![background image](http://html1.mh-extra.com/html/barco/barcoreality-sim6-ultra-r9040150/barcoreality-sim6-ultra-r9040150_owners-manual_3931548044.webp)
5. Random Access
How to install the correct settings for the options in the Edit file menu.
EDIT FILE OPTIONS
Source number
1
Clamp delay
0
Clamp width
10
Field polarity
[pos]
Select with
↑
or
↓
<ENTER> to toggle
↑
or
↓
to change value
<EXIT> to return
Menu 5-11
Source number
The source number of a non-active source can be changed to any other source number. This makes
it possible to create a file for future source numbers.
Clamp delay
The time between the leading edge of the clamp pulse and the locked edge of the sync pulse. Can be
any value between 0 and 255. Change the value by pushing the cursor key
↑
or
↓
.
Clamp width
The width of the clamp pulse can be any value between 0 and 255. Change the value by pushing
the cursor key
↑
or
↓
.
Sync
pulse
Clamp
pulse
Clamp
delay
Clamp
width
Le
a
d
ing e
dge
Tr
a
ilinging e
dge
Image 5-1
Example for
Clamp position
[trailing]
Field polarity
The field polarity function is used for interlaced images. Both rasters of the image could be shifted in a
wrong way (double lines are visible in the image). This can be corrected by forcing the field polarity to
[neg] or [pos]. Use the
ENTER
key to toggle between [pos] and [neg].
40
R5976420 BARCOREALITY SIM 6 ULTRA 14052003