background image

ENABLING BRIGHT OUTCOMES

MDRC-2321 (option STIB)

MDRC-2321 (option SNIB)

MDRC-2321 (option HTIB)

MDRC-2321 (option HNIB)

User Guide

21-inch clinical display

Eonis

Summary of Contents for Eonis MDRC-2321

Page 1: ...ENABLING BRIGHT OUTCOMES MDRC 2321 option STIB MDRC 2321 option SNIB MDRC 2321 option HTIB MDRC 2321 option HNIB User Guide 21 inch clinical display Eonis...

Page 2: ...Factory FIMI S r l Via Saul Banfi 1 21047 Saronno Italy Registered office FIMI S r l Via Vittor Pisani 6 20124 Milano Italy www barco com en support www barco com...

Page 3: ...color space 16 3 9 QAWeb presets 16 3 10 Display functions 16 3 11 White point selection 17 3 12 Analog video settings 18 3 13 Power save mode 18 3 14 OSD menu language 18 3 15 OSD menu orientation 19...

Page 4: ...R5910551 00 Eonis 4...

Page 5: ...321 Display version Brightness Front cover Power supply Housing color MDRC 2321 option SNIB Standard brightness None Internal power supply Black MDRC 2321 option STIB Standard brightness PCAP touchscr...

Page 6: ...designed for this display and is the ideal protection during transport and storage 1 2 Product overview Front 3 4 2 1 Image 1 1 1 Display stand 2 Control wheel Push long 5 sec to put display in stand...

Page 7: ...Blinking green Display is entering standby mode Steady orange Display in standby mode Back 8 9 1 2 3 4 6 7 5 Image 1 2 1 Kensington security slot 2 USB B 2 0 upstream connector 3 USB A 2 0 downstream...

Page 8: ...R5910551 00 Eonis 8 Welcome...

Page 9: ...ARNING Sufficient expertise is required to install this equipment All devices and complete setup must be tested before taking into operation CAUTION When the display is assembled in the medical system...

Page 10: ...1 2 Connect the USB upstream connector to a PC USB host to make use of QAWeb or any of the display USB downstream connectors e g to connect a keyboard mouse or other peripheral Image 2 2 3 Connect th...

Page 11: ...put is landscape If you use the display in portrait mode make sure you change the orientation of the video input via the screen settings of the computer 2 3 VESA mount installation To mount the displa...

Page 12: ...R5910551 00 Eonis 12 Installation...

Page 13: ...13 R5910551 00 Eonis Operation 3...

Page 14: ...derstand pixel technology LCD displays use technology based on pixels As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or permanently lit w...

Page 15: ...menu 3 Enter the Power Status LED submenu 4 Change the behavior of the power status LED as desired and confirm 3 5 Control wheel locking unlocking About To avoid unwanted or accidental activation of t...

Page 16: ...disabled To select sRGB color space 1 Bring up the OSD main menu 2 Navigate to the Adjustments menu 3 Select sRGB and confirm 3 9 QAWeb presets About QAWeb presets Display function white point selecti...

Page 17: ...g room into account The available reading room options are Darkroom Selects DICOM calibrated function optimized for darkroom conditions 0 50 Lux Office Selects DICOM function optimized for office cond...

Page 18: ...og menu 3 Adjust one of the available analog video settings as desired 3 13 Power save mode About power save mode Enabling power save mode on your MDRC 2321 will optimize the display lifetime by autom...

Page 19: ...y reset About factory reset A factory reset allows you to fully restore the display to its original factory setting To perform a factory reset 1 Bring up the OSD main menu 2 Navigate to the Adjustment...

Page 20: ...R5910551 00 Eonis 20 Operation...

Page 21: ...21 R5910551 00 Eonis Maintenance 4...

Page 22: ...quid may cause damage to internal electronics Instead apply the liquid to a cleaning cloth To clean the display Clean the display using a sponge cleaning cloth or soft tissue lightly moistened with a...

Page 23: ...23 R5910551 00 Eonis Important information 5...

Page 24: ...acility that is intended for use where contact with a patient is unlikely no applied part The equipment shall not be used with life support equipment The user should not touch the equipment nor its si...

Page 25: ...idity change condition or avoid cold air from air conditioning outlet directly Moisture may condense on the surface or inside of the unit or create a mist residue inside the protection plate this is n...

Page 26: ...h other municipal waste Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment To prevent possible ha...

Page 27: ...ials for this part is below the limit requirement in GB T 26572 x GB T 26572 x Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this par...

Page 28: ...rea Contra Indications This display is not intended to be used for direct diagnosis and therapeutic interventional radiology Manufacturing country The manufacturing country of the product is indicated...

Page 29: ...used no closer than 30 cm 12 inches to any part of the MDRC 2321 including cables specified by the manufacturer Otherwise degradation of the performance of this equipment could result Electromagnetic...

Page 30: ...f a typical commercial or hospital environment Surge IEC61000 4 5 Line to line 0 5 kV 1 kV Line to ground 0 5 kV 1 kV 2 kV Line to line 0 5 kV 1 kV Line to ground 0 5 kV 1 kV 2 kV Mains power quality...

Page 31: ...0 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation 217 Hz 2 0 3 28 1845 1970 2450 2400 2570 Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse modulation 217 Hz 2 0 3...

Page 32: ...ng to the EAC regulations Caution Federal law United Stated of America restricts this device to sale by or on the order of a licensed healthcare practitioner Indicates the device is approved according...

Page 33: ...if not handled carefully when being stored Indicates a device that needs to be protected from moisture when being stored Indicates the storage direction of the box The box must be transported handled...

Page 34: ...other use duplication or disclosure of a Barco software product in any form is authorized Trademarks All trademarks and registered trademarks are property of their respective owners Copyright notice...

Page 35: ...pe 477 0 x 411 5 529 6 x 201 3 mm Dimensions w o stand W x H x D Portrait 477 0 x 374 5 x 70 4 mm Landscape 374 5 x 477 0 x 70 4 mm Dimensions packaged W x H x D 660 x 513 x 230 mm Net weight with sta...

Page 36: ...ing Directive Supplied accessories 1x DisplayPort video cable 1x USB cable 1x printed User Guide English 1x system disc containing MediCal QAWeb software graphics board drivers and translations of the...

Page 37: ...R5910551 00 Eonis 37 Important information...

Page 38: ...istered office FIMI S r l Via Vittor Pisani 6 20124 Milano Italy Factory FIMI S r l Via Saul Banfi 1 21047 Saronno Italy www barco com R5910551 00 2019 03 21 FIMI S r l Vittor Pisani 6 20124 Milano It...

Reviews: