5. Mechanical setup of display wall with pedestals
5
Mechanical setup of display wall with pedestals
5.1
Overview
The front mount system for displays comprises 3 parts: the pedestal (standard heights: 875mm, 1000mm,
1200mm, 1500mm), the front access mount module and the display.
The pedestals are setup with/without spacer depending on the display.
WRT width: The front access mount module is used as is (in case of KVD/IVD) or the spacers are removed (HVD).
The front access mount module is mounted onto the pedestal.
Check/adjust the distance between the top horizontal profile of the pedestal and the horizontal profile of the
display module.
The display is mounted to the front access mount module.
For stability reasons the system has to be fixed to the floor (via the floor brackets) and to the wall (short / long
wall fixation).
Every column of the system has to be grounded!
This is the installation sequence:
Make a grid on the wall of the room where to fix the display wall.
Drill the holes into the wall.
Apply the required anchors.
Mount the fixation brackets (wall side)
Setup of all pedestals.
All pedestals are connected (either linear or curved).
The first row is mounted onto the pedestals
In case of more rows: mount the second (and third) row.
Attach the wall fixation brackets to the system (pedestal, third (or second) row).
If applicable, mount the following rows
Every third row has to be fixed to the wall.
When all rows have been mounted and fixed according the rules mentioned above, the displays are mounted.
The structure is made of aluminum profiles, with a cross section of 90x45 or 45x45, respectively. Profiles are
connected using alu corner brackets and "long nippled" hammer bolts B361304, M8x25.
There are two flavors of front access mounts, with air channel (legacy NSL-5521, left) and without air
channel (OVD/IVD/KVD/HVD, right).
Most of the drawings show the system with air channel (but be aware that KVD/IVD/HVD/OVD DO NOT have
front access mount with air channels!) The installation steps refer to both, systems with and systems without air
channel.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017 _____________________________________________________________ 25