background image

26-0904001-00 Rev 00.00 

 

User’s Guide Addendum 

 
 
 

Copyright 

 

© Barco. June 12, 2012 
All rights reserved. No part of this document may be copied, reproduced or translated. It 
shall not otherwise be recorded, transmitted or stored in a retrieval system without the prior 
written consent of Barco. 

 

Notice 

 

Barco provides this manual “as is” without warranty of any kind, either expressed or 
implied, including but not limited to the implied warranties or merchantability and fitness for 
a particular purpose. Barco may make improvements and/or changes to the product(s) and/ 
or the program(s) described in this publication at any time without notice. 
This publication could contain technical inaccuracies or typographical errors. Changes are 
periodically made to the information in this publication; these changes are incorporated in 
new editions of this publication. 

 

Federal Communications Commission (FCC) Statement 

 

This equipment has been tested and found to comply with the limits for a class A digital 
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communications. Operation of this equipment in a residential 
area may cause harmful interference, in which case the user will be responsible for 
correcting any interference. 

 

Guarantee and Compensation 

 

Barco provides a guarantee relating to perfect manufacturing as part of the legally 
stipulated terms of guarantee. On receipt, the purchaser must immediately inspect all 
delivered goods for damage incurred during transport, as well as for material and 
manufacturing faults Barco must be informed immediately in writing of any complaints. 
The period of guarantee begins on the date of transfer of risks, in the case of special 
systems and software on the date of commissioning, at latest 30 days after the transfer of 
risks. In the event of justified notice of compliant, Barco can repair the fault or provide a 
replacement at its own discretion within an appropriate period. If this measure proves to be 
impossible or unsuccessful, the purchaser can demand a reduction in the purchase price or 
cancellation of the contract. All other claims, in particular those relating to compensation for 
direct or indirect damage, and also damage attributed to the operation of software as well 
as to other services provided by Barco, being a component of the system or independent 
service, will be deemed invalid provided the damage is not proven to be attributed to the 
absence of properties guaranteed in writing or due to the intent or gross negligence on the  
part of Barco. 
 
If the purchaser or a third party carries out modifications or repairs on goods delivered by 
Barco, or if the goods are handled incorrectly, in particular if the systems are commissioned 
operated incorrectly or if, after the transfer of risks, the goods are subject to influences not 
agreed upon in the contract, all guarantee claims of the purchaser will be rendered invalid. 

Summary of Contents for ImagePRO-II

Page 1: ...ImagePRO II Dual Output User s Guide Addendum Manual 26 0904001 00 Revision 00...

Page 2: ...ble for correcting any interference Guarantee and Compensation Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee On receipt the purchase...

Page 3: ...ks registered trademarks or copyrights of their respective holders All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for th...

Page 4: ...e ground connection by way of grounding conductor in the power cord is essential for safe operation Grounding the Product This product is grounded through the grounding conductor of the power cord To...

Page 5: ...26 0904001 00 Rev 00 00 5 Change History The table below lists the changes to the User s Guide Addendum Rev Date ECP Description Approved By 00 6 22 12 597847 Initial Release R Pellicano...

Page 6: ...tput Connector Map 8 3 Output Configuration 9 Output Resolution 9 Area of Interest 9 Output Timing Adjustment 9 Output Effects 10 Genlock 10 Save and Reset Output Configs 11 Pan Zoom 11 Logo Backup an...

Page 7: ...erest Effects or even Pan Zoom settings giving the operator maximum flexibility for a given show configuration 1 Getting Started To get started make sure you have an ImagePRO II Dual Output unit R9004...

Page 8: ...menu scroll to and select the OUTPUT CONNECTOR MAP submenu 2 By default all seven outputs of the ImagePRO II will be mapped to Output A 3 Scroll to the various connectors as required and change the fi...

Page 9: ...ms to change the output resolution frame rate to the desired choice Area of Interest 1 Select the AREA OF INTEREST submenu under OUTPUT 2 The first field labelled CHANNEL allows the selection of A or...

Page 10: ...N 3 The second field in the menu CHB SOURCE will default to LOCK TO A With this option Channel B will stay locked to Channel A at all times regardless of the Genlock source selected for Channel A If d...

Page 11: ...ZOOM button on the front panel of the ImagePRO II 2 The first field labelled CHANNEL allows the selection of A or B to allow independent Pan and Zoom adjustments for each output channel 3 The same ope...

Page 12: ...g Dual2K mode b All output connectors are assigned to Channel A c A Logo saved in Single mode will be available for both Channel A and Channel B d Channel B Genlock will default to Lock to A 4 When in...

Page 13: ...Size pixels mask option to set the mask window left Mask Left in percentage right Mask Right in percentage top Mask Top in percentage bottom Mask Bottom in percentage at aspect ratio type 0 6 see bel...

Page 14: ...when Dual option mezzanine installed Aspect Ratio type 0 1 1 1 3 2 2 4 3 3 5 4 4 16 10 5 16 9 6 Custom Use ar to specify actual aspect ratio IMGR Description Input Manager Settings Parameters acq acqu...

Page 15: ...nnector for output connectors Parameters ocon output connector 0 6 see below for connector numbers ch channel select 0 1 syncpol sync polarity 0 H V 1 H V 2 H V 3 H V bitdepth color bit depth 0 6bit 1...

Page 16: ...de Operation Mode conmode Encore Connect Mode unitid Encore Unit ID encoreip Encore IP Address UINPUT Description Input Settings Required parameters con connector itype input type for commands to DVI...

Page 17: ...ng based from format table name format name This command option simply renames the current format hsync horizontal sync hact horizontal active hfp horizontal front porch hpos horizontal position htot...

Page 18: ...following format VIDCOL brt ovr bright cbrt R bright G bright b bright cnt ovr contr ccnt R contr G contr B contr sat saturation hue hue cinv invert csp colorspace gamma gamma mono monochrome Query F...

Page 19: ...values VIEW con connector ch channel pixel Query Response 1 View Settings in the following format VIEW hpos h pos vpos v pos hsize h size vsize v size Connectors 0 DVI 1 D15 2 HDMI 3 DP 4 SDI1 5 SDI2...

Reviews: