31
EVO 80-65
Installation instructions
It is essential that the appliance, the chimney and the
combustion air supply are cleaned and inspected
annually, by a Barbas-dealer/expert.
The safe operation of the appliance will thus remain
guaranteed.
4
ANNUAL MAINTENANCE
Start with maintence 24 hours after the last burning period.
Recommended order for yearly maintenance:
Inside the appliance:
• Check the door seals. If necessary, replace the seals.
• Emptying the ashtray.
• Clean the glass on the inside of the door with glass spray or ceramic hob
cleaner.
• If the glass is broken or cracked, it must be immediately replaced before
operating the appliance again.
Broken ceramic heat-resistant glass may not be thrown
away in a glass container, but must be included in
normal household waste.
• Check the grate and all interior plates on cracks.
If necessary, replace the parts.
Chimney / fl ue channel:
• Sweep and inspect chimney. Check for cracks, loose parts, fl ue gas leakage
and overall condition of the chimney.
When in doubt use an inspection camera !
Combustion air supply appliance:
• Check the combustion air supply route from the outside up to the appliance.
• Clean the combustion air supply inlet openings.
Convection air (Ventilation air) appliance:
• Check the convection air route.
• Clean the convection air intake openings, fl ues and air escape openings.
• Clean the innerside of the fan box (option).
The convection fan can be reached after removal of the complete fl oor of the
combustion chamber / heating room.