ...lectric connections on the front side of the device must be covered by their respective sealing caps 2 1 1 Nexxis button Overview The Nexxis button provides a trigger signal to the embedded MNA decode...

Page 14: ...R5913897 00 MDMX MNA 14 Image 2 4 Parts controls and connectors...

Page 15: ...15 R5913897 00 MDMX MNA Daily operation 3...

Page 16: ...light of the power button for external PC turns off 3 3 Stopwatch MDMX 22400 and MDMX 22449 Using the stopwatch The stopwatch status is displayed on the SmartBar and via LED lights 1 Press the Start R...

Page 17: ...ensed feature and can be activated by purchasing the WorkSpot license Nexxis WorkSpot provides the following features a composition of up to 6 video slots control each video source separately with the...

Page 18: ...R5913897 00 MDMX MNA 18 Image 3 2 For more details on how to use Nexxis WorkSpot see https www youtube com watch v lKAGOCYleCY Daily operation...

Page 19: ...19 R5913897 00 MDMX MNA Cleaning and disinfection 4...

Page 20: ...electing an alternative cleaning disinfecting product it is recommended to always identify the active ingredients In case of doubt about a certain cleaning product use plain water Do not use any of th...

Page 21: ...21 R5913897 00 MDMX MNA Important information 5...

Page 22: ...modules These batteries should be renewed every three years by authorized service personnel only Electrical Shock or Fire Hazard To prevent electric shock or fire hazard do not remove cover parts No...

Page 23: ...uct is intended for indoor use The product is not intended to be sterilized The product has no applied parts but the front side of the product and the steel enclosure have been treated as applied part...

Page 24: ...l service For details please visit the Barco website at http www barco com AboutBarco weee Turkey RoHS compliance T rkiye Cumhuriyeti AEEE Y netmeli ine Uygundur Republic of Turkey In conformity with...

Page 25: ...the use of hazardous substances in electrical and electronic product of Chinese Mainland marked with the Environmental Friendly Use Period EFUP logo The number inside the EFUP logo that Barco uses pl...

Page 26: ...thority of the Member State in which the user and or patient is established Factory address Barco Visual Beijing Electronics Co Ltd Suzhou Branch Floor 4 No 179 Suhong West Road Suzhou Industrial Park...

Page 27: ...might not offer adequate protection to radio frequency communication services The user might need to take mitigation measures such as relocating or re orienting the equipment Electromagnetic emissions...

Page 28: ...Mains power quality should be that of a typical commercial or hospital environment Surge IEC61000 4 5 Line to line 0 5 kV 1 kV Line to ground 0 5 kV 1 kV 2 kV Line to line 0 5 kV 1 kV Line to ground 0...

Page 29: ...1720 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation 217 Hz 2 0 3 28 1845 1970 2450 2400 2570 Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse modulation 217...

Page 30: ...ing to the KC regulations Indicates the device is approved according to the PSE regulations Indicates the device is approved according to the EAC regulations Caution Federal law United Stated of Ameri...

Page 31: ...r Consult the Instruction For Use on website address that is provided as eIFU indicator Indicates this device must not be thrown in the trash but must be recycled according to the European WEEE Waste...

Page 32: ...l disclaimer Disclaimer notice Although every attempt has been made to achieve technical accuracy in this document we assume no responsibility for errors that may be found Our goal is to provide you w...

Page 33: ...Tf 2 typical 14 ms Housing color Black front White border back IP connectivity 1x 10GbE Fiber Optic Interface for 24 FHD Nexxis link Optional 2x 10GbE Fiber Optic Interface for 1x mobile device conne...

Page 34: ...1 2 2014 ed4 EN 60601 1 2 2015 ed4 FCC part 15 Class ICES 001 Level Environmental EU RoHS China RoHS REACH Canada Health WEEE Packaging Directive Green compliance ROHS 3 REACH WEEE Supplied accessori...

Page 35: ...PC front DICOM button front Options configurable 1x Keyboard trackpad module available in different languages US DE FR IT TR ES Includes USB silicone mouse cleanable Power rating 100 240 VAC 50 60 Hz...

Page 36: ...20 x 1080 pixels Native UHD 3840 x 2160 pixels Pixel pitch 0 2745 mm 0 2796 mm Color imaging Yes Yes Gray imaging Yes Yes Bit depth 8 bpc 10 bpc Viewing angle H V 178 178 Ambient light sensor No No Ma...

Page 37: ...d certifications CE Medical Device Class I CCC China Safety specific IEC 60950 1 2005 A1 2009 EN 60950 1 2006 A1 2010 A11 2009 A12 2011 A2 2013 IEC 60601 1 2005 A1 2012 EN 60601 1 2006 A1 2013 A12 201...

Page 38: ...R5913897 00 MDMX MNA 38 Important information...