background image

Copyright ©

All rights reserved. No part of this document may be copied, reproduced or translated. It shall not otherwise be recorded, transmitted or
stored in a retrieval system without the prior written consent of Barco.

Guarantee and Compensation

Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee. On receipt, the purchaser
must immediately inspect all delivered goods for damage incurred during transport, as well as for material and manufacturing faults Barco
must be informed immediately in writing of any complaints.

The period of guarantee begins on the date of transfer of risks, in the case of special systems and software on the date of commissioning,
at latest 30 days after the transfer of risks. In the event of justified notice of compliant, Barco can repair the fault or provide a replacement
at its own discretion within an appropriate period. If this measure proves to be impossible or unsuccessful, the purchaser can demand a
reduction in the purchase price or cancellation of the contract. All other claims, in particular those relating to compensation for direct or
indirect damage, and also damage attributed to the operation of software as well as to other services provided by Barco, being a component
of the system or independent service, will be deemed invalid provided the damage is not proven to be attributed to the absence of properties
guaranteed in writing or due to the intent or gross negligence or part of Barco.

If the purchaser or a third party carries out modifications or repairs on goods delivered by Barco, or if the goods are handled incorrectly,
in particular if the systems are commissioned operated incorrectly or if, after the transfer of risks, the goods are subject to influences not
agreed upon in the contract, all guarantee claims of the purchaser will be rendered invalid. Not included in the guarantee coverage are
system failures which are attributed to programs or special electronic circuitry provided by the purchaser, e.g. interfaces. Normal wear as
well as normal maintenance are not subject to the guarantee provided by Barco either.

The environmental conditions as well as the servicing and maintenance regulations specified in the this manual must be complied with by
the customer.

Changes

Barco provides this manual ’as is’ without warranty of any kind, either expressed or implied, including but not limited to the implied war-
ranties or merchantability and fitness for a particular purpose. Barco may make improvements and/or changes to the product(s) and/or the
program(s) described in this publication at any time without notice.

This publication could contain technical inaccuracies or typographical errors. Changes are periodically made to the information in this
publication; these changes are incorporated in new editions of this publication.

Trademarks

Brand and product names mentioned in this manual may be trademarks, registered trademarks or copyrights of their respective holders.
All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for
the products or their manufactures.

Summary of Contents for Custom power box

Page 1: ...Custom power box Owners manual R5976620 02 05 06 04 ...

Page 2: ...Barco nv Media Noordlaan 5 B 8520 Kuurne Phone 32 56 36 89 70 Fax 32 56 36 88 24 E mail media barco com Visit us at the web www barco com Printed in Belgium ...

Page 3: ...ce or part of Barco If the purchaser or a third party carries out modifications or repairs on goods delivered by Barco or if the goods are handled incorrectly in particular if the systems are commissioned operated incorrectly or if after the transfer of risks the goods are subject to influences not agreed upon in the contract all guarantee claims of the purchaser will be rendered invalid Not inclu...

Page 4: ......

Page 5: ... Power Box 5 2 3 Technical summary 6 3 Cables used with the custom power box 7 3 1 Order info power cables 7 4 Physical installation 9 4 1 Components of a Custom Power Box 9 4 2 Installation 10 4 3 Connections between custom power box and LED wall 11 5 Addendum 13 5 1 Identification system of a power distribution network according IEC 364 13 Index 15 R5976620 CUSTOM POWER BOX 05 06 04 1 ...

Page 6: ...Table of contents 2 R5976620 CUSTOM POWER BOX 05 06 04 ...

Page 7: ...g to qualified service technicians personnel only Do not use this power box with an IT power distribution network A neutral conductor must be provided 1 2 Important Warnings Important warnings Risk of electrical shock Image 1 1 Risk of electric shock Do not open To reduce the risk of electric shock do not remove cover or back No user serviceable parts inside Refer servicing to qualified service pe...

Page 8: ...1 Safety 4 R5976620 CUSTOM POWER BOX 05 06 04 ...

Page 9: ... pole output connectors and 1 auxiliary outlet R9851241 Custom Power Box 3 phase 230VAC 3 multi pole output connectors and 1 auxiliary outlet R9851242 Custom Power Box 3 phase 230VAC 4 multi pole output connectors and 1 auxiliary outlet R9851243 Custom Power Box 3 phase 230VAC 5 multi pole output connectors and 1 auxiliary outlet R9851244 Custom Power Box 3 phase 230VAC 6 multi pole output connect...

Page 10: ...Power boxes with four or more multi pole output connectors are provided with a ground fault current interrupter adjustable between 30 mA and 10 mA Multi pole output connectors 19 pins circular multi pole connectors with each 6 circuits Each circuit is protected with a 16 A switch fuse 20 kA short circuit rating Auxiliary connector 2 phase plus protective earth auxiliary connectors CEE form protect...

Page 11: ...door use Used to distribute power between custom power box and spider connector image 3 1 image 3 2 R9851660 Waterproof spider connector for outdoor use with 6 power outputs C19 with different length Spider support bracket included Used to subdivide power from a multi power cable to a group of tiles image 3 3 image 3 6 R9851661 Waterproof spider connector for outdoor use with 6 power outputs C19 w...

Page 12: ... connector plug Image 3 3 Waterproof spider connector output cables with different length Image 3 4 Waterproof spider connector output cables with same length Image 3 5 Spider connector for indoor use output cables with same length Image 3 6 Spider support bracket 8 R5976620 CUSTOM POWER BOX 05 06 04 ...

Page 13: ... breaker is switched on Image 4 1 A Control lamp MAIN BREAKER ON B Auxiliary outlet C Multi pole power output connector D Multi pole power output connector E Multi pole power output connector F Multi pole power output connector G Door key Circuit breakers There are 6 circuit breakers provided per multi pole output connector The circuit breakers are marked with a letter which correspond to the lett...

Page 14: ...ckside of the Custom Power Box is provided with a fixed M8 nut Use for every nut a M8 x 25 mm bolt for fastening the Custom Power Box image 4 3 2 Open the door of the Custom Power Box and place all the circuit breakers in the OFF position 3 Remove the lower cover plate inside the Custom Power Box by releasing four crosshead screws 4 Guide the incoming power cable through the cable seal at the bott...

Page 15: ...tom power box is provided with multi pole power output connectors One multi pole connector contains six 6 power circuits each protected with a 16 ampere rated circuit breaker A multi power cable is used to transport the power from the multi pole connector to a spider connector This spider connector subdivide the power circuits into individual power source cables Each power source cable of the spid...

Page 16: ...er connector will easily connect to the start point of a power branch 2 Fasten the multi pole plug of a spider connector inside the spider support bracket Warning Always use waterproof spider connectors in case of an outdoor LED wall application 3 Connect a single power source cable of the spider connector with the start point of a power branch of tiles in the LED wall 4 Repeat step 3 until all si...

Page 17: ...an impedance The second character indicates the grounding manner of electrical equipment T Directly connected with the protective earth N Connected with the neutral conductor of the power source The third character indicates the situation of the neutral N conductor and the protective earth PE conductor C Common conductor for neutral and protective earth S Separated conductors for neutral and prote...

Page 18: ...5 Addendum 14 R5976620 CUSTOM POWER BOX 05 06 04 ...

Page 19: ...er box 11 Custom Power Box 5 6 Technical summary 6 F Functionality 5 I IEC 364 13 Installation 9 10 O Order info 5 7 P Power box 11 Connections 11 S Safety 3 Important Safety Instructions 3 Important Warnings 3 T Technical summary 6 R5976620 CUSTOM POWER BOX 05 06 04 15 ...

Reviews: