5. Mechanical setup of display wall with pedestals
5.4.4
Installation of the second row
Pedestal 63
In case of HVD:
Remove the left (or right) spacers
NEVER remove the horizontal profile completely
from the vertical profiles.
Proceed like this:
Start with the left (or right) side.
Open the screws which fix the horizontal profile
to the vertical profile (2x B361304 SCR ASS D188K
M8X25 STZN).
While the right (or left) side of the horizontal pro-
file is still fixed to the vertical profile, push the
horizontal profile back to remove the spacer.
Subsequently restore the position of the horizon-
tal profile.
Use 2x B361304 SCR ASS D188K M8X25 STZN and
fix the horizontal profile to the left (or right) ver-
tical profile.
LEVEL the horizontal profile to maintain the refer-
ence distance!
Subsequently remove the right (or left) spacer.
Perform these steps also on the right (or left) side
to remove the spacer on the right (or left).
Make sure that you keep and maintain the posi-
tion of the horizontal profile!
Pedestal 64
The difference in height of the panels requires to
check/adjust the position of the horizontal profile
with the front access mount.
Therefore jig R872756 is included in the delivery.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017 _____________________________________________________________ 54