16
UNILUX-3 200 L / 200 R / 300
3.3.2. Fitting in an existing chimney breast
• Remove the existing fi re basket or stoking stones and remove the shut-off
fl ap. The chimney must be intact and must not be damaged during fi tting. The
chimney breast opening must be big enough for a gap of 1 - 3 cm to be left all
round the appliance.
Clad, if possible, the chimney breast opening from the inside with a ceramic
wool fi reblanket or similar (see section 3.3).
• Extend the existing chimney so that it ends at the appliance’s smoke outlet.
To do this, use a fl exible, double-walled stainless steel chimney, for example.
• Slide the appliance into the chimney breast opening. Seal the smoke
outlet where it joins the chimney so that no soot can accumulate above the
appliance
under any circumstances
.
• Use the four adjustable legs to set the height of the appliance and level off.
These adjustable legs can be reached after the bottom plates have been
removed.
See section 11 for the disassembly sequence: “Sequence for replacing the
interior of the appliance”.
• Fill any gaps around the appliance with a ceramic insulation wool fi reblanket
(see section 3.3).
• Plaster the walls till ± 2 mm around the appliance.
Use the “built-in frame” (accessorie) if possible. (See section 2.3.)
Summary of Contents for UNILUX-3200 L
Page 2: ......
Page 3: ...3 UNILUX 3 200 L 200 R 300 UNILUX 3 200 R ...
Page 4: ...4 UNILUX 3 200 L 200 R 300 ...
Page 6: ...6 UNILUX 3 200 L 200 R 300 ...
Page 40: ...40 UNILUX 3 200 L 200 R 300 Remove the side internal panel Remove the rear internal panel ...
Page 42: ...42 UNILUX 3 200 L 200 R 300 12 DIMENSIONS 12 1 UNILUX 3 200 L ...
Page 43: ...43 UNILUX 3 200 L 200 R 300 12 2 UNILUX 3 200 R ...
Page 44: ...44 UNILUX 3 200 L 200 R 300 12 3 UNILUX 3 300 ...
Page 49: ...49 UNILUX 3 200 L 200 R 300 ...
Page 50: ...50 UNILUX 3 200 L 200 R 300 ...
Page 51: ......