21
EVO 80-65
Installation instructions
Place the included collar adapter in the air intake opening.
Construct a direct combustion air supply from the outside by means of a metal (fl exible)
tube (125 mm) and a grate on the outer wall.
Only replace the door in the appliance after fi tting the complete appliance.
2.2.8 The casing / fi replace
• The casing may not be directly connected to the built-in fi re, but must be
constructed so that it is self-supporting; a mantle iron or lintel should be used for this.
The covering in the area must be of non-fl ammable materials of fl ame-retardant
material class A1. This includes bricks, cladding, ceramic tiles, metal or plasterwork,
Promatec and Nobranda.
• The opening for incoming and outgoing air from the casing must be at least totally
900 cm². At least 200 cm² from the opening for incoming and outgoing air must not
be closable. The ventilation of the casing/fi replace can be provided by grills, but this
can also be achieved by not building the fi replace right up to the ceiling (leaving a
gap of 5 cm).
• When building in the appliance you can, if you wish, use a convection set (1x or 2x)
(option) to connect the convection openings to the warm air exit grills in the chimney
breast (See also Chapter 2.2.5).
• Built-in fi res must be constructed such that the adapter from the chimney and
convection pipes can easily be cleaned.
• There must be no electrical cables or gas pipes in the walls surrounding the area of
the fi replace.
Heat-insulating materials
The heat-insulating materials to be used must meet specifi c quality standards.
Manufacturers of insulating materials quote an insulation number on the packaging
consisting of 10 numbers in accordance with the stipulations of AGI-Q132. Only those
insulating materials listed in the adjacent table 1 or alternatives approved (in Germany)
by DIBT may be used.