background image

 

 

 

0. GENERAL DEFINITIONS 

 

Abbreviations 
 

CE  

European Conformity 

DEMKO 

Danish Conformity Mark 

CCFL  

Cold Cathode Fluorescent Lamp 

CSA  

Canadian Standardisation Authority 

CVBS  

Composite Video Blanking and Sync 

DVI  

Digital Visual Interface 

EEDID  

Enhanced Extended Display Identification Data 

EMC  

Electromagnetic Compatibility 

ESD  

Electrostatic Discharge 

FCC  

Federal Communications Commission 

FRU  

Field Replaceable Unit 

HDP  

Hot Plug Detect (DVI) 

IEC  

International Electrotechnical Commission (Standards) 

 

60601-1 Medical electrical equipment requirements 

LCD  

Liquid Crystal Display 

LUT  

Look-Up Table 

LVDS  

Low voltage differential signal 

MTBF  

Mean Time Between Failure 

MTTR  

Mean Time To Replace 

OSD  

On Screen Display 

PCA  

Printed Circuit Assembled 

RFI  

Radio Frequency Interference 

SDI  

Serial Digital Interface 

SMPTE  

Society of Motion Picture and Television Engineers 

SOG  

Sync On Green (monochrome video) 

S-VIDEO  

Separated Video Y/C ;    

Y= luminance 

 

 

 

 

 

C= color 

TMDS  

Transition Minimized Differential Signalling 

UL 

Underwriters Laboratories inc. 

VESA  

Video Electronics Standards Association 

VGA  

Video Graphics Adapter 

WEEE  

Waste Electrical and Electronic Equipment 

ROHS 

Restriction of Hazardous Substances 

REACH 

Registration Evaluation Authorization and Restriction of Chemical 

 

Substances 

 
Units of measurement 

 
Length  

m  

meter, 

Time  

s  

second 

Voltage  

V  

Volt, 

Current  

A  

Ampere, 

Power  

W  

Watt 

Resistance  

Ω  

Ohm 

Weight  

kg  

Kilogram 

Luminance  

Cd/m²  

Candela per square meter 

Illuminance  

lx  

lux 

Temperature  

°C  

degrees Celsius 

Frequency  

Hz  

Hertz (Cycles per second) 

Noise level  

dB(A)  

dBspl A weighted 

Magnetic field  

T  

Tesla (= 10000 Gauss) 

 

 

Summary of Contents for FIMI MDSC8156

Page 1: ...1 56 2inch LCD Large Screen Monitor MDSC8156...

Page 2: ...n Display PCA Printed Circuit Assembled RFI Radio Frequency Interference SDI Serial Digital Interface SMPTE Society of Motion Picture and Television Engineers SOG Sync On Green monochrome video S VIDE...

Page 3: ...gical Hazard and Returns 9 2 10 Cleaning Instruction 10 3 DISPOSAL OF THE LCD MONITOR 12 3 1 Directive 2002 96 EC on waste of electrical and electronic equipment WEEE 13 3 2 Directive 2002 95 EC on th...

Page 4: ...onitor On and Off 29 10 2 4 Brightness Control 29 11 ON SCREEN DISPLAY OSD 30 11 1 Menu structure 30 11 2 OSD Controls ON Screen Display 32 11 2 1 Working in the OSD Menu 32 11 2 2 Main OSD Menu 32 11...

Page 5: ...adjustments are provided The display can also be controlled by remote through a serial or Ethernet communication link The MDSC8156 shall be supplied with VESA 400 mounting interfaces This monitor foll...

Page 6: ...language or format The monitor described in this manual has been certified registered by the safety agencies regulatory authorities as model n BA56DS 1 1 EMC Notice 1 1 1 FCC This equipment has been t...

Page 7: ...O RAIN OR EXCESSIVE MOISTURE THE ENCLOSURE HAS TO BE CHECKED UPON COLLISION DAMAGE REFER TO QUALIFIED SERVICE PERSONNEL 2 1 Power cord Due to the different power cable lengths necessary at system leve...

Page 8: ...ipherals must follow the requirements of clause 16 of IEC60601 1 3rd ed and Table BBB 201 of IEC 60601 1 1 for the medical electrical systems 2 4 Handling Do not press on or scratch the LCD screen Do...

Page 9: ...equate backup solution has to be provided at medical system level This monitor can be repaired only by trained service personnel contact your local dealer to get assistance FIMI will make available on...

Page 10: ...g citric acid Degreasing agent e g acetone methylene chloride trichloroethylene petrol Strong ammonia detergents e g toilet cleaner Chlorine resp Hypochloride detergents e g Chavel water Domestos Solv...

Page 11: ...oduct Wipe with a soft cotton cloth Cabinet Clean the cabinet using a soft cotton cloth lightly moistened with a recognized cleaning product for medical equipment Repeat with water only Wipe with a so...

Page 12: ...es in the disposal of the product The monitor s packaging is re usable please retain the packaging for future use Do not dispose of this monitor with general household waste The fluorescent lamps in t...

Page 13: ...recycling please contact your local city office or your supplier s office For countries outside the European Union Disposal of electrical products in countries outside the European Union should be do...

Page 14: ...OFF Not illuminated 0 W Factory Setting This step is only executed if Splash Screen feature is enabled 4 TECHNICAL INFORMATION Display Panel supplier Chi Mei Optoelectronics Display Model Name V562D1...

Page 15: ...utputs 5V x 4 3 5 mm plug near DVI plug Max 1A from each connector total max current 2Amp Mains voltage range 100 240 Vac 50 60Hz 2 5 5 5Amp Ingress Protection only GR version IP21 The degree of prote...

Page 16: ...16 5 DIMENSIONS MDSC8156 family 1350 814 Bottom View Front View...

Page 17: ...17 Side View...

Page 18: ...18 General View for display without protective glass...

Page 19: ...19 General View for display with protective glass...

Page 20: ...sure if these equipments require any change of setting 6 1 Position of Use WARNING When positioning this equipment ensure that the mains plug and socket are easily accessible While unpacking the moni...

Page 21: ...itor is provided with VESA 400 mounting interface evaluated with a safety factor 6 a suitable mechanical suspension has to be provided in the final installation not provided not provided M6 screw s no...

Page 22: ...22 7 HANDLING PRECAUTIONS The support system of the 56 monitor must be designed in accordance with the requirements of IEC 60601 1 standard appropriate tensile factor...

Page 23: ...placed in the field the packaging has been studied to be reused the top and bottom covers of the packaging are equal so you can remove the top and use it as the bottom for the return shipping and use...

Page 24: ...ng AC Power Plug the receptacle end of the cord set into the AC power adapter then plug the power connector of the adapter into the power port of the monitor This power port is located on the back of...

Page 25: ...wed The 5V is available on the 4 plugs marked with warning labels and on the pin 16 of each DVI connector All the 5V connections are in parallel a maximum current of 500mA can be drawn from each conne...

Page 26: ...T M D S Pin 24 CK_RX T M D S DVI 2 input Microcross DVI D female connector Pin 1 D2_RX T M D S Pin 13 D3_RX T M D S Pin 2 D2_RX T M D S Pin 14 5V from the video source system Pin 3 GND Data 2 shield P...

Page 27: ...Pin 22 GND Clock shield Pin 11 GND Data 1 shield Pin 23 CK_RX T M D S Pin 12 D3_RX T M D S Pin 24 CK_RX T M D S RS 232 Main communication interface for FW upgrade monitor management and data exchange...

Page 28: ...When main menu or sub menu is active it allows to move or scroll to the previous up item or increase the selected parameter Down When main menu or sub menu is active it allows to move or scroll to the...

Page 29: ...ch when the Mains Switch is switched on again the monitor will execute the initialization phase and then will turn off because it was the stored status just press the Power On Off key to switch on the...

Page 30: ...UT MODE DVI PWR IN DVI PWR OUT REMAIN LIFE OUT MODE NATIVE DICOM FACTORY DICOM USER COLOR FACTORY COLOR USER A description of the OSD structure is shown below USER SETTING DICOM OFFSET COLOR TEMP GAMM...

Page 31: ...SABLE 10 1 PRODUCT INFO SERVICE SPLASH SCREEN YES NO INPUT MODE SINGLE LINK DUAL LINK OUTPUT POWER ON OFF KEY LOCK OFF SERVICE FULL LEFT to RIGHT TOP to BOTTOM MODEL PRODUCT NUM SERIAL NUM HW REL FW R...

Page 32: ...by the upper menu window 5 Press the Esc key to go back to the root OSD menu level and then to exit from the OSD 11 2 2 Main OSD Menu Press the Enter key to display the Main Menu or the request to in...

Page 33: ...monitor output is corrected according to the color temperature pre setted in the factory 6500 K In the menu the string COLOR is replaced with the current color temperature i e ____6500 K FACTORY ____...

Page 34: ...ed when in COLOR USER mode GAMMA COMP The color gamma from 1 4 to 3 2 in 0 1 steps can be adjusted when in COLOR USER mode This can be useful i e to adjust the color depending on the type of content d...

Page 35: ...nd is not a defect TIME OUT OSD When the OSD menu is displayed and no key is pressed it will disappear after the time setted up in this parameter It is possible to choose among the following values 10...

Page 36: ...ing the meaning of each item of this menu 11 2 7 Product Info MOD Model Type P N Product Number S N Serial Number H W Hardware release F W Firmware release FSL FPGA Single Link firmware release FDL FP...

Page 37: ...nversion dongles KEY LOCK This allows to enable the key lock at different menu levels If enabled entering the OSD will display a Request for Password window The password is made up by four characters...

Page 38: ...sword Password KO Password OK NOTE There is no max tentative numbers for inserting the correct password NOTE Default password is 1224 _ _ _ _ _ _ MONITOR INFO OUT MODE USER SETTING OSD SETTING PRODUCT...

Page 39: ...l 2 Lines Ver Back Porch 45 Lines NOTE The video signals must be synchronous with respect to each other Dual Link Mode 3840x2160 2 x DVI Dual Link inputs each at 1920x2160 60Hz For each 1 3 Dual Link...

Page 40: ...Tx Data 7 not used 3 Rx Data 8 not used 4 not used 9 not used 5 Ground 13 2 LAN Interface A LAN interface is provided to allow the following function single LAN connection default with connector locat...

Page 41: ...ode FIMI 00 Technical level yy Year 11 2011 ww Week 01 to 52 nnnnnn progressive number Type number Code number 12NC Model number Manufacturing Date Factory address BARCO K code 14 IDENTIFICATION LABEL...

Page 42: ...Content MDSC8156 GR full version with protection glass redundant power supply MDSC8156 R light version w o protection glass with redundant power supply MDSC8156 basic version w o protection glass red...

Page 43: ...ntenance are provided The information should be read carefully WARNING dangerous voltage Disconnect supply before service Compliance with 2002 96 EC WEEE Directive Consult instructions for use Complia...

Page 44: ...IMI S r l Saronno Italy All rights are reserved Reproduction in whole or in part is prohibited without the written consent of the copyright owner Printed in Italy Rev 1 3 4519 206 1076 1 a451920610761...

Reviews: