Immunity to RF wireless communications equipment
Test
frequency
(MHz)
Band (MHz)
Service
Modulation
Maximum
power (W)
Distance
(m)
Immunity
test level (V/
m)
385
380
–
390
TETRA 400
Pulse
modulation
18 Hz
1.8
0.3
27
450
430
–
470
GMRS 460,
FRS 460
FM ± 5 kHz
deviation
1 kHz sine
2
0.3
28
710
704
–
787
LTE Band
13, 17
Pulse
modulation
217 Hz
0.2
0.3
9
745
780
810
800
–
960
GSM 800/
900, TETRA
800, iDEN
820, CDMA
850, LTE
Band 5
Pulse
modulation
18 Hz
2
0.3
28
870
930
1720
1700
–
1990
GSM 1800,
CDMA 1900,
GSM 1900,
DECT, LTE
Band 1/3/4/
25, UMTS
Pulse
modulation
217 Hz
2
0.3
28
1845
1970
2450
2400
–
2570
Bluetooth,
WLAN,
802.11 b/g/n,
RFID 2450,
LTE Band 7
Pulse
modulation
217 Hz
2
0.3
28
5240
5100
–
5800
W LAN
802.11 a/n
Pulse
modulation
217 Hz
0.2
0.3
9
5500
5785
5.6 Explanation of symbols
Symbols on the device
On the device or power supply, you may find the following symbols (nonrestrictive list):
Indicates the device meets the requirements of the applicable EC directives.
Indicates compliance with Part 15 of the FCC rules (Class A or Class B)
E346057
Indicates the device is approved according to the UL regulations for Canada and US
Summary of Contents for Eonis MDRC-2321
Page 4: ...R5910551 00 Eonis 4...
Page 8: ...R5910551 00 Eonis 8 Welcome...
Page 12: ...R5910551 00 Eonis 12 Installation...
Page 13: ...13 R5910551 00 Eonis Operation 3...
Page 20: ...R5910551 00 Eonis 20 Operation...
Page 21: ...21 R5910551 00 Eonis Maintenance 4...
Page 23: ...23 R5910551 00 Eonis Important information 5...